Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Hot-electron superconductive mixers for THz frequencies

William R. McGrath, Boris S. Karasik, Anders J. Skalare, Rolf A. Wyss, B. Bumble, Henry George LeDuc

Published Apr 29, 1999• 9 citations
Publisher

Abstract

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device employs diffusion as a cooling mechanism for hot electrons. The double sideband receiver noise temperature was measured to be approximately equals 2750 K at 2.5 K at 2.5 THz; and mixer IF bandwidths as high as 9 GHz are achieved for 0.1 micrometers long devices. The local oscillator power dissipated in the HEB microbridge was in the range 20- 100 nW. Further reductions in LO power and mixer noise can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. A distributed-temperature model has been developed to properly describe the operation of the diffusion-cooled HEB mixer. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies.

DOI
10.1117/12.347111

Related papers

Low-noise and wideband hot-electron superconductive mixer for terahertz frequencies

Boris S. Karasik, Anders J. Skalare, William R. McGrath +7 more

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device is a 0.15 - 0.3 micrometer microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be less than or equal to 3000 K at 2.5 THz and the mixer IF bandwidth is expected to be at least 10 GHz for a 0.1 micrometer long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20 - 100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa2Cu3O7-(delta ) (YBCO) HEB are discussed. The expected LO power of 1 - 10 (mu) W and SSB noise temperature of approximately equals 2000 K may make this mixer attractive for various remote sensing applications.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 13, 1998•1 citation

Low-noise and wideband hot-electron superconductive mixers for THz frequencies

Boris S. Karasik, Anders J. Skalare, Rolf A. Wyss +5 more

Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range 1.1-2.5 THz. The mixer device is a 0.15-03 /spl mu/m microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be /spl les/3000 K at 2.5 THz and the mixer IF bandwidth is /spl ap/9-10 GHz for a 0.1 /spl mu/m long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20-100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated The HEB mixer Is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// (YBCO) HEB are also discussed. The expected LO power of 1-10 /spl mu/W and SSB noise temperature of /spl ap/2000 K may make this mixer attractive for various remote sensing applications.

IEEE International Conference on Terahertz Electronics (THz)•Nov 27, 2002•5 citations

Noise and Bandwidth Measurements of Diffusion-Cooled Nb Hot-Electron Bolometer Mixers at Frequencies Above the Superconductive Energy Gap

Rolf A. Wyss, Boris S. Karasik, William R. McGrath +2 more

Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.

Softwaretechnik-Trends•Jan 1, 1999•20 citations

Superconductive hot-electron mixers for terahertz heterodyne receiver applications

William R. McGrath, Anders J. Skalare, Boris S. Karasik +6 more

We report on the development of quasioptical Nb hot-electron bolometer mixers for heterodyne receivers operating at 1 THz 3 THz. The devices have submicron in-plane sizes, thus exploiting diffusion as the electron cooling mechanism. Quasioptical mixer circuits have been developed with planar double-dipole or twin-slot antennas. The measured (DSB) receiver noise temperatures are 1670 K at 1.1 THz, with an estimated mixer noise temperature of approximately equals 1060 K, and 2750 K at 2.5 THz, with an estimated mixer noise temperature of approximately equals 900 K. The IF bandwidth is found to scale as the length-squared, and bandwidths as high as 8 GHz have been measured. These results demonstrate the low-noise, broadband operation of the diffusion-cooled bolometer mixer over a wide range of far-infrared wavelengths.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 31, 1998•4 citations

Aluminum hot-electron bolometer mixers at submillimeter wavelengths

Anders J. Skalare, William R. McGrath, P. M. Echternach +4 more

Diffusion-cooled aluminum hot-electron bolometer (HEB) mixers are of interest for low-noise high resolution THz-frequency spectroscopy within astrophysics. Al HEB mixers offer operation with an order of magnitude less local oscillator power, higher intermediate frequency bandwidth and potentially lower noise than competing devices made from other materials. We report on mixer experiments at 618 GHz with devices fabricated from films with sheet resistances in the range from about 55 /spl Omega/ down to about 9 /spl Omega/ per square. Intermediate frequency bandwidths of up to 3 GHz were measured (1 /spl mu/m long device), with absorbed local oscillator power levels of 0.5 to 6 nW and mixer conversion up to -21.5 dB. High input coupling efficiency implies that the electrons in the device are able to thermalize before escaping from the device. It was found that the long coherence length complicates mixer operations due to the proximity of the contact pads. Also, saturation at the IF frequency may be a concern for this type of device, and warrants further studies.

