Advances in Optical Sciences Congress

High brightness, tunable diode laser based continuous-wave biphoton source for two photon absorption at 976 nm

Andreas Jechow, Axel Heuer, Ralf Menzel

Published Jan 1, 2009• 0 citations
Publisher

Abstract

A compact all solid state biphoton source based on a frequency doubled diode laser and a PPLN waveguide crystal is presented. More than 1011 photon pairs per second in one transversal mode could be generated.
DOI
10.1364/nlo.2009.jtub21

Related papers

High brightness, tunable biphoton source at 976 nm for quantum spectroscopy

Andreas Jechow, Axel Heuer, Ralf Menzel

A compact all solid state continuous-wave biphoton source, tunable around 488 nm, for quantum spectroscopic applications based on a frequency doubled diode laser system is presented. Copolarized photon pairs in the fundamental transversal mode could be generated at 976 nm by spontaneous parametric down conversion inside a type-0 quasi phase matched periodically poled lithium niobate waveguide crystal with an efficiency of 8-10(-6). A high flux rate greater than 10(7) photon pairs per second has been achieved at pump powers in the muW range resulting in more than 7-10(9) photon pairs/s-mW. Further a detailed investigation of the spectral behavior and the flux rate as a function of the detuning from the degenerated case is presented.

Optics Express•Aug 15, 2008•22 citations

Tunable diode laser based biphoton source for quantum spectroscopy

Andreas Jechow, Axel Heuer, Ralf Menzel

Photon pairs generated by spontaneous parametric down-conversion (SPDC) are essential for a number of quantum-optics experiments. By utilizing periodically poled (PP) waveguide structures high flux rates of biphotons in one transversal mode can be obtained. The biphoton source presented here is explicitly designed for quantum spectroscopic application and is based on a frequency doubled broad area external cavity diode laser (BA-ECDL) that pumps SPDC inside a PPLN waveguide crystal. A time correlated single photon counting device has been used for the correlation measurements.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2009•0 citations

Compact all-solid-state source of polarization-entangled photon pairs

Jürgen Volz, Christian Kurtsiefer, Harald Weinfurter

A compact source of polarization-entangled photon pairs at a wavelength of 856 nm is realized using a frequency-doubled laser diode as the pump source for cavity-enhanced type-II spontaneous parametric down-conversion. Our setup generates photon pairs with entanglement visibility of ⩾95% and with count rates comparable to those of standard experiments based on large-frame ion lasers.

Applied Physics Letters•Aug 6, 2001•26 citations

Photonic crystal fiber source of correlated photon pairs

John G. Rarity, Jérémie Fulconis, J. L. Duligall +2 more

We generate correlated photon pairs at 839 nm and 1392 nm from a single-mode photonic crystal fiber pumped in the normal dispersion regime. This compact, bright, tunable, single-mode source of pair-photons will have wide application in quantum communications.

Optics Express•Jan 1, 2005•273 citations

Correlated-photon-pair emission from a cw-pumped Fabry-Perot microcavity

Thorsten F. Langerfeld, Hendrik M. Meyer, Michael Köhl

Kerr nonlinearity in an optical coating is explored to generate photon pairs within a high-finesse Fabry-Perot resonator. The scheme, based on a continuous-wave diode laser, provides a robust and frequency-tunable quantum source.

arXiv:1711.04424•Physical Review A•Feb 13, 2018•8 citations

Continuous laser source for cooling Rubidium atoms using second harmonic generation from a PPLN crystal

Alexandre Bresson, Xavier Orlik, Aurélien Manchon +1 more

We have realized a compact, 0.2 W continuous sub-MHz laser source at 780 nm from second harmonic generation inside a periodically poled LiNbO/sub 3/ crystal. The fiber system fulfill requirements for cooling and trapping Rubidium atoms.

Conference on Lasers and Electro-Optics•May 16, 2004•0 citations
A compact all solid state continuous-wave biphoton source, tunable around 488 nm, for quantum spectroscopic applications based on a frequency doubled diode laser system is presented. Copolarized photon pairs in the fundamental transversal mode could be generated at 976 nm by spontaneous parametric down conversion inside a type-0 quasi phase matched periodically poled lithium niobate waveguide crystal with an efficiency of 8-10(-6). A high flux rate greater than 10(7) photon pairs per second has been achieved at pump powers in the muW range resulting in more than 7-10(9) photon pairs/s-mW. Further a detailed investigation of the spectral behavior and the flux rate as a function of the detuning from the degenerated case is presented.
Photon pairs generated by spontaneous parametric down-conversion (SPDC) are essential for a number of quantum-optics experiments. By utilizing periodically poled (PP) waveguide structures high flux rates of biphotons in one transversal mode can be obtained. The biphoton source presented here is explicitly designed for quantum spectroscopic application and is based on a frequency doubled broad area external cavity diode laser (BA-ECDL) that pumps SPDC inside a PPLN waveguide crystal. A time correlated single photon counting device has been used for the correlation measurements.