Optics Letters

High sensitivity third-order autocorrelation measurement by intensity modulation and third harmonic detection

Yizhen Wei, Scott S. Howard, Adam A. Straub, Zinan Wang, Ji Cheng, Shiming Gao, Chris Xu

Published Jun 15, 2011• 15 citations
Publisher

Abstract

We demonstrate a novel (to our knowledge) method for high sensitivity measurement of pulsed light at the telecommunication wavelength of 1558 nm using a GaAsP photomultiplier tube. By modulating the input power and analyzing the harmonic components, high sensitivity third-order autocorrelation is obtained in the wavelength and power regimes where a mixture of two-photon absorption and three-photon absorption in the photomultiplier tube is present.

DOI
10.1364/ol.36.002372

Related papers

Interferometric autocorrelation in the ultraviolet utilizing spontaneous parametric down-conversion inside an enhancement cavity

Patrick Michelberger, Roland Krischek, Witlef Wieczorek +2 more

Autocorrelation is a common method to estimate the duration of ultrashort laser pulses. In the ultraviolet (UV) regime it is challenging to employ the process of second-harmonic generation, most prominently due to absorption in nonlinear crystals at very short wavelengths. Here we show how to utilize spontaneous parametric down-conversion (SPDC) to generate an autocorrelation signal in the infrared (IR) for UV pulses. Our method utilizes the nth-order emission of the SPDC process, which occurs for low pumping powers proportional to the nth power of the UV intensity. Thus, counting 2n down-converted photons directly yields the nth-order autocorrelation. The method, now with detection of near-IR photons, is applied to the first direct measurement of ultrashort UV pulses circulating inside a UV enhancement cavity.

arXiv:1706.01110•Optics Letters•Mar 27, 2012•3 citations

Femtosecond Three-Photon Counting in a Photomultiplier Tube

Amir Nevet, Alex Hayat, Meir Orenstein

We demonstrate experimentally ultrafast three-photon counting by three-photon absorption in a photomultiplier tube, which may serve as a unique tool for ultrafast quantum state characterization as well as for ultrasensitive temporal measurements.

Advanced Photonics•Jan 1, 2011•0 citations

Three-photon counting in a photomultiplier tube for ultrafast source characterization

Amir Nevet, Alex Hayat, Meir Orenstein

We demonstrate experimentally ultrafast three-photon counting by three-photon absorption in a photomultiplier tube, which may serve as a unique tool for ultrafast quantum state characterization as well as for ultrasensitive temporal measurements.

Conference on Lasers and Electro-Optics•Jan 1, 2011•0 citations

Ultrasensitive N -Photon Interferometric Autocorrelator

Zili Zhou, G. Frucci, F. Mattioli +5 more

We demonstrate a novel method to measure Nth-order (N=1,2,3,4) interferometric autocorrelation with high sensitivity and temporal resolution. It is based on the combination of linear absorption and nonlinear detection in a superconducting nanodetector, providing much higher efficiency than methods based on all-optical nonlinearities. Its temporal resolution is only limited by the quasiparticle energy relaxation time, which is directly measured to be in the 20 ps range for the NbN films used in this work. We present a general model of interferometric autocorrelation with these nonlinear detectors and discuss the comparison with other approaches and possible improvements.

arXiv:1209.2747•Physical Review Letters•Mar 28, 2013•25 citations

Detection and spectral measurement of single photons in communication bands using up-conversion technology

Long Ma, Oliver Slattery, Xiao Hong Tang

Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.

Laser Physics•Apr 2, 2010•12 citations

Third harmonic generation by two-photon interaction of high-power coherent light pulses with resonant media

I A Poluéktov

An analysis is made of the influence of third harmonic generation and parametric interaction on twophoton coherent effects which occur during propagation of high-power light pulses through resonant media. It is shown that third harmonic pulses can be generated in this way.

Soviet Journal of Quantum Electronics•Mar 31, 1977•4 citations
We demonstrate a novel (to our knowledge) method for high sensitivity measurement of pulsed light at the telecommunication wavelength of 1558 nm using a GaAsP photomultiplier tube. By modulating the input power and analyzing the harmonic components, high sensitivity third-order autocorrelation is obtained in the wavelength and power regimes where a mixture of two-photon absorption and three-photon absorption in the photomultiplier tube is present.
Autocorrelation is a common method to estimate the duration of ultrashort laser pulses. In the ultraviolet (UV) regime it is challenging to employ the process of second-harmonic generation, most prominently due to absorption in nonlinear crystals at very short wavelengths. Here we show how to utilize spontaneous parametric down-conversion (SPDC) to generate an autocorrelation signal in the infrared (IR) for UV pulses. Our method utilizes the nth-order emission of the SPDC process, which occurs for low pumping powers proportional to the nth power of the UV intensity. Thus, counting 2n down-converted photons directly yields the nth-order autocorrelation. The method, now with detection of near-IR photons, is applied to the first direct measurement of ultrashort UV pulses circulating inside a UV enhancement cavity.
We demonstrate a novel method to measure Nth-order (N=1,2,3,4) interferometric autocorrelation with high sensitivity and temporal resolution. It is based on the combination of linear absorption and nonlinear detection in a superconducting nanodetector, providing much higher efficiency than methods based on all-optical nonlinearities. Its temporal resolution is only limited by the quasiparticle energy relaxation time, which is directly measured to be in the 20 ps range for the NbN films used in this work. We present a general model of interferometric autocorrelation with these nonlinear detectors and discuss the comparison with other approaches and possible improvements.
Quantum information systems are commonly operated in conventional communication bands (1310 and 1550 nm) over an optical fiber to take advantage of low transmission loss. However, the detection and spectral measurement of single photons in these communication bands are limited due to high noise and low sensitivity of single photon detectors in the wavelength ranges. To demonstrate high efficiency detection and high sensitivity spectral measurement, we have implemented a single photon detector and a spectrometer based on frequency up-conversion technology. This detector and spectrometer uses a 5-cm periodically poled lithium niobate (PPLN) waveguide and a tunable pump laser around 1550 nm, to convert signal photons around 1310 to 710 nm. The converted photons are then detected by a silicon-based avalanche photodiode (APD). The overall detection efficiency of the single photon detector is as high as 32%, which is three times higher than commercial InGaAs APDs. The sensitivity of the spectrometer is measured to be −126 dBm, which is at least three orders-of-magnitude better than any commercial optical spectrum analyzer in this wavelength range.