Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Modern Optics

Two-level atom in a squeezed vacuum with finite bandwidth

R. Tanaś, Z. Ficek, Azeddine Messikh, Tarek M. El-Shahat

Published Sep 1, 1998• 22 citations
Publisher

Abstract

The resonance fluorescence of a two-level atom driven by a coherent laser field and damped by a finite bandwidth squeezed vacuum is analysed. We extend the Yeoman and Barnett technique to a non-zero detuning of the driving field from the atomic resonance and discuss the role of squeezing bandwidth and the detuning in the level shifts, widths and intensities of the spectral lines. The approach is valid for arbitrary values of the Rabi frequency and detuning but for the squeezing bandwidths larger than the natural line-width in order to satisfy the Markoff approximation. The narrowing of the spectral lines is interpreted in terms of the quadrature-noise spectrum. We find that, depending on the Rabi frequency, detuning and the squeezing phase, different factors contribute to the line narrowing. For a strong resonant driving field there is no squeezing in the emitted field and the fluorescence spectrum exactly reveals the noise spectrum. In this case the narrowing of the spectral lines arises from the noise reduction in the input squeezed vacuum. For a weak or detuned driving field the fluorescence exhibits a large squeezing and, as a consequence, the spectral lines have narrowed linewidths. Moreover, the fluorescence spectrum can be asymmetric about the central frequency despite the symmetrical distribution of the noise. The asymmetry arises from the absorption of photons by the squeezed vacuum which reduces the spontaneous emission. For an appropriate choice of the detuning some of the spectral lines can vanish despite that there is no population trapping. Again this process can be interpreted as arising from the absorption of photons by the squeezed vacuum. When the absorption is large it may compensate the spontaneous emission resulting in the vanishing of the fluorescence lines.

DOI
10.1080/09500349808231707

Related papers

Spectral linewidth narrowing by a narrow bandwidth squeezed vacuum in a cavity

Z. Ficek, Bryan J. Dalton, Mohamed Ridza Wahiddin

The fluorescence spectrum of a strongly driven two-level atom located inside an optical cavity damped by a narrow-bandwidth squeezed vacuum is studied. We use a dressed atom model approach, first applied to squeezed vacuum problems by Yeoman and Barnett, to derive the master equation of the system and discuss the role of the cavity and the squeezed vacuum in the narrowing of the spectral lines and the population trapping effect. We find that in the presence of a single-mode cavity the effect of squeezing on the fluorescence spectrum is more evident in the linewidths of the Rabi sidebands rather than in the linewidth of the central component. Even in the absence of squeezing, the cavity can reduce the linewidth of the central component almost to zero, whereas the Rabi sidebands can be narrowed only to some finite value. In the presence of a two-mode cavity and a two-mode squeezed vacuum the signature of squeezing is evident in the linewidths of all spectral lines. We also establish that the narrowing of the spectral lines is very sensitive to the detuning of the driving field from the atomic resonance. Moreover, we find that the population trapping effect, predicted for the broadband squeezed vacuum case, may appear in a narrow-bandwidth case only if the input squeezed modes are perfectly matched to the cavity modes and if there is non-zero squeezing at the Rabi sidebands.

Journal of Modern Optics•May 1, 1997•16 citations

Two-level atom in a squeezed vacuum

R. Tanaś

The master equation for a two-level atom interacting with a strong coherent field and damped into a reservoir formed by a finite bandwidth squeezed vacuum is derived. The master equation extends the Yeoman and Barnett approach to a non-zero detuning of the driving field from the atomic resonance and allows to discuss the role of squeezing bandwidth and the detuning in the level shifts, widths and intensities of spectral lines. The approach is valid for arbitrary values of the Rabi frequency and detuning but for the squeezing bandwidths larger than the natural linewidth in order to satisfy the Markov approximation.

