Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Nuclear Science

Electron Interference via a 4096-Pixel MAPS Detector Designed for High-Energy Physics Experiments

G. Balbi, Stefano Frabboni, Alessandro Gabrielli, G. C. Gazzadi, Filippo Maria Giorgi, Gioṙgio Matteucci, Nicola Semprini-Cesari, M. Villa, Antonio Zoccoli

Published Sep 20, 2012• 2 citations
Publisher

Abstract

A conventional transmission electron microscope is used as a versatile optical bench in a setup where a pixel recording system, sensitive to single electrons, replaces the final viewing screen. Our detector is based on a custom CMOS chip of 4096 monolithic active pixels designed for applications in vertex detectors of future collider experiments. The chip is equipped with a fast read-out chain able to manage up to 106frames per second. This capability permitted to collect high statistics samples of single electron events within a time interval where the stable operations and the coherence conditions of the microscope were guaranteed. The microscope was configured with an accelerating potential of 60 kV, hence leading to 60 keV electrons. The large fraction of empty events made possible to obtain measurements of the time distribution of electron arrivals and this is what really characterizes this work. In fact, for the first time, conventional interference patterns have been split into single-electron frames according to the time of arrival. In particular, the 4096-pixel sensor has been used to collect diffraction patterns of a single wire, a carbon grating and eventually to reproduce the Young-Feynman two-slit experiment with single electrons instead of light. The experiment has been carried out by inserting two nanometric slits-two 100 × 1500 nm slits, 500 nm spaced apart-in the microscope that provided the electron beam source and the electro-optical lenses for projecting and focusing the pattern on the sensor. The fast readout of the sensor allowed us to record single-electron frames, spaced by several empty frames, and this is an improvement over past single-electron interference works. In this way the time distribution of the single electron arrivals has been measured with a timing resolution of 160 μs. This research might also open new detector investigation and development and characterization of pixel sensors.

DOI
10.1109/tns.2012.2214400

Related papers

Single Electron Interference and Diffraction Experiments with a High Energy Physics Detector

G. L. Alberghi, Roberto Donà, Alessandro Gabrielli +7 more

The Young-Feynman two-slit experiment for single electrons was carried out by inserting two nanometric slits and a fast recording system, capable of detecting the electron arrival-time, in a conventional transmission electron microscope. The sensor, designed for experiments at future high energy colliders, is based on a custom 4096 Monolithic Active Pixels CMOS chip, is equipped with a fast readout chain and can manage up to 10^6 frames per second, allowing the collection of high statistic samples of single electron events within a time interval compatible with the stability of the experimental setup and the coherence conditions of the illumination. For the first time in a single electron two-slit experiment, the time distribution of electron arrivals was obtained.

International Conference on Large Scale Applications and Radiation Hardness of Semiconductor Detectors (RD)•Mar 25, 2015•1 citation

Application of a HEPE-oriented 4096-MAPS to time analysis of single electron distribution in a two-slits interference experiment

A Gabrielli, Filippo Maria Giorgi, Nicola Semprini-Cesari +6 more

The Young-Feynman two-slit experiment for single electrons has been carried out by inserting in a conventional transmission electron microscope two nanometric slits and a fast recording system able to measure the electron arrival-time. The detector, designed for experiments in future colliders, is based on a custom CMOS chip of 4096 monolithic active pixels equipped with a fast readout chain able to manage up to 10 6 frames per second. In this way, high statistic samples of single electron events can be collected within a time interval short enough to guarantee the stability of the system and coherence conditions of the illumination. For the first time in a single electron two-slit experiment, the time distribution of electron arrivals has been measured.

Journal of Instrumentation•Dec 12, 2011•7 citations

Build-up of interference patterns with single electrons

Gioṙgio Matteucci, Michele Pezzi, Giulio Pozzi +8 more

A conventional transmission electron microscope, equipped with a fast recording system able to measure the electron arrival time and the position of single electrons, is used to show the build-up of interference patterns. Two experiments are presented. The first is the electron version of the Grimaldi and Young experiments performed with light, where single electrons strike on an opaque thin wire. Interference fringes are observed in the geometrical shadow of the wire and diffraction effects are clearly displayed at the wire edges. The second, original experiment reports the build-up of two-slit interference patterns with single electrons.

European Journal of Physics•Mar 4, 2013•30 citations

Interference experiment with asymmetric double slit by using 1.2-MV field emission transmission electron microscope

Ken Harada, Tetsuya Akashi, Kodai Niitsu +5 more

Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.