IEEE Transactions on Applied Superconductivity•Mar 1, 2001•17 citations

Development of 1.5 THz waveguide NbTiN superconducting hot electron bolometer mixers

Ling Jiang, Shoichi Shiba, Tatsuya Shiino +7 more

We present a characterization of a 1.5 THz waveguide niobium titanium nitride (NbTiN) superconducting hot electron bolometer (HEB) mixer which can be pumped by a commercial solid state tunable local oscillator (LO) source. The NbTiN HEB mixer is made from a 12 nm thick NbTiN thin film deposited on a quartz substrate at room temperature. A gold electrode is formed in situ on the NbTiN thin film without breaking vacuum to ensure good contact. The uncorrected DSB receiver noise temperature is measured to be 1700 K at 1.5 THz, whereas the mixer noise temperature is derived to be 1000 K after corrections for losses of the input optics and the intermediate frequency (IF) amplifier chain. The required LO power absorbed in the HEB mixer is evaluated to be 340 nW by using an isothermal technique. The IF gain bandwidth is supposed to be about 1.3 GHz or higher. The present results show that good performance can be obtained at 1.5 THz even with a relatively thick NbTiN film (12 nm), as in the case of 0.8 THz. In order to investigate the cooling mechanism of our HEB mixers, we have conducted performance measurements for a few HEB mixers with different microbridge sizes both at 1.5 and 0.8 THz. The noise performance of the NbTiN HEB mixers is found to depend on the length of the NbTiN microbridge. The shorter the microbridge is, the lower the receiver noise temperature is. This may imply a contribution of the diffusion cooling in addition to the phonon cooling.

