Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Focussing of momentum entangled photon pairs

Daniel Schlenk, Harald Weinfurter

Published Jun 1, 2009• 0 citations
Publisher

Abstract

The resolution of optical scanning microscopes is limited by the spot size of the scanning beam. It has been proposed that momentum entangled photons can be focused more tightly than classical light. We use a confocal microscope to measure the single and two photon distribution in the focus.
DOI
10.1109/cleoe-eqec.2009.5191628

Related papers

Breaking the diffraction limit using entanglement based microscopy

Daniel Schlenk, Harald Weinfurter

The resolution of optical scanning microscopes is limited by the spot size of the scanning beam. It has been proposed by Boto1 et al. and Nasr2 et al. that momentum entangled photons can be focused more tightly than classical light. Thus they should enable one to break the di ractive resolution limit. We report experiments measuring the spatial distribution of strong focussed momentum entangled photon pairs at a center wavelength of 812 nm from a spontaneous parametric down conversion source. Using a single gold stripe deposited on a glass surface as test object we observe a two-photon spot size as small as 194 nm, thereby beating the di raction limit even for conventional two-photon microscopy.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 26, 2013•1 citation

Entangled-Photon Microscopy

Malvin Carl Teich, Bahaa E. A. Saleh

All forms of microscopy that have previously been developed rely on classical sources of light, which are relatively noisy by virtue of the photons arriving randomly in time and position. We propose a new technique of two-beam optical microscopy using a nonclassical light source comprising entangled photon pairs generated by the process of nonlinear optical parametric downconversion. Entangled-photon microscopy (EPM) has the potential for providing a substantial improvement over confocal laser scanning fluorescence microscopy (CLSM) as well as over two-photon laser scanning fluorescence microscopy (TPLSM). The latter technique relies on the proportionality of the two-photon absorption rate to the square of the optical photon-flux density, and makes use of a highly focused optical beam to localize the region from which fluorescence is observed. However, because the arrival of pairs of photons is accidental in TPLSM, relatively large values of the photon-flux density are required to achieve photon coincidence and hence absorption. This can lead to undesired phototoxicity and photobleaching of the specimen. EPM, in contrast, relies on the presence of highly correlated photon pairs, which enhances the two-photon absorption rate significantly and enables lower values of the photon-flux density to be used. The process depends linearly, rather than quadratically, on the photon-flux density. Further, the EPM interaction region can be controlled by the use of two beams, providing increased flexibility in the selection of desired regions of a specimen, and leading to enhanced axial and lateral resolution.

•Feb 27, 1997•0 citations

Confocal imaging from biphoton correlations

Euan Millar, Emma Pearce, Daniele Faccio +1 more

Confocal microscopy provides optical sectioning for three-dimensional imaging but conventionally relies on point-by-point scanning and physical pinholes, limiting imaging speed. Here, we demonstrate that confocal sectioning can instead arise directly from quantum measurement, using spatial correlations in entangled biphoton states. Spatially resolved coincidence measurements in a widefield imaging system suppress contributions from out-of-focus planes, producing optical sectioning in parallel across the whole field of view without physical pinholes or mechanical scanning. In addition, this quantum approach obtains an axial response that, as a result of position-momentum entanglement, is $\sqrt{2}$-times narrower than that of classical confocal imaging. Our work establishes biphoton correlations as a mechanism for improved confocal imaging and enables parallel, pinhole-free optical sectioning without mechanical scanning.

physics.opticsCross-listedarXiv:2609.39954•Oct 1, 2026•0 citations

Twin-photon confocal microscopy

David S. Simon, Alexander V. Sergienko

A recently introduced two-channel confocal microscope with correlated detection promises up to 50% improvement in transverse spatial resolution [Simon, Sergienko, Optics Express 18, 9765 (2010)] via the use of photon correlations. Here we achieve similar results in a different manner, introducing a triple-confocal correlated microscope which exploits the correlations present in optical parametric amplifiers. It is based on tight focusing of pump radiation onto a thin sample positioned in front of a nonlinear crystal, followed by coincidence detection of signal and idler photons, each focused onto a pinhole. This approach offers further resolution enhancement in confocal microscopy.

arXiv:1005.1576•Optics Express•Oct 5, 2010•12 citations

Twin-Photon Correlated Confocal Microscopy

David S. Simon, Alexander V. Sergienko

We introduce two new devices, the correlation confocal and twin-photon microscopes. Like the standard two-photon confocal microscope, they use spatially-correlated photon pairs to improve lateral resolution, but with the correlation enforced in different manners.

