Journal of Applied Physics

Analysis of Gaussian Light by Clipped Photocount Autocorrelation: The Effect of Finite Sampling Times and Incomplete Spatial Coherence

Dennis E. Koppel

Published Jul 1, 1971• 38 citations
Publisher

Abstract

The theoretical treatment of clipped photocount autocorrelation of Gaussian light, introduced by Jakeman and Pike, has been extended to include the effects of finite-duration sampling intervals and incomplete spatial coherence. A system of ``interval partitioning'' is used to derive theoretical expressions for 〈Nq(0)N(τ)〉 and 〈N0(0) N0(τ)〉, the single- and double-clipped photocount autocorrelation functions. Here N(t) is the number of photons detected in a sampling interval centered at t and Nq(t) is the clipped count at level q. Each original interval is systematically partitioned in space and time. Multidimensional generating functions are applied to the sets of subintervals with the object of expressing g(1) (t), the first-order field correlation function, in terms of measurable quantities. It is shown that under certain well-defined conditions, 〈Nq(0) N(τ)〉−〈Nq〉〈N〉=γq|g(1)(τ)|2 and 〈1−N0〉−2−[1−2〈N0〉+〈N0(0)N0(τ)〉]−1=φ|g(1)(τ)|2, where, for a given set of experimental parameters, γq and φ can be taken as simple multiplicative factors independent of the delay time τ. For comparative purposes, a similar analysis is performed for the unclipped correlation function 〈N(0)N(τ)〉. Finally, computer calculated values of various quantities of interest are presented for several representative cases.

DOI
10.1063/1.1660711

Related papers

Clipped correlation of integrated intensity fluctuations of gaussian light

Eric Jakeman, Christopher J. Oliver, Edward R. Pike

Experimental confirmation is presented of recent theoretical results of Jakeman on the time ever aging of photon-counting fluctuations when utilizing clipping techniques for autocorrelation. The effects of finite electronic resolving time (dead-time correction) and finite receiving apertures (spatial-coherence correction) are included.

Journal of physics. A, Proceedings of the Physical Society. General•Nov 1, 1971•33 citations

Analysis of clipped photocount autocorrelation formulae for nongaussian light

C. Bendjaballah

Three models of nongaussian stationary light are studied in which the clipped photocount autocorrelation formulae at zero photon number are not simply connected to the unclipped autocorrelation intensity function of the light field.

Journal of Physics A Mathematical Nuclear and General•Jun 1, 1973•6 citations

Theory of optical spectroscopy by digital autocorrelation of photon-counting fluctuations

Eric Jakeman

Digital autocorrelation of optical signals is discussed with particular reference to the technique of clipping, reported briefly in an earlier publication. A detailed analysis of the relationship between the autocorrelation functions of clipped and unclipped photon-counting fluctuations is given. By evaluating the generating function for the joint distribution of intensity fluctuations, corrections to the earlier results are calculated which arise if the time over which the signal is sampled is not negligible compared with any coherence time of the light. The effect of clipping in heterodyne experiments is also analysed.

Journal of physics. A, Proceedings of the Physical Society. General•Mar 1, 1970•99 citations

Moments of the Sum of Photocounts in Gaussian Light

Jacques Bures, Claude A. Delisle, Andrzej Zardecki

The statistics of the sum of photocounts in partially coherent Gaussian light is investigated. Both the case of detection at $L$ discrete points and the case of an extended surface of detection are considered. The combinatorial-analysis approach is applied to derive the moments and cumulants of the distribution. They all can be expressed in terms of the second-order correlation function. The results are generally valid independent of the ratio of the observation time to the coherence time of light. A comparison between the theoretical moments and the moments computed from experimental distributions as a function of the detector surface is carried out with the help of a pseudothermal source.

Physical Review A•Dec 1, 1972•6 citations

Scaled photocount correlation of non-Gaussian scattered light

Dennis E. Koppel, Dale W. Schaefer

The photocount autocorrelation of non-Gaussian scattered laser light is discussed as a tool for the study of both very dilute or highly correlated scattering systems. A scaled photocount correlation technique is introduced and shown to produce a function directly proportional to the correlation function of the integrated scattered intensity, independent of the field statistics. This technique overcomes the serious problems of interpretation that can arise when the commonly used clipped correlation technique is applied to non-Gaussian fields. The scaled correlation technique is demonstrated experimentally with a simple scattering system, a small number of particles under uniform translational motion.