Scientific Reports•Jan 11, 2018•22 citations

The Young-Feynman two-slits experiment with single electrons: Build-up of the interference pattern and arrival-time distribution using a fast-readout pixel detector

Stefano Frabboni, Alessandro Gabrielli, Gian Carlo Gazzadi +6 more

Ultramicroscopy•Apr 1, 2012•73 citations

A 4096-pixel MAPS detector used to investigate the single-electron distribution in a Young–Feynman two-slit interference experiment

A. Gabrielli, Filippo Maria Giorgi, Nicola Semprini-Cesari +6 more

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment•Apr 26, 2012•3 citations
A conventional transmission electron microscope is used as a versatile optical bench in a setup where a pixel recording system, sensitive to single electrons, replaces the final viewing screen. Our detector is based on a custom CMOS chip of 4096 monolithic active pixels designed for applications in vertex detectors of future collider experiments. The chip is equipped with a fast read-out chain able to manage up to 106frames per second. This capability permitted to collect high statistics samples of single electron events within a time interval where the stable operations and the coherence conditions of the microscope were guaranteed. The microscope was configured with an accelerating potential of 60 kV, hence leading to 60 keV electrons. The large fraction of empty events made possible to obtain measurements of the time distribution of electron arrivals and this is what really characterizes this work. In fact, for the first time, conventional interference patterns have been split into single-electron frames according to the time of arrival. In particular, the 4096-pixel sensor has been used to collect diffraction patterns of a single wire, a carbon grating and eventually to reproduce the Young-Feynman two-slit experiment with single electrons instead of light. The experiment has been carried out by inserting two nanometric slits-two 100 × 1500 nm slits, 500 nm spaced apart-in the microscope that provided the electron beam source and the electro-optical lenses for projecting and focusing the pattern on the sensor. The fast readout of the sensor allowed us to record single-electron frames, spaced by several empty frames, and this is an improvement over past single-electron interference works. In this way the time distribution of the single electron arrivals has been measured with a timing resolution of 160 μs. This research might also open new detector investigation and development and characterization of pixel sensors.
The Young-Feynman two-slit experiment for single electrons was carried out by inserting two nanometric slits and a fast recording system, capable of detecting the electron arrival-time, in a conventional transmission electron microscope. The sensor, designed for experiments at future high energy colliders, is based on a custom 4096 Monolithic Active Pixels CMOS chip, is equipped with a fast readout chain and can manage up to 10^6 frames per second, allowing the collection of high statistic samples of single electron events within a time interval compatible with the stability of the experimental setup and the coherence conditions of the illumination. For the first time in a single electron two-slit experiment, the time distribution of electron arrivals was obtained.
The Young-Feynman two-slit experiment for single electrons has been carried out by inserting in a conventional transmission electron microscope two nanometric slits and a fast recording system able to measure the electron arrival-time. The detector, designed for experiments in future colliders, is based on a custom CMOS chip of 4096 monolithic active pixels equipped with a fast readout chain able to manage up to 10 6 frames per second. In this way, high statistic samples of single electron events can be collected within a time interval short enough to guarantee the stability of the system and coherence conditions of the illumination. For the first time in a single electron two-slit experiment, the time distribution of electron arrivals has been measured.
A conventional transmission electron microscope, equipped with a fast recording system able to measure the electron arrival time and the position of single electrons, is used to show the build-up of interference patterns. Two experiments are presented. The first is the electron version of the Grimaldi and Young experiments performed with light, where single electrons strike on an opaque thin wire. Interference fringes are observed in the geometrical shadow of the wire and diffraction effects are clearly displayed at the wire edges. The second, original experiment reports the build-up of two-slit interference patterns with single electrons.
Advanced electron microscopy technologies have made it possible to perform precise double-slit interference experiments. We used a 1.2-MV field emission electron microscope providing coherent electron waves and a direct detection camera system enabling single-electron detections at a sub-second exposure time. We developed a method to perform the interference experiment by using an asymmetric double-slit fabricated by a focused ion beam instrument and by operating the microscope under a "pre-Fraunhofer" condition, different from the Fraunhofer condition of conventional double-slit experiments. Here, pre-Fraunhofer condition means that each single-slit observation was performed under the Fraunhofer condition, while the double-slit observations were performed under the Fresnel condition. The interference experiments with each single slit and with the asymmetric double slit were carried out under two different electron dose conditions: high-dose for calculation of electron probability distribution and low-dose for each single electron distribution. Finally, we exemplified the distribution of single electrons by color-coding according to the above three types of experiments as a composite image.