Physical Review Letters

High-sensitivity magnetometer based on index-enhanced media

Marlan O. Scully, Michael Fleischhauer

Published Aug 31, 1992• 344 citations
Publisher

Abstract

The large dispersion of a phase-coherent medium, at a point of vanishing absorption, is applied to interferometric measurements of detuning between atomic and radiation frequencies. It is shown that, under certain conditions, the interferometer quantum-limited operation is determined by vacuum-fluctuation shot noise while the noise introduced by the interaction of the probe field with the phase-coherent atoms can be made negligible. As a possible application, an optical magnetometer is analyzed whose sensitivity is shown to be potentially superior to the present state-of-the-art devices.

DOI
10.1103/physrevlett.69.1360

Related papers

Quantum sensitivity limits of an optical magnetometer based on atomic phase coherence

Michael Fleischhauer, Marlan O. Scully

An optical magnetometer based on atomic coherence effects is analyzed using a quantum Langevin approach. The large dispersion of a phase-coherent atomic medium (``phaseonium'') at a point of vanishing absorption is used to detect magnetic level shifts via optical phase measurements in a Mach-Zehnder interferometer with sensitivities potentially superior to state-of-the-art devices. Effects of Doppler broadening and fluctuations of the driving field are discussed and a comparison to standard optical-pumping magnetometers is made.

Physical Review A•Mar 1, 1994•142 citations

A phaseonium magnetometer: A new optical magnetometer based on index enhanced media

Marlan O. Scully, Michael D. Fleischauer, M. B. Graf

An optical magnetometer based on quantum coherence and interference effects in atoms is proposed. The sensitivity of this device is potentially superior to the present state-of-the-art devices. Optimum operating conditions are derived, and a comparison to standard optical pumping magnetometers is made.

•Jan 1, 1993•0 citations

Magnetometer based on atomic coherence and possible application to the search for P and T violating permanent electric dipole moments of atoms

Michael Fleischhauer, Marlan O. Scully

A new approach to the experimental search for P and T violating permanent electric dipole moments (EDMs) in atoms is proposed. The high dispersion of a phase coherent atomic medium at a point of electromagnetically induced transparency is used to detect linear Stark-shifts associated with an atomic EDM in a highly sensitive interferometric measurement. Possible noise sources are analysed and estimates are given for the device sensitivity.

Quantum and Semiclassical Optics Journal of the European Optical Society Part B•Jun 1, 1995•11 citations

High-Sensitivity Quantum-Enhanced Interferometers

Juan Li Yu, Yinhua Wu, Liang Nie +1 more

High-sensitivity interferometers are one of the basic tools for precision measurement, and their sensitivity is limited by their shot noise limit (SNL), which is determined by vacuum fluctuations of the probe field. The quantum interferometer with novel structures can break the SNL and measure the weak signals, such as the direct observation of gravity wave signal. Combining classical interferometers and the optical parametric amplifier (OPA) can enhance the signal; meanwhile, the quantum noise is kept at the vacuum level, so that the sensitivity of the nonlinear interferometer beyond the SNL can be achieved. By analyzing in detail the influence of system parameters on the precision of quantum metrology, including the intensity of optical fields for phase sensing, the gain factor of OPA, and the losses inside and outside the interferometers, the application conditions of high-sensitivity nonlinear quantum interferometers are obtained. Quantum interferometer-based OPAs provide the direct references for the practical development of quantum precise measurement.

Photonics•Jun 29, 2023•2 citations

Experimental light-squeezing-enhanced magnetometry

Alessandro Ceré, Florian Wolfgramm, Federica A. Beduini +3 more

The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•May 1, 2011•0 citations

Radio-frequency atomic magnetometers: an analysis of interrogation regimes

Jenelle Rajroop

An atomic magnetometer is a sensor which is used to measure a magnetic field through its interaction with the atomic sample. Significant research into atomic magnetometry has led to the development of very sensitive atomic sensors capable of matching the sensitivity of the most sensitive magnetometers, superconducting quantum interference devices (SQUIDs). Because SQUIDS require cryogenics to operate, atomic magnetometers provide a sensitive, yet low-cost alternative. They have found use in many areas such as medicine, security, explosives detection and fundamental physics research. One of the primary factors influencing sensitivity is the detuning of the probe beam from the resonant transitions of the atomic ground state. A caesium room temperature radio-frequency (rf) magnetometer is constructed and used to investigate the influence of the probe beam detuning on the magnetometer signal of the F = 3 and F = 4 ground states. The results of probing near and far from resonance revealed an off-resonant regime and two absorptive regimes. In the off-resonant regime, the atomic spins are unperturbed by the probe beam; it is a quantum non-demolition (QND) interaction. The two absorptive regimes, found when the probe beam is in the vicinity of either the 62S1 2 F = 3 → 6 2P3 2 F 0 = 2,3,4 or the 62S1 2 F = 4 → 6 2P3 2 F 0 = 3,4,5 transitions, is characterised as a non-QND interaction in which the probe beam influences the measurement. The sensitivity of the rf magnetometer is determined to be ≈ 1.98 fT/ √ Hz. In addition, the exploration of the relationship between the signal to noise ratio (SNR) and probe beam detuning revealed that the SNR is constant with detuning but the larger the detuning, the higher the probe beam power needs to be to reach the optimum SNR.