•Jan 1, 2011•0 citations

Imaging with neutral atoms—a new matter‐wave microscope

Markus Koch, Stefan Rehbein, Günter Schmahl +4 more

Matter-wave microscopy can be dated back to 1932 when Max Knoll and Ernst Ruska published the first image obtained with a beam of focussed electrons. In this paper a new step in the development of matter-wave microscopy is presented. We have created an instrument where a focussed beam of neutral, ground-state atoms (helium) is used to image a sample. We present the first 2D images obtained using this new technique. The imaged sample is a free-standing hexagonal copper grating (with a period of about 36 microm and rod thickness of about 8 microm). The images were obtained in transmission mode by scanning the focussed beam, which had a minimum spot size of about 2.0 microm in diameter (full width at half maximum) across the sample. The smallest focus achieved was 1.9 +/- 0.1 microm. The resolution for this experiment was limited by the speed ratio of the atomic beam through the chromatic aberrations of the zone plate that was used to focus. Ultimately the theoretical resolution limit is set by the wavelength of the probing particle. In praxis, the resolution is limited by the source and the focussing optics.

Journal of Microscopy•Dec 17, 2007•93 citations
The resolution of optical scanning microscopes is limited by the spot size of the scanning beam. It has been proposed by Boto1 et al. and Nasr2 et al. that momentum entangled photons can be focused more tightly than classical light. Thus they should enable one to break the di ractive resolution limit. We report experiments measuring the spatial distribution of strong focussed momentum entangled photon pairs at a center wavelength of 812 nm from a spontaneous parametric down conversion source. Using a single gold stripe deposited on a glass surface as test object we observe a two-photon spot size as small as 194 nm, thereby beating the di raction limit even for conventional two-photon microscopy.
All forms of microscopy that have previously been developed rely on classical sources of light, which are relatively noisy by virtue of the photons arriving randomly in time and position. We propose a new technique of two-beam optical microscopy using a nonclassical light source comprising entangled photon pairs generated by the process of nonlinear optical parametric downconversion. Entangled-photon microscopy (EPM) has the potential for providing a substantial improvement over confocal laser scanning fluorescence microscopy (CLSM) as well as over two-photon laser scanning fluorescence microscopy (TPLSM). The latter technique relies on the proportionality of the two-photon absorption rate to the square of the optical photon-flux density, and makes use of a highly focused optical beam to localize the region from which fluorescence is observed. However, because the arrival of pairs of photons is accidental in TPLSM, relatively large values of the photon-flux density are required to achieve photon coincidence and hence absorption. This can lead to undesired phototoxicity and photobleaching of the specimen. EPM, in contrast, relies on the presence of highly correlated photon pairs, which enhances the two-photon absorption rate significantly and enables lower values of the photon-flux density to be used. The process depends linearly, rather than quadratically, on the photon-flux density. Further, the EPM interaction region can be controlled by the use of two beams, providing increased flexibility in the selection of desired regions of a specimen, and leading to enhanced axial and lateral resolution.
Confocal microscopy provides optical sectioning for three-dimensional imaging but conventionally relies on point-by-point scanning and physical pinholes, limiting imaging speed. Here, we demonstrate that confocal sectioning can instead arise directly from quantum measurement, using spatial correlations in entangled biphoton states. Spatially resolved coincidence measurements in a widefield imaging system suppress contributions from out-of-focus planes, producing optical sectioning in parallel across the whole field of view without physical pinholes or mechanical scanning. In addition, this quantum approach obtains an axial response that, as a result of position-momentum entanglement, is 2\sqrt{2}2​-times narrower than that of classical confocal imaging. Our work establishes biphoton correlations as a mechanism for improved confocal imaging and enables parallel, pinhole-free optical sectioning without mechanical scanning.
A recently introduced two-channel confocal microscope with correlated detection promises up to 50% improvement in transverse spatial resolution [Simon, Sergienko, Optics Express 18, 9765 (2010)] via the use of photon correlations. Here we achieve similar results in a different manner, introducing a triple-confocal correlated microscope which exploits the correlations present in optical parametric amplifiers. It is based on tight focusing of pump radiation onto a thin sample positioned in front of a nonlinear crystal, followed by coincidence detection of signal and idler photons, each focused onto a pinhole. This approach offers further resolution enhancement in confocal microscopy.
Matter-wave microscopy can be dated back to 1932 when Max Knoll and Ernst Ruska published the first image obtained with a beam of focussed electrons. In this paper a new step in the development of matter-wave microscopy is presented. We have created an instrument where a focussed beam of neutral, ground-state atoms (helium) is used to image a sample. We present the first 2D images obtained using this new technique. The imaged sample is a free-standing hexagonal copper grating (with a period of about 36 microm and rod thickness of about 8 microm). The images were obtained in transmission mode by scanning the focussed beam, which had a minimum spot size of about 2.0 microm in diameter (full width at half maximum) across the sample. The smallest focus achieved was 1.9 +/- 0.1 microm. The resolution for this experiment was limited by the speed ratio of the atomic beam through the chromatic aberrations of the zone plate that was used to focus. Ultimately the theoretical resolution limit is set by the wavelength of the probing particle. In praxis, the resolution is limited by the source and the focussing optics.