AIP conference proceedings

Multiplexable kinetic inductance detectors

Ben Mazin, Peter K. Day, Jonas Stasys Zmuidzinas, Henry George LeDuc

Published Jan 1, 2002• 47 citations
Publisher

Abstract

We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors.This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution.The readout is based on the fact that the kinetic surface inductance L s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T c .An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit.By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 //m 3 .As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor.However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~ 10 3 detectors with a single HEMT amplifier. DETECTOR CONCEPTKinetic inductance detectors operate on the principle that a change in the number of quasiparticles in a superconductor will produce a change in the kinetic inductance.This occurs because the quasiparticles block Cooper pairs from occupying some of the electron states.Photons (or particles) are absorbed in the superconductor, producing quasiparticles, and the resulting change in the inductance is measured to produce the detector output.Bolometric detectors using kinetic inductance thermometers have been previously suggested [1, 2, 3, 4, 5, 6].However, such thermometers must be operated close to T c , since the variation of the kinetic inductance with temperature is most rapid near T c , and vanishes exponentially at low temperatures.Although it has been discussed previously [7], it is not widely appreciated that the the variation of the kinetic inductance with energy or quasiparticle number is actually fairly constant down to very low temperatures.The idea, then, is to use the kinetic inductance effect to read out changes in the quasiparticle population produced by the direct absorbtion of pair-breaking photons rather than changes in the temperature of the phonons in a bolometric absorber.How can one measure the change in the kinetic inductance of a superconductor?One way is to make the superconductor act as an inductive element in a resonant circuit.A change in the quasiparticle population will change the inductance of the superconductor, and therefore the resonance frequency of the circuit, which can be monitored by measuring the transmission phase of a constant-frequency microwave probe signal transmitted through (or reflected from) the resonator.This method is extremely attractive, due both to CP605, Low Temperature Detectors, edited by F. S. Porter et al.

DOI
10.1063/1.1457652

Related papers

Ultrasensitive hot-electron kinetic-inductance detectors

A. Sergeev, Boris S. Karasik, I. G. Gogidze +1 more

While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.

AIP conference proceedings•Jan 1, 2002•3 citations

Non-Equilibrium Superconductivity in Kinetic Inductance Detectors for THz Photon Sensing

D. J. Goldie, S. Withington

Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang and Scalapino.[1] At the lowest bath temperature studied Tb/Tc = 0.1 the quasiparticle distributions can be driven far from equilibrium. In addition to the low frequency probe signal we have incorporated a high frequency (~ 1 THz) source signal well-above the pair-breaking threshold of the superconductor. Calculations of source signal detection efficiency are discussed

arXiv:1401.2291•Jan 10, 2014•1 citation

Theoretical modeling of optical and x-ray photon counting kinetic inductance detectors

George A. Vardulakis, S. Withington, D. J. Goldie

We present a theoretical model of a superconducting kinetic inductance detector which promises high sensitivity and energy resolution from submillimetre to X-ray wavelengths. Cooper-pair breaking photons are absorbed in a superconductor, exciting quasiparticles which change the surface inductance. By arranging the detector in a resonant circuit we can measure the resulting phase-shift of a microwave probe signal. Software has been created to model the superconducting characteristics of the detector and its behaviour when a photon is absorbed. The model predicts the position sensitivity of the detector and calculates how quasiparticles diffuse and recombine to a thermal background level. This temporal evolution of quasiparticle dynamics gives rise to a measurable phase-shift pulse, which will allow the energy and time of a photon to be measured. Pulse shapes have been simulated for photon energies of 1-5 keV being absorbed at the sensitive ground-end of the detector.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Sep 29, 2004•2 citations

A measurement method for responsivity of microwave kinetic inductance detector by changing power of readout microwaves

Hiroki Kutsuma, M. Hattori, Ryo Koyano +5 more

Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of the cutting-edge superconducting detectors. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase responses as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285 mK. We also confirm the consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.

