Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

The effects of path absorption on phase sensitivity with entangled states

Yang Gao, Hwang Lee

Published Feb 7, 2008• 0 citations
Publisher

Abstract

It is known that the phase measurement using lossless Mach-Zehnder interferometer with certain entangled N-photon states can achieve a phase sensitivity of the order of 1/N, the Heisenberg limit. However, the output observable used is different for different input states to achieve the Heisenberg limit. In this paper, we show that it is possible to achieve this limit just by parity measurement for all the commonly proposed entangled states. Taking account of path absorption effect, the phase shifts with parity measurement for these states are obtained and indicate that the N00N state still remains to be the best candidate to perform phase detection if the transmittance of the medium is not too small and the number of photons is not very large.

DOI
10.1117/12.762353

Related papers

Sub-shot-noise quantum optical interferometry: a comparison of entangled state performance within a unified measurement scheme

Yang Gao, Hwang Lee

Phase measurement using a lossless Mach–Zehnder interferometer with certain entangled N-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are different for different input states to achieve this limit. We show that it is possible to achieve this limit just by the parity measurement for all the commonly proposed entangled states. Based on the parity measurement scheme, the reductions of the phase sensitivity in the presence of photon loss are examined for the various input states.

arXiv:0803.0155•Journal of Modern Optics•Nov 10, 2008•17 citations

Optical interferometry at the Heisenberg limit with twin Fock states and parity measurements

Richard A. Campos, Christopher C. Gerry, Adil Benmoussa

Holland and Burnett [Phys. Rev. Lett. 71, 1355 (1993)] have argued that twin Fock states of equal photon number $N$ injected at both input ports of a Mach-Zehnder interferometer lead to phase measurements with accuracies approaching the Heisenberg limit $\ensuremath{\Delta}{\ensuremath{\varphi}}_{\mathrm{HL}}=1/(2N).$ However, the method of phase detection suggested by those authors, obtaining the difference of the photocurrents at the output ports of the interferometer, is not sensitive to the phase difference between the two interferometer paths; in fact, the photocurrent vanishes. In this paper we show that the use of parity measurements on just one of the output modes not only is sensitive to the phase difference but that the sensitivity approaches the Heisenberg limit for large $N.$

Physical Review A•Aug 25, 2003•230 citations

Phase sensitivity of a Mach-Zehnder interferometer

Luca Pezzè, Augusto Smerzi

The best performance of a Mach-Zehnder interferometer is achieved with the input state $\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩+\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩$, ${N}_{T}$ being the total number of atoms or photons. This gives (i) a phase-shift error confidence ${C}_{68%}=2.67∕{N}_{T}$ with (ii) a single interferometric measurement. Different input quantum states can achieve the Heisenberg scaling $\ensuremath{\sim}1∕{N}_{T}$ but with higher prefactors and at the price of a statistical analysis of two or more independent measurements.

arXiv:quant-ph/0511059•Physical Review A•Jan 3, 2006•87 citations

Parity measurements, Heisenberg-limited phase estimation, and beyond

Christopher C. Gerry, Adil Benmoussa, Richard A. Campos

We review the use of parity measurements to obtain Heisenberg-limited phase shift measurements from interferometry performed with maximally path entangled two mode states containing N photons, contrasting this measure with the method of coincidence detection which requires a number of such detections that scales with N. For large N, coincidence measurements will become impractical. In contrast, the parity method we propose is independent of N. In addition, with the parity approach, one can use an entanglement of a coherent state and the vacuum to approach the Heisensberg limit of phase resolution without the requirement of first producing a Fock state of large photon number. We also show in a very simple way, using Maximally entangled states and parity measurements that it is possible to go beyond the Heisenberg limit if the phase shifts are generated by a nonlinear Kerr-like interaction.

Journal of Modern Optics•Sep 10, 2007•25 citations

Phase sensitivity of a quantum Mach-Zehnder interferometer for a coherent state input

Taesoo Kim, Heonoh Kim

The phase sensitivity of a Mach-Zehnder interferometer utilizing quantum entanglement is analyzed for a coherent state input. The results show that the Heisenberg limit in the measurement of the phase shift is obtainable with a coherent input. Moreover, the scheme turns out to be immune to the imperfect detector efficiencies. This suggests another promising route for implementing sub-shot-noise measurement schemes.

