Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Letters

Ultrahigh-contrast imaging by temporally modulated stimulated emission depletion

Lyubov V. Amitonova, И. В. Федотов, Aleksei M. Zheltikov

Published Feb 13, 2015• 16 citations
Publisher

Abstract

Stimulated emission depletion (STED) is the key optical technology enabling super-resolution microscopy below the diffraction limit. Here, we demonstrate that modulation of STED in the time domain, combined with properly designed lock-in detection, can radically enhance the contrast of fluorescent images of strongly autofluorescent biotissues. In our experiments, the temporally modulated STED technique, implemented with low-intensity continuous-wave laser sources, is shown to provide an efficient all-optical suppression of a broadband fluorescent background, allowing the contrast of fluorescent images of mammal brain tissues tagged with nitrogen-vacancy diamond to be increased by five orders of magnitude.

DOI
10.1364/ol.40.000725

Related papers

Super-resolution microscopy enabled by high-efficiency surface-migration emission depletion

Rui Pu, Qiuqiang Zhan, Xingyun Peng +6 more

Abstract Nonlinear depletion of fluorescence states by stimulated emission constitutes the basis of stimulated emission depletion (STED) microscopy. Despite significant efforts over the past decade, achieving super-resolution at low saturation intensities by STED remains a major technical challenge. By harnessing the surface quenching effect in NaGdF 4 :Yb/Tm nanocrystals, we report here high-efficiency emission depletion through surface migration. Using a dual-beam, continuous-wave laser manipulation scheme (975-nm excitation and 730-nm de-excitation), we achieved an emission depletion efficiency of over 95% and a low saturation intensity of 18.3 kW cm −2 . Emission depletion by surface migration through gadolinium sublattices enables super-resolution imaging with sub-20 nm lateral resolution. Our approach circumvents the fundamental limitation of high-intensity STED microscopy, providing autofluorescence-free, re-excitation-background-free imaging with a saturation intensity over three orders of magnitude lower than conventional fluorophores. We also demonstrated super-resolution imaging of actin filaments in Hela cells labeled with 8-nm nanoparticles. Combined with the highly photostable lanthanide luminescence, surface-migration emission depletion (SMED) could provide a powerful mechanism for low-power, super-resolution imaging or biological tracking as well as super-resolved optical sensing/writing and lithography.

Nature Communications•Nov 4, 2022•48 citations

Temporal characteristic simulation for stimulated emission depletion microscopy

Chen Wen-xia, Fanrong Xiao, Li Liu +1 more

The imaging technology of stimulated emission depletion (STED) utilizes the nonlinearity relationship between the fluorescence saturation and the excited state stimulated depletion. It implements three-dimensional (3D) imaging and breaks the diffraction barrier of far-field light microscopy by restricting fluorescent molecules at a sub-diffraction spot. In order to improve the resolution which attained by this technology, the computer simulation on temporal behavior of population probabilities of the sample was made in this paper, and the optimized parameters such as intensity, duration and delay time of the STED pulse were given.

Chinese Optics Letters•Aug 28, 2005•0 citations

Three-Dimensional Stimulated Emission Depletion Microscopy of Nitrogen-Vacancy Centers in Diamond Using Continuous-Wave Light

Kyu Young Han, Katrin I. Willig, Eva Rittweger +3 more

Charged nitrogen-vacancy (NV) color centers in diamond are excellent luminescence sources for far-field fluorescence nanoscopy by stimulated emission depletion (STED). Here we show that these photostable color centers can be visualized by STED using simple continuous-wave or high repetition pulsed lasers (76 MHz) at wavelengths >700 nm for STED. Furthermore, we show that NV centers can be imaged in three dimensions (3D) inside the diamond crystal and present single-photon signatures of single color centers recorded in high density samples, demonstrating a new recording scheme for STED and related far-field nanoscopy approaches. Finally, we exemplify the potential of using nanodiamonds containing NV centers as luminescence tags in STED microscopy. Our results offer new experimental avenues in nanooptics, nanotechnology, and the life sciences.

