Loss-Independent Measurement of Parametric Down Conversion Efficiency using Single Photon-Counting

Sébastien Tanzilli, Olivier Alibart, Pascal A. Baldi, N. Gisin, Marc de Micheli, Daniel B. Ostrowsky, Hugo Zbinden

Published Jan 1, 2002• 0 citations
Publisher

Abstract

We report on an original parametric down-conversion efficiency measurement method based on a coincidence counting technique that shows, for sufficiently low pump power, an independence against losses and calibration.
DOI
10.1364/nlo.2002.fc5

Related papers

Optical Absorption Measurements with Parametric Down-Converted Photons

Zhi Gao Zhao, Kent A. Meyer, William B. Whitten +1 more

It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.

Analytical Chemistry•Aug 26, 2008•3 citations

Measurement of the detection efficiency of single-photon counters based on avalanche photodiodes using the spontaneous parametric down-conversion method with spectrally asymmetric channels

P. P. Gostev, D.N. Agapov, Andrey V. Demin +3 more

Izmeritel`naya Tekhnika•Jan 1, 2018•3 citations

TWIN PHOTON BEAMS FOR SINGLE PHOTON GENERATION

Shigeki Takeuchi

We report a new method to generate parametric fluorescence into two small spots. Because the generated twins are concentrated to the spots, we observed a high single count rate and coincidence count rate per pump power. We also observed that the ratio of coincidence count rate to single count rate was 80%, where the loss at filters and the quantum efficiency of detectors were compensated. We also investigated the photon number distribution of the 'single photon pulses' using gated parametric down conversion with several types of detectors including our high-quantum efficiency multi-photon detectors. We found that the unity fraction of the single photon pulses is achievable using a CW laser pumped PDC, where the fraction of the two photon pulses are small enough.

Foundations of Quantum Mechanics in the Light of New Technology•Oct 1, 2002•1 citation

Study on the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion

Zhihan Jin, Binbin Yu, Junwei Chu +2 more

This study discusses the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion (SPDC) and coincidence counting. To address the coincidence loss induced by relative delays between two detection channels, this study proposes an accurate calculation analysis based on counting probability statistics derived from coincidence events. Additionally, an approximate method utilizing histograms and the photon count rate of detectors is proposed, which can effectively reduce the errors in coincidence loss corrections. Furthermore, the study discusses the dead time of single-photon detectors (SPDs) and proposes a weighted-average method applicable for correcting the influence of dead time.

Optics Express•Jun 11, 2025•2 citations

Measurement of the Efficiency of Detection by Single-Photon Counters Based on Avalanche Photodiodes by the Method of Spontaneous Parametric Down Conversion with Spectrally Asymmetric Channels

P. P. Gostev, D. P. Agapov, Andrey V. Demin +3 more

Measurement Techniques•Mar 1, 2019•5 citations

Towards an uncertainty budget in quantum-efficiency measurements with parametric fluorescence

G. Brida, Stefania Castelletto, Ivo Pietro Degiovanni +3 more

The aim of this paper is a critical investigation of some correction factors in the quantum-efficiency calibration of photodetectors, in the photon-counting regime, by means of correlated photons generated through a parametric down-conversion process inside a non-linear crystal. An analysis is given of the main correction factors found in a real experimental situation, with different techniques for performing coincidence counts.

Metrologia•Oct 1, 2000•37 citations
It has been known for some time that correlated detection of pairs of photons generated by parametric down-conversion can eliminate several sources of error that occur in single-beam measurements. In the correlated photon measurements, the down-converted photons are separated into two beams with one photon of a pair in each beam. The absolute detection efficiency of a detector in one beam can be determined from the count rate of a detector in the other beam and the coincidence rate for the two detectors. These ideas can be used to measure the optical absorbance of a sample placed in front of one of the detectors. Errors due to stray light and dark counts are substantially reduced and fluctuations in pump intensity largely eliminated.
We report a new method to generate parametric fluorescence into two small spots. Because the generated twins are concentrated to the spots, we observed a high single count rate and coincidence count rate per pump power. We also observed that the ratio of coincidence count rate to single count rate was 80%, where the loss at filters and the quantum efficiency of detectors were compensated. We also investigated the photon number distribution of the 'single photon pulses' using gated parametric down conversion with several types of detectors including our high-quantum efficiency multi-photon detectors. We found that the unity fraction of the single photon pulses is achievable using a CW laser pumped PDC, where the fraction of the two photon pulses are small enough.
This study discusses the correction factors in detection efficiency measurements based on spontaneous parametric down-conversion (SPDC) and coincidence counting. To address the coincidence loss induced by relative delays between two detection channels, this study proposes an accurate calculation analysis based on counting probability statistics derived from coincidence events. Additionally, an approximate method utilizing histograms and the photon count rate of detectors is proposed, which can effectively reduce the errors in coincidence loss corrections. Furthermore, the study discusses the dead time of single-photon detectors (SPDs) and proposes a weighted-average method applicable for correcting the influence of dead time.