arXiv:1907.03403•Applied Physics Letters•Jul 15, 2019•5 citations

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

Edward J. Wollack, Kongpop U-yen, Thomas R. Stevenson +3 more

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

•Dec 1, 2013•0 citations

Far-infrared kinetic-inductance detectors

Erich N. Grossman, Donald G. McDonald, Joseph E. Sauvageau

Extremely sensitive far-infrared detectors suitable for both direct detection and heterodyne applications, based on mu m-sized thin films with thickness less than a superconducting penetration depth are possible. The penetration depth of such a film, and therefore its inductance, varies with temperature and with quasiparticle population (described by an effective temperature T*), resulting in both bolometric and nonequilibrium photoinductive responses. Incident radiation is coupled into the small-area kinetic inductor by a lithographic antenna, and the resulting inductance changes are amplified and converted to a voltage signal by an integrated microstrip DC SQUID. The device is sensitive because, unlike junction-based devices with large capacitive reactances, the kinetic inductor is naturally well matched to the antenna impedance at the far-IR frequency ( nu >2 Delta /h) and to the preamplifier (SQUID) impedance at microwave or video frequencies ( nu <<2 Delta /h). The best kinetic inductor materials are those with low electronic mean free path, large penetration depth, and high critical current density. Thus, common magnet alloys such as NbTi are the natural choice for liquid-He temperature operation. A detailed analysis predicts a (phonon-limited) NEP of 4*10/sup -17/ W/ square root Hz for a bolometer with an iridium kinetic inductor operated at 0.1 K. A heterodyne noise temperature of 2250 K (single-sideband) at 3 THz, with a 200-MHz bandwidth, is predicted for a Nb-Ti mixer operated at 4 K.

