Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics A

A Rb-magnetometer for a wide range and high sensitivity

Werner D. Farr, Ernst Wilhelm Otten

Published May 1, 1974• 26 citations
Publisher
DOI
10.1007/bf00885841

Related papers

A High Sensitive Atomic Co-magnetometer for Rotation Rate Measurement Based on K-Rb-21Ne

Yao Chen, Sheng Zou, Wei Quan +3 more

Bulletin of the American Physical Society•May 27, 2016•0 citations

Atomic free-spin-precession magnetometer for biomagnetic measurements in Earth-range magnetic fields

Philipp Neufeld, Janine Riedrich‐Möller, Tino Fuchs +1 more

We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.

APS Open Science•Jun 8, 2026•0 citations

Chip-scale magnetometers

Michael V. Romalis

Nature Photonics•Nov 1, 2007•11 citations

Spin exchange broadening of magnetic resonance lines in a high-sensitivity rotating K-Rb-21Ne co-magnetometer

Yao Chen, Wei Quan, Sheng Zou +6 more

Abstract Atomic co-magnetometers can be utilized for high-precision angular velocity sensing or fundamental physics tests. The sensitivity of a co-magnetometer determines the angle random walk of an angular velocity sensor and the detection limit for a fundamental physics test. A high-sensitivity K-Rb-21Ne co-magnetometer, which is utilized for angular velocity sensing, is presented in this paper. A new type of spin relaxation of Rb atom spins, which can broaden the zero-field magnetic resonance lines of the co-magnetometer, is discovered. Further studies show that the spin relaxation of Rb atoms is caused by a high Rb electron magnetization field. With this discovery, the total relaxation rate of Rb atoms is optimized to improve the sensitivity of the co-magnetometer. Moreover, its sensitivity is optimized by suppressing various noises. Especially, to suppress laser-related noises, the co-magnetometer is designed such that the sensitive axis of the co-magnetometer can be fixed to the direction in which the projection input of the earth’s rotation is 0. This is called a rotating co-magnetometer. A magnetic field sensitivity of 1.0 fT/Hz−1/2@5 Hz, which is equal to an angular velocity sensitivity of 2.1 × 10−8 rad s−1 Hz−1/2@5 Hz, is demonstrated using a spherical vapour cell with a diameter of 14 mm.

Scientific Reports•Nov 10, 2016•72 citations

Experimental Investigation on a Highly Sensitive Atomic Magnetometer

李曙光, 徐云飞, 王兆英 +2 more

Chinese Physics Letters•Jan 1, 2009•1 citation

High sensitivity closed-loop Rb optically pumped magnetometer for measuring nuclear magnetization

Siran Li, Danyue Ma, Kun Wang +5 more

Rb optically pumped magnetometer (OPM) based on electron paramagnetic resonance (EPR) show advantages to measure the nuclear magnetization and have succeeded in fundamental physics and rotation sensing, etc . The magnetometry sensitivity is a key performance of these Rb OPMs which should be improved. In this study, a high sensitivity Rb OPM is demonstrated theoretically and experimentally. To improve the sensitivity, acousto-optic modulation based on balanced detection is applied to suppress the probe noises. Compared with the conventional optical rotation detection for this OPM configuration, the probe noise shows a significant suppression especially in low frequencies. Eventually, a simultaneous dual-axis transverse measurement with 30 fT/Hz 1/2 sensitivity is achieved in a 200 Hz bandwidth and a 250nT linear working range. In addition, we utilize a closed-loop feedback to improve the stability and enlarge the transverse measurement range to 10µT order of magnitude while maintain the open-loop performances. A quasi-static magnetic field measurement can also be achieved in the longitudinal direction in the closed-loop mode. This OPM can serve for the nuclear magnetization measurement with a high sensitivity especially in environments with a large magnitude of the external magnetic field.

Optics Express•Nov 16, 2022•6 citations
We present an implementation of an atomic magnetometer based on free spin precession of optically pumped Rb 87 atoms. The design features a microfabricated vapor cell with an effective volume of 7.1 mm 3 containing isotopically enriched Rb 87 and nitrogen buffer gas. The magnetometer is designed to operate in the Earth-field range, exhibiting a magnetic noise floor of about 147 fT / Hz at field strengths comparable to Earth's magnetic field, i.e., around 50 μ T . This is in close agreement with the Cramér-Rao lower bound of 118 fT / Hz . The good sensitivity as well as the high dynamic range enables a wide range of applications, including magnetocardiography and geomagnetic measurements.
Abstract Atomic co-magnetometers can be utilized for high-precision angular velocity sensing or fundamental physics tests. The sensitivity of a co-magnetometer determines the angle random walk of an angular velocity sensor and the detection limit for a fundamental physics test. A high-sensitivity K-Rb-21Ne co-magnetometer, which is utilized for angular velocity sensing, is presented in this paper. A new type of spin relaxation of Rb atom spins, which can broaden the zero-field magnetic resonance lines of the co-magnetometer, is discovered. Further studies show that the spin relaxation of Rb atoms is caused by a high Rb electron magnetization field. With this discovery, the total relaxation rate of Rb atoms is optimized to improve the sensitivity of the co-magnetometer. Moreover, its sensitivity is optimized by suppressing various noises. Especially, to suppress laser-related noises, the co-magnetometer is designed such that the sensitive axis of the co-magnetometer can be fixed to the direction in which the projection input of the earth’s rotation is 0. This is called a rotating co-magnetometer. A magnetic field sensitivity of 1.0 fT/Hz−1/2@5 Hz, which is equal to an angular velocity sensitivity of 2.1 × 10−8 rad s−1 Hz−1/2@5 Hz, is demonstrated using a spherical vapour cell with a diameter of 14 mm.
Rb optically pumped magnetometer (OPM) based on electron paramagnetic resonance (EPR) show advantages to measure the nuclear magnetization and have succeeded in fundamental physics and rotation sensing, etc . The magnetometry sensitivity is a key performance of these Rb OPMs which should be improved. In this study, a high sensitivity Rb OPM is demonstrated theoretically and experimentally. To improve the sensitivity, acousto-optic modulation based on balanced detection is applied to suppress the probe noises. Compared with the conventional optical rotation detection for this OPM configuration, the probe noise shows a significant suppression especially in low frequencies. Eventually, a simultaneous dual-axis transverse measurement with 30 fT/Hz 1/2 sensitivity is achieved in a 200 Hz bandwidth and a 250nT linear working range. In addition, we utilize a closed-loop feedback to improve the stability and enlarge the transverse measurement range to 10µT order of magnitude while maintain the open-loop performances. A quasi-static magnetic field measurement can also be achieved in the longitudinal direction in the closed-loop mode. This OPM can serve for the nuclear magnetization measurement with a high sensitivity especially in environments with a large magnitude of the external magnetic field.