Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Soviet Journal of Quantum Electronics

Laser converter with modified pumping and frequency-squeezed noise

Andrey V. Gusev, Victor V. Kulagin

Published Aug 31, 1988• 2 citations
Publisher

Abstract

A new principle of a parametric optical amplifier of the reflection type with a controlled backward wave is proposed. The excess noise in such a laser converter, due to zero-point fluctuations of a photodetector acting as a black body absorber, is suppressed by using an additional circulator window which provides coupling to a series of degenerate reflection-type parametric amplifiers tuned to combination frequencies. A squeezed state of the electromagnetic field inside the converter resonator observed at the combination frequencies can be used to detect ultrasmall signals. An expression is obtained for the calculation of the threshold sensitivity.

DOI
10.1070/qe1988v018n08abeh012393

Related papers

Phase-Sensitive Manipulations of a Squeezed Vacuum Field in an Optical Parametric Amplifier inside an Optical Cavity

Jing Zhang, Chenguang Ye, Gao Feng +1 more

A squeezed vacuum field can be amplified or deamplified when it is injected, as the signal beam, into a phase-sensitive optical parametric amplifier (OPA) inside an optical cavity. The spectral features of the reflected quantized signal field are controlled by the relative phase between the injected squeezed vacuum field and the pump field for the OPA. The experimental results demonstrate coherent phenomena of OPA in the quantum regime and show phase-sensitive manipulations of quantum fluctuations for quantum information processing.

arXiv:0811.0161•Physical Review Letters•Dec 1, 2008•47 citations

Degenerate parametric oscillator

P. D. Drummond, Mark S. Hillery

The optical parametric oscillator is one of the most well-characterized devices in nonlinear optics, with many useful applications, especially as a frequency converter and as a wide-band amplifier. Novel discoveries made with these devices in the quantum domain include demonstrations of large amounts of both single-mode and two-mode squeezing, and, in the two-mode case, significant quantum intensity correlations between the two modes and quadrature correlations, which provided the first experimental demonstration of the original Einstein–Podolsky–Rosen (EPR) paradox. In this chapter, a systematic theory is developed of quantum fluctuations in the degenerate parametric oscillator. The quantum statistical effects produced by the degenerate parametric amplifier and oscillator have been intensely studied. As we have seen, the amount of transient squeezing produced in an ideal lossless parametric amplifier was calculated using asymptotic methods by Crouch and Braunstein. It was found to scale inversely with the square root of the initial pump photon number. When the system is put into a cavity, and driving and dissipation are introduced, we find that the steady state of a driven degenerate parametric oscillator bifurcates. There is a single steady state at low driving strengths, but, as the driving field increases, a threshold value is reached and the single state splits and forms two stable states. Below the threshold, a linearized analysis of squeezing in the quantum quadratures is possible; while above this threshold, or critical point, the tunneling time between the two states due to quantum fluctuations can be calculated.

Cambridge University Press eBooks•Mar 27, 2014•0 citations

Effect of laser fluctuations on squeezed states in a degenerate parametric amplifier

K. Wódkiewicz, Muhammad Suhail Zubairy

The effect of phase and amplitude fluctuations of the pump mode on the quantum-statistical properties of the signal mode is considered. It is shown that these fluctuations in the laser field tend to decrease the squeezing of the signal field.

Physical Review A•Apr 1, 1983•78 citations

Quantum-noise reduction with a Q-switched laser

Orhan Aytür, Prem Kumar

Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.

Annual Meeting Optical Society of America•Jan 1, 1990•0 citations

Raman-effect induced noise limits on (3)parametric amplifiers and wavelength converters

Paul L. Voss, Prem Kumar

The non-zero response time of the Kerr (χ (3) ) nonlinearity determines the quantum-limited noise figure of χ (3) parametric amplifiers and wavelength converters. This non-zero response time of the nonlinearity requires coupling of the parametric amplification process to a molecular-vibration phonon bath, causing the addition of excess noise through Raman gain or loss. The effect of this excess noise on the noise figure of the amplifier can be significant. We derive analytical expressions for this quantum-limited noise figure in the case of non-degenerate phase-insensitive operation of a χ (3) parametric amplifier and show excellent agreement with experiment without any fitting parameter. We also derive analytical expressions for the quantum limited noise figure for χ (3) -based wavelength converters.