IEEE Transactions on Magnetics•Mar 1, 1991•39 citations
We are starting to investigate a novel multiplexable readout method that can be applied to a large class of superconducting pair-breaking detectors.This readout method is completely different from those currently used with STJ and TES detectors, and in principle could deliver large pixel counts, high sensitivity, and Fano-limited spectral resolution.The readout is based on the fact that the kinetic surface inductance L s of a superconductor is a function of the density of quasiparticles n, even at temperatures far below T c .An efficient way to measure changes in the kinetic inductance is to monitor the transmission phase of a resonant circuit.By working at microwave frequencies and using thin films, the kinetic inductance can be a significant part of the total inductance L, and the volume of the inductor can be made quite small, on the order of 1 //m 3 .As is done with other superconducting detectors, trapping could be used to concentrate the quasiparticles into the small volume of the inductor.However, the most intriguing aspect of the concept is that passive frequency multiplexing could be used to read out ~ 10 3 detectors with a single HEMT amplifier. DETECTOR CONCEPTKinetic inductance detectors operate on the principle that a change in the number of quasiparticles in a superconductor will produce a change in the kinetic inductance.This occurs because the quasiparticles block Cooper pairs from occupying some of the electron states.Photons (or particles) are absorbed in the superconductor, producing quasiparticles, and the resulting change in the inductance is measured to produce the detector output.Bolometric detectors using kinetic inductance thermometers have been previously suggested [1, 2, 3, 4, 5, 6].However, such thermometers must be operated close to T c , since the variation of the kinetic inductance with temperature is most rapid near T c , and vanishes exponentially at low temperatures.Although it has been discussed previously [7], it is not widely appreciated that the the variation of the kinetic inductance with energy or quasiparticle number is actually fairly constant down to very low temperatures.The idea, then, is to use the kinetic inductance effect to read out changes in the quasiparticle population produced by the direct absorbtion of pair-breaking photons rather than changes in the temperature of the phonons in a bolometric absorber.How can one measure the change in the kinetic inductance of a superconductor?One way is to make the superconductor act as an inductive element in a resonant circuit.A change in the quasiparticle population will change the inductance of the superconductor, and therefore the resonance frequency of the circuit, which can be monitored by measuring the transmission phase of a constant-frequency microwave probe signal transmitted through (or reflected from) the resonator.This method is extremely attractive, due both to CP605, Low Temperature Detectors, edited by F. S. Porter et al.
While experimental studies of kinetic-inductance sensors have been limited so far by the temperature range near the superconducting transition, these detectors can be very sensitive at temperatures well below the transition, where the number of equilibrium quasiparticles is exponentially small. In this regime, a shift of the quasiparticle chemical potential under radiation results in the change of the kinetic inductance, which can be measured by a sensitive SQUID readout. We modeled the kinetic inductance response of detectors made from disordered superconducting Nb, NbC, and MoRe films. Low phonon transparency of the interface between the superconductor and the substrate causes substantial re-trapping of phonons providing high quantum efficiency and the operating time of ∼1 ms at ≈1 K. Due to the small number of quasiparticles, the noise equivalent power of the detector determined by the quasiparticle generation-recombination noise can be as small as ∼10−19 W/√Hz at He4 temperatures.
Low temperature Kinetic Inductance Detectors (KIDs) are attractive candidates for producing quantumsensitive, arrayable sensors for astrophysical and other precision measurement applications. The readout uses a low frequency probe signal with quanta of energy well-below the threshold for pair-breaking in the superconductor. We have calculated the detailed non-equilibrium quasiparticle and phonon energy spectra generated by the probe signal of the KID when operating well-below its superconducting transition temperature Tc within the framework of the coupled kinetic equations described by Chang and Scalapino.[1] At the lowest bath temperature studied Tb/Tc = 0.1 the quasiparticle distributions can be driven far from equilibrium. In addition to the low frequency probe signal we have incorporated a high frequency (~ 1 THz) source signal well-above the pair-breaking threshold of the superconductor. Calculations of source signal detection efficiency are discussed
We present a theoretical model of a superconducting kinetic inductance detector which promises high sensitivity and energy resolution from submillimetre to X-ray wavelengths. Cooper-pair breaking photons are absorbed in a superconductor, exciting quasiparticles which change the surface inductance. By arranging the detector in a resonant circuit we can measure the resulting phase-shift of a microwave probe signal. Software has been created to model the superconducting characteristics of the detector and its behaviour when a photon is absorbed. The model predicts the position sensitivity of the detector and calculates how quasiparticles diffuse and recombine to a thermal background level. This temporal evolution of quasiparticle dynamics gives rise to a measurable phase-shift pulse, which will allow the energy and time of a photon to be measured. Pulse shapes have been simulated for photon energies of 1-5 keV being absorbed at the sensitive ground-end of the detector.
Superconducting detectors are a modern technology applied in various fields. The microwave kinetic inductance detector (MKID) is one of the cutting-edge superconducting detectors. It is based on the principle of a superconducting resonator circuit. A radiation entering the MKID breaks the Cooper pairs in the superconducting resonator, and the intensity of the radiation is detected as a variation of the resonant condition. Therefore, calibration of the detector responsivity, i.e., the variation of the resonant phase with respect to the number of Cooper-pair breaks (quasiparticles), is important. We propose a method for responsivity calibration. Microwaves used for the detector readout locally raise the temperature in each resonator, which increases the number of quasiparticles. Since the magnitude of the temperature rise depends on the power of readout microwaves, the number of quasiparticles also depends on the power of microwaves. By changing the power of the readout microwaves, we simultaneously measure the phase difference and lifetime of quasiparticles. We calculate the number of quasiparticles from the measured lifetime and by using a theoretical formula. This measurement yields a relation between the phase responses as a function of the number of quasiparticles. We demonstrate this responsivity calibration using the MKID maintained at 285 mK. We also confirm the consistency between the results obtained using this method and conventional calibration methods in terms of the accuracy.
A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.
Extremely sensitive far-infrared detectors suitable for both direct detection and heterodyne applications, based on mu m-sized thin films with thickness less than a superconducting penetration depth are possible. The penetration depth of such a film, and therefore its inductance, varies with temperature and with quasiparticle population (described by an effective temperature T*), resulting in both bolometric and nonequilibrium photoinductive responses. Incident radiation is coupled into the small-area kinetic inductor by a lithographic antenna, and the resulting inductance changes are amplified and converted to a voltage signal by an integrated microstrip DC SQUID. The device is sensitive because, unlike junction-based devices with large capacitive reactances, the kinetic inductor is naturally well matched to the antenna impedance at the far-IR frequency ( nu >2 Delta /h) and to the preamplifier (SQUID) impedance at microwave or video frequencies ( nu <<2 Delta /h). The best kinetic inductor materials are those with low electronic mean free path, large penetration depth, and high critical current density. Thus, common magnet alloys such as NbTi are the natural choice for liquid-He temperature operation. A detailed analysis predicts a (phonon-limited) NEP of 4*10/sup -17/ W/ square root Hz for a bolometer with an iridium kinetic inductor operated at 0.1 K. A heterodyne noise temperature of 2250 K (single-sideband) at 3 THz, with a 200-MHz bandwidth, is predicted for a Nb-Ti mixer operated at 4 K.