TURKISH JOURNAL OF PHYSICS•Dec 8, 1999•1 citation

Influence of squeezing bandwidths on resonance fluorescence

Gordon Yeoman, Stephen Mark Barnett

We present an analytical technique for investigating the behaviour of a coherently driven atom damped by a squeezed vacuum with finite squeezing bandwidth. A master equation and analytic expressions for the fluorescent spectrum are derived for the simple case of a two-level atom exactly resonant with the frequencies of both the squeezed field and the driving field. Suitable choices of driving strength, phase and squeezing source lead to either sub-natural lincwidths of the Rabi sidebands or a sub-natural linewidth of the central spectral peak or indeed sub-natural linewidths of all three spectral peaks when squeezing bandwidths are taken into account. We also establish the remarkable result that in the strong driving regime, the width of the central peak of the fluorescent spectrum depends solely on the squeezing found at the Rabi sideband frequencies.

Journal of Modern Optics•Oct 1, 1996•27 citations

Resonance fluorescence of a two-level atom in an off-resonance squeezed vacuum

Z. Ficek, Barry C. Sanders

The authors present analytical and numerical results for resonance fluorescence produced by a two-level atom damped by a broad-band squeezed vacuum. Previous theoretical analyses of this model have assumed that the laser frequency and the carrier frequency of the squeezed vacuum are equal. The authors introduce a non-zero detuning between the laser frequency and the carrier frequency while maintaining resonance between the laser frequency and atomic resonance. In the absence of the driving field there is a squeezing threshold: above threshold the decay rate of the atomic polarization can be reduced, and below threshold a squeezing-induced two peak spectrum and frequency shift, which is analogous to the Bloch-Siegert shift, are predicted. In the presence of the driving field, the spectrum is asymmetric for Rabi frequencies smaller or comparable to the detuning of the squeezed vacuum. A symmetric spectrum is obtained for large Rabi frequencies. An interpretation is predicted by means of a dressed-state analysis. The authors find that for not too large Rabi frequencies a remarkably large population inversion can be induced in the dressed states, even at exact resonance of the driving field, provided that the laser frequency and carrier frequency are detuned. Moreover, for detection times larger than the inverse detuning, the spectrum is insensitive to the phase between the driving field and the squeezed vacuum, in marked contrast to the case of no detuning.

Journal of Physics B Atomic Molecular and Optical Physics•Feb 28, 1994•21 citations

Off-resonant squeezed vacuum effects on a driven two-level atom: absorption and intensity harmonics

Saad S. M. Hassan, O. M. Frege, N. Nayak

The resonance fluorescence system of a coherently driven two-level atom in the presence of a broadband squeezed vacuum field whose central frequency is not in resonance with either the driving field frequency or the atomic transition frequency is analyzed. Solutions of the Bloch equations of the system are presented in terms of continued fractions for arbitrary strength of the coherent driving field. Numerical results are presented for the first-harmonic quadrature components of the absorption spectrum and the fluorescent intensity. The effects of the squeezed vacuum field detuning on the absorption spectrum result in hole burning or a dip structure in the weak-field case and two absorption–amplification peaks in the strong-field case. Results are sensitive to the relative phase of the squeezed vacuum.

Journal of the Optical Society of America B•Jul 1, 1995•14 citations

Phase-dependent fluorescence linewidth narrowing in a three-level atom damped by a finite-bandwidth squeezed vacuum