Journal of Optics B Quantum and Semiclassical Optics•Jul 28, 2004•48 citations

Generation of bright squeezed light at 1.06 $μm$ using cascaded non-linearities in a triply resonant c.w. PPLN OPO

Zhang, K. S., T. Coudreau, M. Martinelli +2 more

We have used an ultra-low threshold continuous-wave Optical Parametric Oscillator (OPO) to reduce the quantum fluctuations of the reflected pump beam below the shot noise limit. The OPO consisted of a triply resonant cavity containing a Periodically-Poled Lithium Niobate crystal pumped by a Nd:YAG laser and giving signal and idler wavelengths close to 2.12 microns and a threshold as low as 300 microwatts. We detected the quantum fluctuations of the pump beam reflected by the OPO using a slightly modified homodyne detection technique. The measured noise reduction was 30 % (inferred noise reduction at the output of the OPO 38 %).

arXiv:quant-ph/0105148•May 30, 2001•0 citations
A new principle of a parametric optical amplifier of the reflection type with a controlled backward wave is proposed. The excess noise in such a laser converter, due to zero-point fluctuations of a photodetector acting as a black body absorber, is suppressed by using an additional circulator window which provides coupling to a series of degenerate reflection-type parametric amplifiers tuned to combination frequencies. A squeezed state of the electromagnetic field inside the converter resonator observed at the combination frequencies can be used to detect ultrasmall signals. An expression is obtained for the calculation of the threshold sensitivity.
A squeezed vacuum field can be amplified or deamplified when it is injected, as the signal beam, into a phase-sensitive optical parametric amplifier (OPA) inside an optical cavity. The spectral features of the reflected quantized signal field are controlled by the relative phase between the injected squeezed vacuum field and the pump field for the OPA. The experimental results demonstrate coherent phenomena of OPA in the quantum regime and show phase-sensitive manipulations of quantum fluctuations for quantum information processing.
The optical parametric oscillator is one of the most well-characterized devices in nonlinear optics, with many useful applications, especially as a frequency converter and as a wide-band amplifier. Novel discoveries made with these devices in the quantum domain include demonstrations of large amounts of both single-mode and two-mode squeezing, and, in the two-mode case, significant quantum intensity correlations between the two modes and quadrature correlations, which provided the first experimental demonstration of the original Einstein–Podolsky–Rosen (EPR) paradox. In this chapter, a systematic theory is developed of quantum fluctuations in the degenerate parametric oscillator. The quantum statistical effects produced by the degenerate parametric amplifier and oscillator have been intensely studied. As we have seen, the amount of transient squeezing produced in an ideal lossless parametric amplifier was calculated using asymptotic methods by Crouch and Braunstein. It was found to scale inversely with the square root of the initial pump photon number. When the system is put into a cavity, and driving and dissipation are introduced, we find that the steady state of a driven degenerate parametric oscillator bifurcates. There is a single steady state at low driving strengths, but, as the driving field increases, a threshold value is reached and the single state splits and forms two stable states. Below the threshold, a linearized analysis of squeezing in the quantum quadratures is possible; while above this threshold, or critical point, the tunneling time between the two states due to quantum fluctuations can be calculated.
Pulsed squeezed light and intensity-correlated twin beams are generated by means of a traveling-wave optical parametric amplifier (OPA) consisting of a type-II phase-matched KTiOPO4 crystal that is pumped by a Q-switched and frequency-doubled Nd:YAG laser. Q switching of the laser results in a high peak pump intensity and a large peak parametric gain. Squeezed light is generated by amplifying the vacuum input field to the OPA, and it is detected by a balanced homodyne configuration that uses the fundamental beam of the laser as a local oscillator.1 Twin beams are generated by supplying a small input signal to the OPA. The amplified signal and idler beams are direct-detected individually and yield quantum-noise reduction when the two photocurrents are subtracted.
The non-zero response time of the Kerr (χ (3) ) nonlinearity determines the quantum-limited noise figure of χ (3) parametric amplifiers and wavelength converters. This non-zero response time of the nonlinearity requires coupling of the parametric amplification process to a molecular-vibration phonon bath, causing the addition of excess noise through Raman gain or loss. The effect of this excess noise on the noise figure of the amplifier can be significant. We derive analytical expressions for this quantum-limited noise figure in the case of non-degenerate phase-insensitive operation of a χ (3) parametric amplifier and show excellent agreement with experiment without any fitting parameter. We also derive analytical expressions for the quantum limited noise figure for χ (3) -based wavelength converters.
Generation of bright squeezed light at 1.06 μmμmμm using cascaded non-linearities in a triply resonant c.w. PPLN OPO
We have used an ultra-low threshold continuous-wave Optical Parametric Oscillator (OPO) to reduce the quantum fluctuations of the reflected pump beam below the shot noise limit. The OPO consisted of a triply resonant cavity containing a Periodically-Poled Lithium Niobate crystal pumped by a Nd:YAG laser and giving signal and idler wavelengths close to 2.12 microns and a threshold as low as 300 microwatts. We detected the quantum fluctuations of the pump beam reflected by the OPO using a slightly modified homodyne detection technique. The measured noise reduction was 30 % (inferred noise reduction at the output of the OPO 38 %).