Journal of the Optical Society of America B•Mar 12, 2009•10 citations

Dispersion and fidelity in quantum interferometry

David S. Simon, Alexander V. Sergienko, Thomas B. Bahder

We consider Mach-Zehnder and Hong-Ou-Mandel interferometers with nonclassical states of light as input, and study the effect that dispersion inside the interferometer has on the sensitivity of phase measurements. We study in detail a number of different one- and two-photon input states, including Fock, dual Fock, maximally path-entangled $\ensuremath{\mid}N,0⟩+⟨{0}_{,}N\ensuremath{\mid}$ (``N00N'') states, and photon pairs from parametric down-conversion. Assuming there is a phase shift ${\ensuremath{\phi}}_{0}$ in one arm of the interferometer, we compute the probabilities of measurement outcomes as a function of ${\ensuremath{\phi}}_{0}$, and then compute the Shannon mutual information between ${\ensuremath{\phi}}_{0}$ and the measurements. This provides a means of quantitatively comparing the utility of various input states for determining the phase in the presence of dispersion. In addition, we consider a simplified model of parametric down-conversion for which probabilities can be explicitly computed analytically, and which serves as a limiting case of the more realistic down-conversion model.

arXiv:0810.4501•Physical Review A•Nov 26, 2008•8 citations
It is known that the phase measurement using lossless Mach-Zehnder interferometer with certain entangled N-photon states can achieve a phase sensitivity of the order of 1/N, the Heisenberg limit. However, the output observable used is different for different input states to achieve the Heisenberg limit. In this paper, we show that it is possible to achieve this limit just by parity measurement for all the commonly proposed entangled states. Taking account of path absorption effect, the phase shifts with parity measurement for these states are obtained and indicate that the N00N state still remains to be the best candidate to perform phase detection if the transmittance of the medium is not too small and the number of photons is not very large.
Phase measurement using a lossless Mach–Zehnder interferometer with certain entangled N-photon states can lead to a phase sensitivity of the order of 1/N, the Heisenberg limit. However, previously considered output measurement schemes are different for different input states to achieve this limit. We show that it is possible to achieve this limit just by the parity measurement for all the commonly proposed entangled states. Based on the parity measurement scheme, the reductions of the phase sensitivity in the presence of photon loss are examined for the various input states.
Holland and Burnett [Phys. Rev. Lett. 71, 1355 (1993)] have argued that twin Fock states of equal photon number NNN injected at both input ports of a Mach-Zehnder interferometer lead to phase measurements with accuracies approaching the Heisenberg limit $\ensuremath{\Delta}{\ensuremath{\varphi}}_{\mathrm{HL}}=1/(2N).$ However, the method of phase detection suggested by those authors, obtaining the difference of the photocurrents at the output ports of the interferometer, is not sensitive to the phase difference between the two interferometer paths; in fact, the photocurrent vanishes. In this paper we show that the use of parity measurements on just one of the output modes not only is sensitive to the phase difference but that the sensitivity approaches the Heisenberg limit for large N.N.N.
The best performance of a Mach-Zehnder interferometer is achieved with the input state $\ensuremath{\mid}{N}_{T}∕2+1⟩\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩+\ensuremath{\mid}{N}_{T}∕2\ensuremath{-}1⟩\ensuremath{\mid}{N}_{T}∕2+1⟩$, NT{N}_{T}NT​ being the total number of atoms or photons. This gives (i) a phase-shift error confidence ${C}_{68%}=2.67∕{N}_{T}$ with (ii) a single interferometric measurement. Different input quantum states can achieve the Heisenberg scaling $\ensuremath{\sim}1∕{N}_{T}$ but with higher prefactors and at the price of a statistical analysis of two or more independent measurements.
We review the use of parity measurements to obtain Heisenberg-limited phase shift measurements from interferometry performed with maximally path entangled two mode states containing N photons, contrasting this measure with the method of coincidence detection which requires a number of such detections that scales with N. For large N, coincidence measurements will become impractical. In contrast, the parity method we propose is independent of N. In addition, with the parity approach, one can use an entanglement of a coherent state and the vacuum to approach the Heisensberg limit of phase resolution without the requirement of first producing a Fock state of large photon number. We also show in a very simple way, using Maximally entangled states and parity measurements that it is possible to go beyond the Heisenberg limit if the phase shifts are generated by a nonlinear Kerr-like interaction.
We consider Mach-Zehnder and Hong-Ou-Mandel interferometers with nonclassical states of light as input, and study the effect that dispersion inside the interferometer has on the sensitivity of phase measurements. We study in detail a number of different one- and two-photon input states, including Fock, dual Fock, maximally path-entangled $\ensuremath{\mid}N,0⟩+⟨{0}_{,}N\ensuremath{\mid}$ (``N00N'') states, and photon pairs from parametric down-conversion. Assuming there is a phase shift ${\ensuremath{\phi}}_{0}$ in one arm of the interferometer, we compute the probabilities of measurement outcomes as a function of ${\ensuremath{\phi}}_{0}$, and then compute the Shannon mutual information between ${\ensuremath{\phi}}_{0}$ and the measurements. This provides a means of quantitatively comparing the utility of various input states for determining the phase in the presence of dispersion. In addition, we consider a simplified model of parametric down-conversion for which probabilities can be explicitly computed analytically, and which serves as a limiting case of the more realistic down-conversion model.