Physical Review Letters

Radio-Frequency Single-Electron Transistor as Readout Device for Qubits: Charge Sensitivity and Backaction

A. Aassime, Göran Johansson, Goran P. Wendin, R. J. Schoelkopf, Per Delsing

Published Apr 9, 2001• 218 citations
Publisher

Abstract

We study the radio-frequency single-electron transistor (rf-SET) as a readout device for charge qubits. We measure the charge sensitivity of an rf-SET to be 6.3microe/sqrt[Hz] and evaluate the backaction of the rf-SET on a single Cooper-pair box. This allows us to compare the needed measurement time with the mixing time of the qubit imposed by the measurement. We find that the mixing time can be substantially longer than the measurement time, which would allow readout of the state of the qubit in a single shot measurement.

DOI
10.1103/physrevlett.86.3376

Related papers

Towards Single Shot Measurements of a Cooper Pair Box Qubit Using an RF Single Electron Transistor

Carlos Alberto Sánchez

I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.

•Dec 5, 2005•0 citations

Single-shot readout with the radio-frequency single-electron transistor in the presence of charge noise

Tilo M. Buehler, D. J. Reilly, R.P. Starrett +4 more

The radio-frequency single-electron transistor (rf-SET) possesses key requirements necessary for reading out a solid state quantum computer. This work explores the use of the rf-SET as a single-shot readout device in the presence of 1∕f and telegraph charge noise. For a typical spectrum of 1∕f noise we find that high fidelity, single-shot measurements are possible for signals Δq>0.01e. For the case of telegraph noise, we present a cross-correlation measurement technique that uses two rf-SETs to suppress the effect of random switching events on readout. We demonstrate this technique by monitoring the charge state of a metal double dot system on microsecond time scales. Such a scheme will be advantageous in achieving high readout fidelity in a solid-state quantum computer.

arXiv:cond-mat/0304384•Applied Physics Letters•Mar 31, 2005•39 citations

Reading Out Charge Qubits with a Radio-Frequency Single-Electron-Transistor

Kevin Bladh, David Gunnarsson, Göran Johansson +6 more

We describe fabrication and measurements of Single Electron Transistors operated in the Radio Frequency mode (RF-SET). We demonstrate very high sensitivity for RF-SETs and we evaluate the back-action from an RF-SET, when used as a read-out device for charge qubits. We conclude that single-shot read-out is possible with a signal to noise ratio greater than one, and that niobium qubits would substantially improve the signal to noise ratio. Furthermore we describe how the RF-SET could be used to read out a differential qubit in a gradiometer coupling.

Physica Scripta•Jan 1, 2002•16 citations

Superconducting Qubits: Charge read-out and backaction

Andreas Käck

For quantum computers to become reality, not only do the qubits have to be carefully engineered to be well isolated during operation time, but this also puts great strain on the measurement setup. We have looked at the backaction from a single-electron transistor (SET), operated both in the normal and in the superconducting state, on a single Cooper-pair box qubit. We have also designed a new read-out setup for a flux qubit using a Cooper-pair transistor that would allow read-out at the flux degeneracy point. In the first case we calculate the mixing time and the influence on the qubit steady-state distribution. We find that the mixing time is larger than typical experimental measurement times, indicating the possibility of single shot read-out. For the steady-state distribution of the qubit, we calculate the Coulomb staircase, finding additional structure due to the noise in the SET. For the flux qubit we design a read-out scheme involving a quantum flip-flop process, where the measurement outcome results in the presence or absence of an incoherent tunneling process. We estimate read-out and mixing times and find that single shot read-out should be achievable.

•Jan 1, 2004•0 citations

Radio-frequency operation of a double-island single-electron transistor

R. Brenner, Tilo M. Buehler, D. J. Reilly

We present results on a double-island single-electron transistor (DISET) operated at radio frequency (rf) for the fast and highly sensitive detection of charge motion in the solid state. Using an intuitive definition for the charge sensitivity, we compare a DISET to a conventional single-electron transistor (SET). We find that a DISET can be more sensitive than a SET for identical, minimum device resistances in the Coulomb blockade regime. This is of particular importance for rf operation, where ideal impedance matching to 50-Ω transmission lines is only possible for a limited range of device resistances. We report a charge sensitivity of 5.6×10−6e∕Hz for a rf-DISET, together with a demonstration of the single-shot detection of small (⩽0.1e) charge signals on microsecond time scales.

arXiv:cond-mat/0409046•Journal of Applied Physics•Dec 30, 2004•7 citations

Full Frequency Back-Action Spectrum of a Single-Electron Transistor during Qubit Readout

Göran Johansson, Andreas Käck, Goran P. Wendin

We calculate the spectral density of voltage fluctuations in a single-electron transistor (SET), biased to operate in a transport mode where tunneling events are correlated due to Coulomb interaction. The whole spectrum from low frequency shot noise to quantum noise at frequencies comparable to the SET charging energy (EC/h) is considered. We discuss the back-action during readout of a charge qubit and conclude that single-shot readout is possible using the radio-frequency SET.

