Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Intensity dependence of the normalized intensity correlation function in parametric down-conversion

Stephen R. Friberg, C.K. Hong, L. Mandeļ

Published Jul 1, 1985• 41 citations
Publisher
DOI
10.1016/0030-4018(85)90361-x

Related papers

Spatial correlations in parametric down-conversion

Stephen Patrick Walborn, Carlos Henrique Monken, Sebastião Pádua +1 more

arXiv:1010.1236•Physics Reports•Jul 7, 2010•402 citations

Spectral and temporal properties of type-II parametric down-conversion: The impact of losses during state generation

Denis A. Kopylov, Michael Stefszky, Torsten Meier +2 more

In this paper, we theoretically study the spectral and temporal properties of pulsed spontaneous parametric down-conversion (SPDC) generated in lossy waveguides. Our theoretical approach is based on the formalism of Gaussian states and the Langevin equation, which is elaborated for weak parametric down-conversion and photon-number-unresolved click detection. Using the example of frequency-degenerate type-II SPDC generated under the pump-idler group-velocity-matching condition, we show how the joint-spectral intensity, mode structure, normalized second-order correlation function, and Hong-Ou-Mandel interference pattern depend on internal losses of the SPDC process. We found that the joint-spectral intensity is almost insensitive to internal losses, while the second-order correlation function shows a strong dependence on them, being different for the signal and idler beams in the presence of internal losses. Based on the sensitivity of the normalized second-order correlation function, we show how its measurement can be used to experimentally determine internal losses.

arXiv:2501.08917•Physical Review Research•Jun 18, 2025•4 citations

Multiphoton correlations in parametric down-conversion and their measurement in the pulsed regime

Olga Aleksandrovna Ivanova, T. Sh. Iskhakov, Alexander N. Penin +1 more

We consider normalised intensity correlation functions (CFs) of different orders for light emitted via parametric down-conversion (PDC) and their dependence on the number of photons per mode. The main problem in measuring such correlation functions is their extremely small width, which considerably reduces their contrast. It is shown that if the radiation under study is modulated by a periodic sequence of pulses that are short compared to the CF width, no decrease in the contrast occurs. A procedure is proposed for measuring normalised CFs of various orders in the pulsed regime. For nanosecond-pulsed PDC radiation, normalised second-order CF is measured experimentally as a function of the mean photon number.

Quantum Electronics•Oct 31, 2006•62 citations

Investigation of Two-Photon Correlation Effects in Parametric Down-Conversion

Chung Ki Hong

•Jan 1, 1988•0 citations

Photon Correlations and interference in type-1 optical parametric down-conversion

Sarben Sarkar, R. A. Andrews, E R Pike

•Jan 1, 1999•0 citations

Three-photon entanglement in structured χ(2) media

T. V. Gevorgyan, Gagik Yu. Kryuchkyan

We investigate production of three-photon states in cascaded parametric down-conversion (PDC). The analysis includes preparation of Greenberger-Horne-Zeilinger polarization-entangled states in cascaded type-II and type-I PDC in the framework of considering the dual-grid structure that involves two periodically poled crystals. Considering cascaded optical parametric oscillator (OPO) driven by a sequence of laser pulses with Gaussian time-dependent envelopes, we investigate quantum statistical properties of high intensity mode generated in intracavity three-photon splitting. Calculating the normalized third-order correlation function below-and at the generation threshold, we demonstrate that in the pulsed regime, depending on the duration of pulses and the time-interval separations between them, the degree of three-photon-number correlation essentially exceed the analogous one for the case of continuous pumping.

Photonics and Micro- and Nano-structured Materials•Jan 20, 2012•0 citations
In this paper, we theoretically study the spectral and temporal properties of pulsed spontaneous parametric down-conversion (SPDC) generated in lossy waveguides. Our theoretical approach is based on the formalism of Gaussian states and the Langevin equation, which is elaborated for weak parametric down-conversion and photon-number-unresolved click detection. Using the example of frequency-degenerate type-II SPDC generated under the pump-idler group-velocity-matching condition, we show how the joint-spectral intensity, mode structure, normalized second-order correlation function, and Hong-Ou-Mandel interference pattern depend on internal losses of the SPDC process. We found that the joint-spectral intensity is almost insensitive to internal losses, while the second-order correlation function shows a strong dependence on them, being different for the signal and idler beams in the presence of internal losses. Based on the sensitivity of the normalized second-order correlation function, we show how its measurement can be used to experimentally determine internal losses.
We consider normalised intensity correlation functions (CFs) of different orders for light emitted via parametric down-conversion (PDC) and their dependence on the number of photons per mode. The main problem in measuring such correlation functions is their extremely small width, which considerably reduces their contrast. It is shown that if the radiation under study is modulated by a periodic sequence of pulses that are short compared to the CF width, no decrease in the contrast occurs. A procedure is proposed for measuring normalised CFs of various orders in the pulsed regime. For nanosecond-pulsed PDC radiation, normalised second-order CF is measured experimentally as a function of the mean photon number.
We investigate production of three-photon states in cascaded parametric down-conversion (PDC). The analysis includes preparation of Greenberger-Horne-Zeilinger polarization-entangled states in cascaded type-II and type-I PDC in the framework of considering the dual-grid structure that involves two periodically poled crystals. Considering cascaded optical parametric oscillator (OPO) driven by a sequence of laser pulses with Gaussian time-dependent envelopes, we investigate quantum statistical properties of high intensity mode generated in intracavity three-photon splitting. Calculating the normalized third-order correlation function below-and at the generation threshold, we demonstrate that in the pulsed regime, depending on the duration of pulses and the time-interval separations between them, the degree of three-photon-number correlation essentially exceed the analogous one for the case of continuous pumping.