M. R. Ferguson, Z. Ficek, Bryan J. Dalton

We examine subnatural phase-dependent linewidths in the fluorescence spectrum of a three-level atom damped by a narrow-bandwidth squeezed vacuum in a cavity. Using the dressed-atom model approach of a strongly driven three-level cascade system, we derive the master equation of the system from which we obtain simple analytical expressions for the fluorescence spectrum. We show that the phase effects depend on the bandwidths of the squeezed vacuum and the cavity relative to the Rabi frequency of the driving fields. When the squeezing bandwidth is much larger than the Rabi frequency, the spectrum consists of five lines with only the central and outer sidebands dependent on the phase. For a squeezing bandwidth much smaller than the Rabi frequency the number of lines in the spectrum and their phase properties depend on the frequency at which the squeezing and cavity modes are centered. When the squeezing and cavity modes are centered on the inner Rabi sidebands, the spectrum exhibits five lines that are completely independent of the squeezing phase with only the inner Rabi sidebands dependent on the squeezing correlations. Matching the squeezing and cavity modes to the outer Rabi sidebands leads to the disappearance of the inner Rabi sidebands and a strong phase dependence of the central line and the outer Rabi sidebands. We find that in this case the system behaves as an individual two-level system that reveals exactly the noise distribution in the input squeezed vacuum.

