Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of physics. A, Proceedings of the Physical Society. General

Theory of optical spectroscopy by digital autocorrelation of photon-counting fluctuations

Eric Jakeman

Published Mar 1, 1970• 99 citations
Publisher

Abstract

Digital autocorrelation of optical signals is discussed with particular reference to the technique of clipping, reported briefly in an earlier publication. A detailed analysis of the relationship between the autocorrelation functions of clipped and unclipped photon-counting fluctuations is given. By evaluating the generating function for the joint distribution of intensity fluctuations, corrections to the earlier results are calculated which arise if the time over which the signal is sampled is not negligible compared with any coherence time of the light. The effect of clipping in heterodyne experiments is also analysed.

DOI
10.1088/0305-4470/3/2/012

Related papers

Clipped correlation of integrated intensity fluctuations of gaussian light

Eric Jakeman, Christopher J. Oliver, Edward R. Pike

Experimental confirmation is presented of recent theoretical results of Jakeman on the time ever aging of photon-counting fluctuations when utilizing clipping techniques for autocorrelation. The effects of finite electronic resolving time (dead-time correction) and finite receiving apertures (spatial-coherence correction) are included.

Journal of physics. A, Proceedings of the Physical Society. General•Nov 1, 1971•33 citations

Statistical accuracy in the digital autocorrelation of photon counting fluctuations

Eric Jakeman, Edward R. Pike, S. Swain

Optical measurements by intensity fluctuation spectroscopy are subject to errors arising from the statistical nature of light and of the photo-detection process. The authors report the results of a calculation of the expected errors, due to these causes, in linewidth measurements by digital autocorrelation of photon counting fluctuations.

Journal of physics. A, Proceedings of the Physical Society. General•Nov 1, 1970•40 citations

Analysis of Gaussian Light by Clipped Photocount Autocorrelation: The Effect of Finite Sampling Times and Incomplete Spatial Coherence

Dennis E. Koppel

The theoretical treatment of clipped photocount autocorrelation of Gaussian light, introduced by Jakeman and Pike, has been extended to include the effects of finite-duration sampling intervals and incomplete spatial coherence. A system of ``interval partitioning'' is used to derive theoretical expressions for 〈Nq(0)N(τ)〉 and 〈N0(0) N0(τ)〉, the single- and double-clipped photocount autocorrelation functions. Here N(t) is the number of photons detected in a sampling interval centered at t and Nq(t) is the clipped count at level q. Each original interval is systematically partitioned in space and time. Multidimensional generating functions are applied to the sets of subintervals with the object of expressing g(1) (t), the first-order field correlation function, in terms of measurable quantities. It is shown that under certain well-defined conditions, 〈Nq(0) N(τ)〉−〈Nq〉〈N〉=γq|g(1)(τ)|2 and 〈1−N0〉−2−[1−2〈N0〉+〈N0(0)N0(τ)〉]−1=φ|g(1)(τ)|2, where, for a given set of experimental parameters, γq and φ can be taken as simple multiplicative factors independent of the delay time τ. For comparative purposes, a similar analysis is performed for the unclipped correlation function 〈N(0)N(τ)〉. Finally, computer calculated values of various quantities of interest are presented for several representative cases.

Journal of Applied Physics•Jul 1, 1971•38 citations

THE ACCURACY OF DIFFUSION-CONSTANT MEASUREMENTS BY DIGITAL AUTOCORRELATION OF PHOTON-COUNTING FLUCTUATIONS

Edward R. Pike

We discuss the accuracy of a measurement of a spectral linewidth using the method of digital correlation of single-clipped photon counting fluctuations with a given light flux and a given duration of experiment. Statistical effects due to the random nature of the light field and the photoelectric process limit this accuracy, so that the longer the duration of the experiment the more accurate the result, if all other factors are equal. Theoretical and experimental results are presented which show the accuracies obtainable as functions of the sample time, detector area and clipping level.

Le Journal de Physique Colloques•Feb 1, 1972•3 citations

Statistical accuracy in the digital autocorrelation of photon counting fluctuations

Eric Jakeman, Edward R. Pike, S. Swain

The authors investigate the statistical errors which arise in digital autocorrelation of photon counting fluctuations due to the finite duration of experiments. An expression for the accuracy with which individual points of the autocorrelation function of intensities can be measured is derived analytically and evaluated for Gaussian- Lorentzian light. The appropriate weighting for a 'least-squares' fitting procedure is determined and the error in spectral linewidth, obtained by this procedure from experiment, is calculated.

Journal of physics. A, Proceedings of the Physical Society. General•Jul 1, 1971•108 citations

Analysis of clipped photocount autocorrelation formulae for nongaussian light

C. Bendjaballah

Three models of nongaussian stationary light are studied in which the clipped photocount autocorrelation formulae at zero photon number are not simply connected to the unclipped autocorrelation intensity function of the light field.

Journal of Physics A Mathematical Nuclear and General•Jun 1, 1973•6 citations
Digital autocorrelation of optical signals is discussed with particular reference to the technique of clipping, reported briefly in an earlier publication. A detailed analysis of the relationship between the autocorrelation functions of clipped and unclipped photon-counting fluctuations is given. By evaluating the generating function for the joint distribution of intensity fluctuations, corrections to the earlier results are calculated which arise if the time over which the signal is sampled is not negligible compared with any coherence time of the light. The effect of clipping in heterodyne experiments is also analysed.
The theoretical treatment of clipped photocount autocorrelation of Gaussian light, introduced by Jakeman and Pike, has been extended to include the effects of finite-duration sampling intervals and incomplete spatial coherence. A system of ``interval partitioning'' is used to derive theoretical expressions for 〈Nq(0)N(τ)〉 and 〈N0(0) N0(τ)〉, the single- and double-clipped photocount autocorrelation functions. Here N(t) is the number of photons detected in a sampling interval centered at t and Nq(t) is the clipped count at level q. Each original interval is systematically partitioned in space and time. Multidimensional generating functions are applied to the sets of subintervals with the object of expressing g(1) (t), the first-order field correlation function, in terms of measurable quantities. It is shown that under certain well-defined conditions, 〈Nq(0) N(τ)〉−〈Nq〉〈N〉=γq|g(1)(τ)|2 and 〈1−N0〉−2−[1−2〈N0〉+〈N0(0)N0(τ)〉]−1=φ|g(1)(τ)|2, where, for a given set of experimental parameters, γq and φ can be taken as simple multiplicative factors independent of the delay time τ. For comparative purposes, a similar analysis is performed for the unclipped correlation function 〈N(0)N(τ)〉. Finally, computer calculated values of various quantities of interest are presented for several representative cases.
We discuss the accuracy of a measurement of a spectral linewidth using the method of digital correlation of single-clipped photon counting fluctuations with a given light flux and a given duration of experiment. Statistical effects due to the random nature of the light field and the photoelectric process limit this accuracy, so that the longer the duration of the experiment the more accurate the result, if all other factors are equal. Theoretical and experimental results are presented which show the accuracies obtainable as functions of the sample time, detector area and clipping level.
The authors investigate the statistical errors which arise in digital autocorrelation of photon counting fluctuations due to the finite duration of experiments. An expression for the accuracy with which individual points of the autocorrelation function of intensities can be measured is derived analytically and evaluated for Gaussian- Lorentzian light. The appropriate weighting for a 'least-squares' fitting procedure is determined and the error in spectral linewidth, obtained by this procedure from experiment, is calculated.