Nano Letters•Jul 27, 2009•178 citations

STED imaging of green fluorescent nanodiamonds containing nitrogen-vacancy-nitrogen centers

Grégoire Laporte, Demetri Psaltis

We report Stimulated Emission Depletion (STED) imaging of green fluorescent nanodiamonds containing Nitrogen-acancy-Nitrogen (NVN) centers with a resolution of 70 nm using a commercial microscope. Nanodiamonds have been demonstrated to have the potential to be excellent cellular biomarkers thanks to their low toxicity and nonbleaching fluorescence, and are especially appealing for superresolution imaging technique like STED microscopy. However, only red fluorescent nanodiamonds containing Nitrogen-Vacancy (NV) centers have been used with STED microscopy so far. The existence of only one color nonbleaching center limits the possible observations, for instance it complicates spatial correlation studies with STED. To provide a nonbleaching probe in a different color, we characterize here the optical properties of the NVN defect for STED imaging. We demonstrate STED imaging of the green fluorescent nanodiamonds containing NVN centers, opening the door for long term two-color STED observation. Furthermore we exemplify the use of green nanodiamonds as a second color nonbleaching STED biomarker by imaging 70 nm fluorescent crystals up taken into HeLa cells.

Biomedical Optics Express•Dec 7, 2015•45 citations

Stimulated emission depletion microscopy with diamond silicon-vacancy centers

Yaser Silani, Forrest Hubert, Víctor M. Acosta

The spatial resolution and fluorescence signal amplitude in stimulated emission depletion (STED) microscopy is limited by the photostability of available fluorophores. Here, we show that negatively-charged silicon vacancy (SiV) centers in diamond are promising fluorophores for STED microscopy, owing to their photostable, near-infrared emission and favorable photophysical properties. A home-built pulsed STED microscope was used to image shallow implanted SiV centers in bulk diamond at room temperature. The SiV stimulated emission cross section for 765-800 nm light is found to be (4.0 ± 0.3)×10^−17 cm^2, which is approximately 2-4 times larger than that of the negatively-charged diamond nitrogen vacancy center and approaches that of commonly-used organic dye molecules. We performed STED microscopy on isolated SiV centers and observed a lateral full-width-at-half- maximum spot size of 89 ± 2 nm, limited by the low available STED laser pulse energy (0.4 nJ). For a pulse energy of 5 nJ, the resolution is expected to be ∼20 nm. We show that the present microscope can resolve SiV centers separated by �� < 150 nm that cannot be resolved by confocal microscopy.

•Nov 7, 2019•19 citations

Nanosecond super-resolved imaging of a single cold atom by stimulated emission depletion microscopy

Zhong-Hua Qian, Jin‐Ming Cui, Xi-Wang Luo +6 more

As one of the most critical methods for optical super-resolved microscopy, stimulated emission depletion (STED) microscopy has been widely applied in biological and chemical fields, leading to the Nobel prize of 2014 in chemistry. In cold atomic systems, fast and high-resolution microscopy of individual atoms is crucial since it can provide direct information on the dynamics and correlations of the system. Here, we demonstrate nanosecond two-dimensional snapshots of a single trapped ion beyond the optical diffraction limit, by combining the main idea of STED with the quantum state transition control in cold atoms. We achieve a spatial resolution up to 175 nm and a time resolution up to 50 ns simultaneously using a NA=0.1 objective in the experiment, which is improved over ten times compared to direct fluorescence imaging. To show the potential of this method, we applied it to record the motion of the trapped ion and observe one cycle of the secular motion of the ion with a displacement detection sensitivity of 10 nm. Our method provides a powerful tool for probing particles' positions, momenta and correlations, as well as their dynamics in cold atomic systems.