Physical Review A•Nov 1, 1997•8 citations
The resonance fluorescence of a two-level atom driven by a coherent laser field and damped by a finite bandwidth squeezed vacuum is analysed. We extend the Yeoman and Barnett technique to a non-zero detuning of the driving field from the atomic resonance and discuss the role of squeezing bandwidth and the detuning in the level shifts, widths and intensities of the spectral lines. The approach is valid for arbitrary values of the Rabi frequency and detuning but for the squeezing bandwidths larger than the natural line-width in order to satisfy the Markoff approximation. The narrowing of the spectral lines is interpreted in terms of the quadrature-noise spectrum. We find that, depending on the Rabi frequency, detuning and the squeezing phase, different factors contribute to the line narrowing. For a strong resonant driving field there is no squeezing in the emitted field and the fluorescence spectrum exactly reveals the noise spectrum. In this case the narrowing of the spectral lines arises from the noise reduction in the input squeezed vacuum. For a weak or detuned driving field the fluorescence exhibits a large squeezing and, as a consequence, the spectral lines have narrowed linewidths. Moreover, the fluorescence spectrum can be asymmetric about the central frequency despite the symmetrical distribution of the noise. The asymmetry arises from the absorption of photons by the squeezed vacuum which reduces the spontaneous emission. For an appropriate choice of the detuning some of the spectral lines can vanish despite that there is no population trapping. Again this process can be interpreted as arising from the absorption of photons by the squeezed vacuum. When the absorption is large it may compensate the spontaneous emission resulting in the vanishing of the fluorescence lines.
The fluorescence spectrum of a strongly driven two-level atom located inside an optical cavity damped by a narrow-bandwidth squeezed vacuum is studied. We use a dressed atom model approach, first applied to squeezed vacuum problems by Yeoman and Barnett, to derive the master equation of the system and discuss the role of the cavity and the squeezed vacuum in the narrowing of the spectral lines and the population trapping effect. We find that in the presence of a single-mode cavity the effect of squeezing on the fluorescence spectrum is more evident in the linewidths of the Rabi sidebands rather than in the linewidth of the central component. Even in the absence of squeezing, the cavity can reduce the linewidth of the central component almost to zero, whereas the Rabi sidebands can be narrowed only to some finite value. In the presence of a two-mode cavity and a two-mode squeezed vacuum the signature of squeezing is evident in the linewidths of all spectral lines. We also establish that the narrowing of the spectral lines is very sensitive to the detuning of the driving field from the atomic resonance. Moreover, we find that the population trapping effect, predicted for the broadband squeezed vacuum case, may appear in a narrow-bandwidth case only if the input squeezed modes are perfectly matched to the cavity modes and if there is non-zero squeezing at the Rabi sidebands.
The master equation for a two-level atom interacting with a strong coherent field and damped into a reservoir formed by a finite bandwidth squeezed vacuum is derived. The master equation extends the Yeoman and Barnett approach to a non-zero detuning of the driving field from the atomic resonance and allows to discuss the role of squeezing bandwidth and the detuning in the level shifts, widths and intensities of spectral lines. The approach is valid for arbitrary values of the Rabi frequency and detuning but for the squeezing bandwidths larger than the natural linewidth in order to satisfy the Markov approximation.
We present an analytical technique for investigating the behaviour of a coherently driven atom damped by a squeezed vacuum with finite squeezing bandwidth. A master equation and analytic expressions for the fluorescent spectrum are derived for the simple case of a two-level atom exactly resonant with the frequencies of both the squeezed field and the driving field. Suitable choices of driving strength, phase and squeezing source lead to either sub-natural lincwidths of the Rabi sidebands or a sub-natural linewidth of the central spectral peak or indeed sub-natural linewidths of all three spectral peaks when squeezing bandwidths are taken into account. We also establish the remarkable result that in the strong driving regime, the width of the central peak of the fluorescent spectrum depends solely on the squeezing found at the Rabi sideband frequencies.
The authors present analytical and numerical results for resonance fluorescence produced by a two-level atom damped by a broad-band squeezed vacuum. Previous theoretical analyses of this model have assumed that the laser frequency and the carrier frequency of the squeezed vacuum are equal. The authors introduce a non-zero detuning between the laser frequency and the carrier frequency while maintaining resonance between the laser frequency and atomic resonance. In the absence of the driving field there is a squeezing threshold: above threshold the decay rate of the atomic polarization can be reduced, and below threshold a squeezing-induced two peak spectrum and frequency shift, which is analogous to the Bloch-Siegert shift, are predicted. In the presence of the driving field, the spectrum is asymmetric for Rabi frequencies smaller or comparable to the detuning of the squeezed vacuum. A symmetric spectrum is obtained for large Rabi frequencies. An interpretation is predicted by means of a dressed-state analysis. The authors find that for not too large Rabi frequencies a remarkably large population inversion can be induced in the dressed states, even at exact resonance of the driving field, provided that the laser frequency and carrier frequency are detuned. Moreover, for detection times larger than the inverse detuning, the spectrum is insensitive to the phase between the driving field and the squeezed vacuum, in marked contrast to the case of no detuning.
The resonance fluorescence system of a coherently driven two-level atom in the presence of a broadband squeezed vacuum field whose central frequency is not in resonance with either the driving field frequency or the atomic transition frequency is analyzed. Solutions of the Bloch equations of the system are presented in terms of continued fractions for arbitrary strength of the coherent driving field. Numerical results are presented for the first-harmonic quadrature components of the absorption spectrum and the fluorescent intensity. The effects of the squeezed vacuum field detuning on the absorption spectrum result in hole burning or a dip structure in the weak-field case and two absorption–amplification peaks in the strong-field case. Results are sensitive to the relative phase of the squeezed vacuum.
We examine subnatural phase-dependent linewidths in the fluorescence spectrum of a three-level atom damped by a narrow-bandwidth squeezed vacuum in a cavity. Using the dressed-atom model approach of a strongly driven three-level cascade system, we derive the master equation of the system from which we obtain simple analytical expressions for the fluorescence spectrum. We show that the phase effects depend on the bandwidths of the squeezed vacuum and the cavity relative to the Rabi frequency of the driving fields. When the squeezing bandwidth is much larger than the Rabi frequency, the spectrum consists of five lines with only the central and outer sidebands dependent on the phase. For a squeezing bandwidth much smaller than the Rabi frequency the number of lines in the spectrum and their phase properties depend on the frequency at which the squeezing and cavity modes are centered. When the squeezing and cavity modes are centered on the inner Rabi sidebands, the spectrum exhibits five lines that are completely independent of the squeezing phase with only the inner Rabi sidebands dependent on the squeezing correlations. Matching the squeezing and cavity modes to the outer Rabi sidebands leads to the disappearance of the inner Rabi sidebands and a strong phase dependence of the central line and the outer Rabi sidebands. We find that in this case the system behaves as an individual two-level system that reveals exactly the noise distribution in the input squeezed vacuum.