Applied Physics Letters•Jan 1, 1973•14 citations

Comment on the letter by Jakeman et al. 'Correlation of scaled photon-counting fluctuations'

P. Tartaglia, Theodore A. Postol, S. H. Chen

Jakeman et al. (see Abstr. A73542 of 1972) have presented a method for measuring the full photocount correlation function which might be called single channel scaling (SCS). The advantage of SCS is that it can be used in conjunction with a clipped correlator to measure directly the full photocount correlation rather than the clipped correlation function. The authors point out an equally simple way of performing the same measurement and finite sum by uniformly and sequentially clipping (USC) incoming photocounts. With this method one simply clips sequentially from some maximum clipping level k=l during each of l+1 sampling periods, then starts over again at k=l. In this way the uniformity of the sampling is automatically ensured and can therefore be used as a technique to test experimentally the clipping uniformity of SCS. They performed an extensive set of measurements using both SCS and USC over a wide range of scaling and sequential clipping levels and found both methods lead to exactly equivalent results.

Journal of Physics A Mathematical Nuclear and General•Apr 1, 1973•8 citations
The theoretical treatment of clipped photocount autocorrelation of Gaussian light, introduced by Jakeman and Pike, has been extended to include the effects of finite-duration sampling intervals and incomplete spatial coherence. A system of ``interval partitioning'' is used to derive theoretical expressions for 〈Nq(0)N(τ)〉 and 〈N0(0) N0(τ)〉, the single- and double-clipped photocount autocorrelation functions. Here N(t) is the number of photons detected in a sampling interval centered at t and Nq(t) is the clipped count at level q. Each original interval is systematically partitioned in space and time. Multidimensional generating functions are applied to the sets of subintervals with the object of expressing g(1) (t), the first-order field correlation function, in terms of measurable quantities. It is shown that under certain well-defined conditions, 〈Nq(0) N(τ)〉−〈Nq〉〈N〉=γq|g(1)(τ)|2 and 〈1−N0〉−2−[1−2〈N0〉+〈N0(0)N0(τ)〉]−1=φ|g(1)(τ)|2, where, for a given set of experimental parameters, γq and φ can be taken as simple multiplicative factors independent of the delay time τ. For comparative purposes, a similar analysis is performed for the unclipped correlation function 〈N(0)N(τ)〉. Finally, computer calculated values of various quantities of interest are presented for several representative cases.
Digital autocorrelation of optical signals is discussed with particular reference to the technique of clipping, reported briefly in an earlier publication. A detailed analysis of the relationship between the autocorrelation functions of clipped and unclipped photon-counting fluctuations is given. By evaluating the generating function for the joint distribution of intensity fluctuations, corrections to the earlier results are calculated which arise if the time over which the signal is sampled is not negligible compared with any coherence time of the light. The effect of clipping in heterodyne experiments is also analysed.
The statistics of the sum of photocounts in partially coherent Gaussian light is investigated. Both the case of detection at LLL discrete points and the case of an extended surface of detection are considered. The combinatorial-analysis approach is applied to derive the moments and cumulants of the distribution. They all can be expressed in terms of the second-order correlation function. The results are generally valid independent of the ratio of the observation time to the coherence time of light. A comparison between the theoretical moments and the moments computed from experimental distributions as a function of the detector surface is carried out with the help of a pseudothermal source.
The photocount autocorrelation of non-Gaussian scattered laser light is discussed as a tool for the study of both very dilute or highly correlated scattering systems. A scaled photocount correlation technique is introduced and shown to produce a function directly proportional to the correlation function of the integrated scattered intensity, independent of the field statistics. This technique overcomes the serious problems of interpretation that can arise when the commonly used clipped correlation technique is applied to non-Gaussian fields. The scaled correlation technique is demonstrated experimentally with a simple scattering system, a small number of particles under uniform translational motion.
Jakeman et al. (see Abstr. A73542 of 1972) have presented a method for measuring the full photocount correlation function which might be called single channel scaling (SCS). The advantage of SCS is that it can be used in conjunction with a clipped correlator to measure directly the full photocount correlation rather than the clipped correlation function. The authors point out an equally simple way of performing the same measurement and finite sum by uniformly and sequentially clipping (USC) incoming photocounts. With this method one simply clips sequentially from some maximum clipping level k=l during each of l+1 sampling periods, then starts over again at k=l. In this way the uniformity of the sampling is automatically ensured and can therefore be used as a technique to test experimentally the clipping uniformity of SCS. They performed an extensive set of measurements using both SCS and USC over a wide range of scaling and sequential clipping levels and found both methods lead to exactly equivalent results.