arXiv:cond-mat/0106650•Physical Review Letters•Jan 10, 2002•60 citations
We study the radio-frequency single-electron transistor (rf-SET) as a readout device for charge qubits. We measure the charge sensitivity of an rf-SET to be 6.3microe/sqrt[Hz] and evaluate the backaction of the rf-SET on a single Cooper-pair box. This allows us to compare the needed measurement time with the mixing time of the qubit imposed by the measurement. We find that the mixing time can be substantially longer than the measurement time, which would allow readout of the state of the qubit in a single shot measurement.
I report an investigation into using an rf Single Electron Transistor (rf-SET) to implement single shot readout of the quantum state of a Cooper pair box. I fabricated Al/AlOx/Al SETs and Cooper pair boxes using e-beam lithography and double-angle evaporation. The devices had typical charging energies of about 1 K and were measured at 30 mK in a dilution refrigerator. I built rf-SETs with an LC resonant circuit integrated on the chip and operating frequencies of 650 MHz and 1.5 GHz. The rf-SETs had a typical bandwidth of 30 MHz and the best achieved charge sensitivity was 8X10-6 erms/(Hz)1/2 at 1.5 GHz. The rf-SETs were used to measure the Coulomb staircase on the Cooper pair box. Measurements of the staircase show features due to quasiparticle poisoning that are dependent on temperature and SET bias. The data was compared to a theory I developed to extend existing theories of quasiparticle poisoning. My model is based on the calculation of tunneling rates to explain observations of parity effects in the Cooper pair box over a wide temperature range. Quantum state control of the Cooper pair box was demonstrated by using fast voltage pulses applied to the gate. Temporal oscillations of charge states and spectroscopy measurements reveal a dephasing time T2=200 ps at 30 mK, for a drive frequency of 30 GHz. The energy relaxation time T1=140 ns was determined from time domain measurements of the decay of the Cooper pair box charge. The fidelity of single shot measurements and the feasibility of this quantum readout scheme based on the results are discussed.
The radio-frequency single-electron transistor (rf-SET) possesses key requirements necessary for reading out a solid state quantum computer. This work explores the use of the rf-SET as a single-shot readout device in the presence of 1∕f and telegraph charge noise. For a typical spectrum of 1∕f noise we find that high fidelity, single-shot measurements are possible for signals Δq>0.01e. For the case of telegraph noise, we present a cross-correlation measurement technique that uses two rf-SETs to suppress the effect of random switching events on readout. We demonstrate this technique by monitoring the charge state of a metal double dot system on microsecond time scales. Such a scheme will be advantageous in achieving high readout fidelity in a solid-state quantum computer.
We describe fabrication and measurements of Single Electron Transistors operated in the Radio Frequency mode (RF-SET). We demonstrate very high sensitivity for RF-SETs and we evaluate the back-action from an RF-SET, when used as a read-out device for charge qubits. We conclude that single-shot read-out is possible with a signal to noise ratio greater than one, and that niobium qubits would substantially improve the signal to noise ratio. Furthermore we describe how the RF-SET could be used to read out a differential qubit in a gradiometer coupling.
For quantum computers to become reality, not only do the qubits have to be carefully engineered to be well isolated during operation time, but this also puts great strain on the measurement setup. We have looked at the backaction from a single-electron transistor (SET), operated both in the normal and in the superconducting state, on a single Cooper-pair box qubit. We have also designed a new read-out setup for a flux qubit using a Cooper-pair transistor that would allow read-out at the flux degeneracy point. In the first case we calculate the mixing time and the influence on the qubit steady-state distribution. We find that the mixing time is larger than typical experimental measurement times, indicating the possibility of single shot read-out. For the steady-state distribution of the qubit, we calculate the Coulomb staircase, finding additional structure due to the noise in the SET. For the flux qubit we design a read-out scheme involving a quantum flip-flop process, where the measurement outcome results in the presence or absence of an incoherent tunneling process. We estimate read-out and mixing times and find that single shot read-out should be achievable.
We present results on a double-island single-electron transistor (DISET) operated at radio frequency (rf) for the fast and highly sensitive detection of charge motion in the solid state. Using an intuitive definition for the charge sensitivity, we compare a DISET to a conventional single-electron transistor (SET). We find that a DISET can be more sensitive than a SET for identical, minimum device resistances in the Coulomb blockade regime. This is of particular importance for rf operation, where ideal impedance matching to 50-Ω transmission lines is only possible for a limited range of device resistances. We report a charge sensitivity of 5.6×10−6e∕Hz for a rf-DISET, together with a demonstration of the single-shot detection of small (⩽0.1e) charge signals on microsecond time scales.