Superconductor Science and Technology•Mar 19, 2010•20 citations
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device employs diffusion as a cooling mechanism for hot electrons. The double sideband receiver noise temperature was measured to be approximately equals 2750 K at 2.5 K at 2.5 THz; and mixer IF bandwidths as high as 9 GHz are achieved for 0.1 micrometers long devices. The local oscillator power dissipated in the HEB microbridge was in the range 20- 100 nW. Further reductions in LO power and mixer noise can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. A distributed-temperature model has been developed to properly describe the operation of the diffusion-cooled HEB mixer. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies.
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range from 1.1 THz to 2.5 THz. The mixer device is a 0.15 - 0.3 micrometer microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be less than or equal to 3000 K at 2.5 THz and the mixer IF bandwidth is expected to be at least 10 GHz for a 0.1 micrometer long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20 - 100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated. The HEB mixer is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa2Cu3O7-(delta ) (YBCO) HEB are discussed. The expected LO power of 1 - 10 (mu) W and SSB noise temperature of approximately equals 2000 K may make this mixer attractive for various remote sensing applications.
Superconductive hot-electron bolometer (HEB) mixers have been built and tested in the frequency range 1.1-2.5 THz. The mixer device is a 0.15-03 /spl mu/m microbridge made from a 10 nm thick Nb film. This device employs diffusion as a cooling mechanism for hot electrons. The double sideband noise temperature was measured to be /spl les/3000 K at 2.5 THz and the mixer IF bandwidth is /spl ap/9-10 GHz for a 0.1 /spl mu/m long device. The local oscillator (LO) power dissipated in the HEB microbridge was 20-100 nW. Further improvement of the mixer characteristics can be potentially achieved by using Al microbridges. The advantages and parameters of such devices are evaluated The HEB mixer Is a primary candidate for ground based, airborne and spaceborne heterodyne instruments at THz frequencies. HEB receivers are planned for use on the NASA Stratospheric Observatory for Infrared Astronomy (SOFIA) and the ESA Far Infrared and Submillimeter Space Telescope (FIRST). The prospects of a submicron-size YBa/sub 2/Cu/sub 3/O/sub 7-/spl delta// (YBCO) HEB are also discussed. The expected LO power of 1-10 /spl mu/W and SSB noise temperature of /spl ap/2000 K may make this mixer attractive for various remote sensing applications.
Diffusion-cooled Nb hot-electron bolometer (HEB) mixers have the potential to simultaneously achieve high intermediate frequency (IF) bandwidths and low mixer noise temperatures for operation at THz frequencies (above the superconductive gap energy). We have measured the IF signal bandwidth at 630 GHz of Nb devices with lengths L = 0.3, 0.2, and 0.1 micrometer in a quasioptical mixer configuration employing twin-slot antennas. The 3-dB EF bandwidth increased from 1.2 GHz for the 0.3 gm long device to 9.2 GHz for the 0.1 gm long device. These results demonstrate the expected 1/L squared dependence of the IF bandwidth at submillimeter wave frequencies for the first time, as well as the largest EF bandwidth obtained to date. For the 0.1 gm device, which had the largest bandwidth, the double sideband (DSB) noise temperature of the receiver was 320-470 K at 630 GHz with an absorbed LO power of 35 nW, estimated using the isothermal method. A version of this mixer with the antenna length scaled for operation at 2.5 THz has also been tested. A DSB receiver noise temperature of 1800 plus or minus 100 K was achieved, which is about 1,000 K lower than our previously reported results. These results demonstrate that large EF bandwidth and low-noise operation of a diffusion-cooled HEB mixer is possible at THz frequencies with the same device geometry.
We report on the development of quasioptical Nb hot-electron bolometer mixers for heterodyne receivers operating at 1 THz 3 THz. The devices have submicron in-plane sizes, thus exploiting diffusion as the electron cooling mechanism. Quasioptical mixer circuits have been developed with planar double-dipole or twin-slot antennas. The measured (DSB) receiver noise temperatures are 1670 K at 1.1 THz, with an estimated mixer noise temperature of approximately equals 1060 K, and 2750 K at 2.5 THz, with an estimated mixer noise temperature of approximately equals 900 K. The IF bandwidth is found to scale as the length-squared, and bandwidths as high as 8 GHz have been measured. These results demonstrate the low-noise, broadband operation of the diffusion-cooled bolometer mixer over a wide range of far-infrared wavelengths.
Diffusion-cooled aluminum hot-electron bolometer (HEB) mixers are of interest for low-noise high resolution THz-frequency spectroscopy within astrophysics. Al HEB mixers offer operation with an order of magnitude less local oscillator power, higher intermediate frequency bandwidth and potentially lower noise than competing devices made from other materials. We report on mixer experiments at 618 GHz with devices fabricated from films with sheet resistances in the range from about 55 /spl Omega/ down to about 9 /spl Omega/ per square. Intermediate frequency bandwidths of up to 3 GHz were measured (1 /spl mu/m long device), with absorbed local oscillator power levels of 0.5 to 6 nW and mixer conversion up to -21.5 dB. High input coupling efficiency implies that the electrons in the device are able to thermalize before escaping from the device. It was found that the long coherence length complicates mixer operations due to the proximity of the contact pads. Also, saturation at the IF frequency may be a concern for this type of device, and warrants further studies.
We present a characterization of a 1.5 THz waveguide niobium titanium nitride (NbTiN) superconducting hot electron bolometer (HEB) mixer which can be pumped by a commercial solid state tunable local oscillator (LO) source. The NbTiN HEB mixer is made from a 12 nm thick NbTiN thin film deposited on a quartz substrate at room temperature. A gold electrode is formed in situ on the NbTiN thin film without breaking vacuum to ensure good contact. The uncorrected DSB receiver noise temperature is measured to be 1700 K at 1.5 THz, whereas the mixer noise temperature is derived to be 1000 K after corrections for losses of the input optics and the intermediate frequency (IF) amplifier chain. The required LO power absorbed in the HEB mixer is evaluated to be 340 nW by using an isothermal technique. The IF gain bandwidth is supposed to be about 1.3 GHz or higher. The present results show that good performance can be obtained at 1.5 THz even with a relatively thick NbTiN film (12 nm), as in the case of 0.8 THz. In order to investigate the cooling mechanism of our HEB mixers, we have conducted performance measurements for a few HEB mixers with different microbridge sizes both at 1.5 and 0.8 THz. The noise performance of the NbTiN HEB mixers is found to depend on the length of the NbTiN microbridge. The shorter the microbridge is, the lower the receiver noise temperature is. This may imply a contribution of the diffusion cooling in addition to the phonon cooling.