Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Optimum realization of the EPR paradox in the non-degenerate parametric amplification system

Chao Zhao, W. H. Tan

Published Dec 15, 2006• 12 citations
Publisher

Abstract

The solution of the Fokker–Planck equation is used here for non-degenerate parametric amplification to deduce the condition of demonstration of the EPR paradox. Numerical calculations show that the optimum realization of the EPR paradox can be achieved by adjusting the degree of squeezing for a certain finite loss k.
DOI
10.1080/09500340600879270

Related papers

Optimum realization of the EPR paradox in the non-degenerate parametric amplification system

Chao Zhao, TAN WEI-HAN, 上海大学物理系,上海 200444

In this paper, we use the solution of the Fokker-Planck equation for non-degenerate parametric amplification to deduce the condition of demonstration of the EPR paradox. The numerical simulation shows that the optimum realization of EPR paradox can be achieved by adjusting the degree of squeezing, and this is the best condition for demonstrating the EPR paradox for a given finite loss k.

Acta Physica Sinica•Jan 1, 2006•2 citations

The solution of the time-dependent Fokker–Planck equation of non-degenerate optical parametric amplification and its application to the optimum realization of EPR paradox

Chao Zhao, TAN WEI-HAN

In this paper, the solution of the time-dependent Fokker–Planck equation of non-degenerate optical parametric amplification is used to deduce the condition demonstrating the Einstein–Podolsky–Rosen (EPR) paradox. The analytics and numerical calculation show the influence of pump depletion on the error in the measurement of continuous variables. The optimum realization of EPR paradox can be achieved by adjusting the parameter of squeezing. This result is of practical importance when the realistic experimental conditions are taken into consideration.

Chinese Physics•Feb 26, 2007•7 citations

Influence of Pump Depletion of Non-degenerate Optical Parametric Amplification on the Optimum Realization of EPR Paradox

Chaoying, Zhao, Weihan +1 more

量子光学学报•Jan 1, 2006•0 citations

The solution of the Fokker-Planck equation of non-degenerate parametric amplific ation system for generation of squeezed light

Chao Zhao, TAN WEI-HAN, Qizhi Guo +1 more

In this paper, we present the analytical solution of the Fokker-Planck equation of non-degenerate optical parametric amplification(NOPA)for generation of squeezed light. The maximum intra-cavity compression of squeezed light derived from the analytical solution is 1/16(vacuum fluctuations 1/4). To compare it with that of the previous result 1/8 of degenerate optical parametric amplification(DOPA), it seems that the squeezing for NOPA is superior to the squeezing for DOPA.

Acta Physica Sinica•Jan 1, 2003•9 citations

Realization of the Einstein-Podolsky-Rosen paradox with a nondegenerate parametric amplifier

Z. Y. Ou, Silvania F. Pereira, Kaidong Peng +1 more

Over the past three decades, numerous demonstrations of the violation of Bell’s inequalities have been reported in optical experiments based upon observations of polarization correlations for photon pairs. Without exception, these measurements as well as those in other systems have involved discrete variables for which the Bell inequalities are applicable. By contrast, an experiment to demonstrate the original proposal by Einstein, Podolsky, and Rosen (EPR)1 for a system of observables with a continuous spectrum has not previously been realized. From many possible theoretical avenues, we have followed the suggestion of Reid and Drummond2 to achieve a demonstration of the EPR paradox for continuous variables by employing a subthreshold optical parametric oscillator (OPO) operated in a frequency-degenerate but polarization-nondegenerate mode.

Quantum Electronics and Laser Science Conference•May 10, 1992•0 citations

Quantum fluctuations of the optical parametric amplification system under the consideration of dispersion

Chao Zhao, TAN WEI-HAN, (1)杭州电子科技大学理学院,杭州 310018;山西大学光电研究所,量子光学与光量子器件国家重点实验室,太原 030006; (2)上海大学物理系,上海 200444

In this paper, we first find out the analytic solution of the time-dependent Fokker-Planck equation of the non-degenerate optical parametric amplification (NOPA) system under the consideration of the dispersion, the loss and the pump depletion effects. Then, through the numerical calculation, we obtain the squeezing characteristic of the degenerate optical parametric amplification (DOPA) system with dispersion. the research indicates: the dispersion effect stems from the nonlinear susceptibility change from χ″ toχ″/{1+σ2/}/+2, with the increasing of the dispersion effect, the general feature of the squeezing curves beeps unchanged, and the curves contract toward left. The maximum squeezing approaches to the linear theory 1/(1+μ). Finally, we obtain the entanglement characteristic of the NOPA system with dispersion. We find out when σ is given, with the increasing of pump parameter μ, he corresponding phase makes a large change. The nonlinear susceptibility changes many times. When the polarity is positive, the system obtains the gain, when the polarity is negative, the system suffers the loss, but the gain is mainly dissipated by the loss, so the net gain is small, the squeezing is also small. The minimum variance V1 reduces gradually, and the whole curve moves to the right, approaches to the linear theory 1/(1+μ).

Acta Physica Sinica•Jan 1, 2010•0 citations
In this paper, the solution of the time-dependent Fokker–Planck equation of non-degenerate optical parametric amplification is used to deduce the condition demonstrating the Einstein–Podolsky–Rosen (EPR) paradox. The analytics and numerical calculation show the influence of pump depletion on the error in the measurement of continuous variables. The optimum realization of EPR paradox can be achieved by adjusting the parameter of squeezing. This result is of practical importance when the realistic experimental conditions are taken into consideration.
Over the past three decades, numerous demonstrations of the violation of Bell’s inequalities have been reported in optical experiments based upon observations of polarization correlations for photon pairs. Without exception, these measurements as well as those in other systems have involved discrete variables for which the Bell inequalities are applicable. By contrast, an experiment to demonstrate the original proposal by Einstein, Podolsky, and Rosen (EPR)1 for a system of observables with a continuous spectrum has not previously been realized. From many possible theoretical avenues, we have followed the suggestion of Reid and Drummond2 to achieve a demonstration of the EPR paradox for continuous variables by employing a subthreshold optical parametric oscillator (OPO) operated in a frequency-degenerate but polarization-nondegenerate mode.
In this paper, we first find out the analytic solution of the time-dependent Fokker-Planck equation of the non-degenerate optical parametric amplification (NOPA) system under the consideration of the dispersion, the loss and the pump depletion effects. Then, through the numerical calculation, we obtain the squeezing characteristic of the degenerate optical parametric amplification (DOPA) system with dispersion. the research indicates: the dispersion effect stems from the nonlinear susceptibility change from χ″ toχ″/{1+σ2/}/+2, with the increasing of the dispersion effect, the general feature of the squeezing curves beeps unchanged, and the curves contract toward left. The maximum squeezing approaches to the linear theory 1/(1+μ). Finally, we obtain the entanglement characteristic of the NOPA system with dispersion. We find out when σ is given, with the increasing of pump parameter μ, he corresponding phase makes a large change. The nonlinear susceptibility changes many times. When the polarity is positive, the system obtains the gain, when the polarity is negative, the system suffers the loss, but the gain is mainly dissipated by the loss, so the net gain is small, the squeezing is also small. The minimum variance V1 reduces gradually, and the whole curve moves to the right, approaches to the linear theory 1/(1+μ).