•Apr 20, 2021•1 citation
Stimulated emission depletion (STED) is the key optical technology enabling super-resolution microscopy below the diffraction limit. Here, we demonstrate that modulation of STED in the time domain, combined with properly designed lock-in detection, can radically enhance the contrast of fluorescent images of strongly autofluorescent biotissues. In our experiments, the temporally modulated STED technique, implemented with low-intensity continuous-wave laser sources, is shown to provide an efficient all-optical suppression of a broadband fluorescent background, allowing the contrast of fluorescent images of mammal brain tissues tagged with nitrogen-vacancy diamond to be increased by five orders of magnitude.
Abstract Nonlinear depletion of fluorescence states by stimulated emission constitutes the basis of stimulated emission depletion (STED) microscopy. Despite significant efforts over the past decade, achieving super-resolution at low saturation intensities by STED remains a major technical challenge. By harnessing the surface quenching effect in NaGdF 4 :Yb/Tm nanocrystals, we report here high-efficiency emission depletion through surface migration. Using a dual-beam, continuous-wave laser manipulation scheme (975-nm excitation and 730-nm de-excitation), we achieved an emission depletion efficiency of over 95% and a low saturation intensity of 18.3 kW cm −2 . Emission depletion by surface migration through gadolinium sublattices enables super-resolution imaging with sub-20 nm lateral resolution. Our approach circumvents the fundamental limitation of high-intensity STED microscopy, providing autofluorescence-free, re-excitation-background-free imaging with a saturation intensity over three orders of magnitude lower than conventional fluorophores. We also demonstrated super-resolution imaging of actin filaments in Hela cells labeled with 8-nm nanoparticles. Combined with the highly photostable lanthanide luminescence, surface-migration emission depletion (SMED) could provide a powerful mechanism for low-power, super-resolution imaging or biological tracking as well as super-resolved optical sensing/writing and lithography.
The imaging technology of stimulated emission depletion (STED) utilizes the nonlinearity relationship between the fluorescence saturation and the excited state stimulated depletion. It implements three-dimensional (3D) imaging and breaks the diffraction barrier of far-field light microscopy by restricting fluorescent molecules at a sub-diffraction spot. In order to improve the resolution which attained by this technology, the computer simulation on temporal behavior of population probabilities of the sample was made in this paper, and the optimized parameters such as intensity, duration and delay time of the STED pulse were given.
Charged nitrogen-vacancy (NV) color centers in diamond are excellent luminescence sources for far-field fluorescence nanoscopy by stimulated emission depletion (STED). Here we show that these photostable color centers can be visualized by STED using simple continuous-wave or high repetition pulsed lasers (76 MHz) at wavelengths >700 nm for STED. Furthermore, we show that NV centers can be imaged in three dimensions (3D) inside the diamond crystal and present single-photon signatures of single color centers recorded in high density samples, demonstrating a new recording scheme for STED and related far-field nanoscopy approaches. Finally, we exemplify the potential of using nanodiamonds containing NV centers as luminescence tags in STED microscopy. Our results offer new experimental avenues in nanooptics, nanotechnology, and the life sciences.
We report Stimulated Emission Depletion (STED) imaging of green fluorescent nanodiamonds containing Nitrogen-acancy-Nitrogen (NVN) centers with a resolution of 70 nm using a commercial microscope. Nanodiamonds have been demonstrated to have the potential to be excellent cellular biomarkers thanks to their low toxicity and nonbleaching fluorescence, and are especially appealing for superresolution imaging technique like STED microscopy. However, only red fluorescent nanodiamonds containing Nitrogen-Vacancy (NV) centers have been used with STED microscopy so far. The existence of only one color nonbleaching center limits the possible observations, for instance it complicates spatial correlation studies with STED. To provide a nonbleaching probe in a different color, we characterize here the optical properties of the NVN defect for STED imaging. We demonstrate STED imaging of the green fluorescent nanodiamonds containing NVN centers, opening the door for long term two-color STED observation. Furthermore we exemplify the use of green nanodiamonds as a second color nonbleaching STED biomarker by imaging 70 nm fluorescent crystals up taken into HeLa cells.
The spatial resolution and fluorescence signal amplitude in stimulated emission depletion (STED) microscopy is limited by the photostability of available fluorophores. Here, we show that negatively-charged silicon vacancy (SiV) centers in diamond are promising fluorophores for STED microscopy, owing to their photostable, near-infrared emission and favorable photophysical properties. A home-built pulsed STED microscope was used to image shallow implanted SiV centers in bulk diamond at room temperature. The SiV stimulated emission cross section for 765-800 nm light is found to be (4.0 ± 0.3)×10^−17 cm^2, which is approximately 2-4 times larger than that of the negatively-charged diamond nitrogen vacancy center and approaches that of commonly-used organic dye molecules. We performed STED microscopy on isolated SiV centers and observed a lateral full-width-at-half- maximum spot size of 89 ± 2 nm, limited by the low available STED laser pulse energy (0.4 nJ). For a pulse energy of 5 nJ, the resolution is expected to be ∼20 nm. We show that the present microscope can resolve SiV centers separated by �� < 150 nm that cannot be resolved by confocal microscopy.
As one of the most critical methods for optical super-resolved microscopy, stimulated emission depletion (STED) microscopy has been widely applied in biological and chemical fields, leading to the Nobel prize of 2014 in chemistry. In cold atomic systems, fast and high-resolution microscopy of individual atoms is crucial since it can provide direct information on the dynamics and correlations of the system. Here, we demonstrate nanosecond two-dimensional snapshots of a single trapped ion beyond the optical diffraction limit, by combining the main idea of STED with the quantum state transition control in cold atoms. We achieve a spatial resolution up to 175 nm and a time resolution up to 50 ns simultaneously using a NA=0.1 objective in the experiment, which is improved over ten times compared to direct fluorescence imaging. To show the potential of this method, we applied it to record the motion of the trapped ion and observe one cycle of the secular motion of the ion with a displacement detection sensitivity of 10 nm. Our method provides a powerful tool for probing particles' positions, momenta and correlations, as well as their dynamics in cold atomic systems.