•Jun 28, 2018•0 citations
The large dispersion of a phase-coherent medium, at a point of vanishing absorption, is applied to interferometric measurements of detuning between atomic and radiation frequencies. It is shown that, under certain conditions, the interferometer quantum-limited operation is determined by vacuum-fluctuation shot noise while the noise introduced by the interaction of the probe field with the phase-coherent atoms can be made negligible. As a possible application, an optical magnetometer is analyzed whose sensitivity is shown to be potentially superior to the present state-of-the-art devices.
An optical magnetometer based on atomic coherence effects is analyzed using a quantum Langevin approach. The large dispersion of a phase-coherent atomic medium (``phaseonium'') at a point of vanishing absorption is used to detect magnetic level shifts via optical phase measurements in a Mach-Zehnder interferometer with sensitivities potentially superior to state-of-the-art devices. Effects of Doppler broadening and fluctuations of the driving field are discussed and a comparison to standard optical-pumping magnetometers is made.
High-sensitivity interferometers are one of the basic tools for precision measurement, and their sensitivity is limited by their shot noise limit (SNL), which is determined by vacuum fluctuations of the probe field. The quantum interferometer with novel structures can break the SNL and measure the weak signals, such as the direct observation of gravity wave signal. Combining classical interferometers and the optical parametric amplifier (OPA) can enhance the signal; meanwhile, the quantum noise is kept at the vacuum level, so that the sensitivity of the nonlinear interferometer beyond the SNL can be achieved. By analyzing in detail the influence of system parameters on the precision of quantum metrology, including the intensity of optical fields for phase sensing, the gain factor of OPA, and the losses inside and outside the interferometers, the application conditions of high-sensitivity nonlinear quantum interferometers are obtained. Quantum interferometer-based OPAs provide the direct references for the practical development of quantum precise measurement.
The ability to measure magnetic fields with high sensitivity is a key requirement in many physical, biological and medical applications. Currently the most sensitive magnetometers are optical magnetometers, in which the polarization of an atomic sample responds to the field and is read out by an optical measurement. These instruments are limited by two fundamental sources of quantum noise: projection noise of the atoms and shot noise of the light. For magnetometers designed to have a high statistical sensitivity, contributions from both sources are comparable. Here we show that the sensitivity can be improved by the application of non-classical light.
An atomic magnetometer is a sensor which is used to measure a magnetic field through its interaction with the atomic sample. Significant research into atomic magnetometry has led to the development of very sensitive atomic sensors capable of matching the sensitivity of the most sensitive magnetometers, superconducting quantum interference devices (SQUIDs). Because SQUIDS require cryogenics to operate, atomic magnetometers provide a sensitive, yet low-cost alternative. They have found use in many areas such as medicine, security, explosives detection and fundamental physics research. One of the primary factors influencing sensitivity is the detuning of the probe beam from the resonant transitions of the atomic ground state. A caesium room temperature radio-frequency (rf) magnetometer is constructed and used to investigate the influence of the probe beam detuning on the magnetometer signal of the F = 3 and F = 4 ground states. The results of probing near and far from resonance revealed an off-resonant regime and two absorptive regimes. In the off-resonant regime, the atomic spins are unperturbed by the probe beam; it is a quantum non-demolition (QND) interaction. The two absorptive regimes, found when the probe beam is in the vicinity of either the 62S1 2 F = 3 → 6 2P3 2 F 0 = 2,3,4 or the 62S1 2 F = 4 → 6 2P3 2 F 0 = 3,4,5 transitions, is characterised as a non-QND interaction in which the probe beam influences the measurement. The sensitivity of the rf magnetometer is determined to be ≈ 1.98 fT/ √ Hz. In addition, the exploration of the relationship between the signal to noise ratio (SNR) and probe beam detuning revealed that the SNR is constant with detuning but the larger the detuning, the higher the probe beam power needs to be to reach the optimum SNR.