Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Laser radar with atomic vapor ultranarrowband image detectors (UBID)

Oleg I. Matveev, Benjamin W. Smith, James D. Winefordner

Published Sep 8, 1998• 2 citations
Publisher

Abstract

The basic characteristics, figures of merit and potential applications of laser radar with atomic vapor ultra- narrowband imaging detectors (UBID) are discussed. One of the most important figures of merit of a narrowband imaging spectrometer used in a laser radar is the product of throughput and spectral resolution. The atomic vapor UBID, compared with all known spectral imaging instruments, can potentially have a throughput-resolution product up to a million times greater. It is theoretically shown that despite hyperfine structure, one can have smooth characteristics well-suited for an ultranarrowband resonance ionization image detector (RIID) by choosing an appropriate ionization scheme for Cs atoms using the 894.3 nm line. Recent experiments with a vacuum cell mercury atomic vapor RIID are described.

DOI
10.1117/12.327187

Related papers

Narrow-band resonance-ionization and fluorescence imaging in a mercury-vapor cell

Oleg I. Matveev, Benjamin W. Smith, James D. Winefordner

Characteristics of a novel type of ultranarrow-band image detector have been experimentally studied. The principle of this new imaging approach is to detect a resonance-ionization and (or) fluorescence-imaging signal formed on a thin planar cell filled with atomic vapor. A planar vapor cell with a thickness of 1.6 mm was used for imaging 253.7-nm radiation by Hg atoms. One- and two-dimensional images were produced and detected with ionization and fluorescence-signal acquisition. The feasibility of atomic-vapor image detectors with a spectral resolution of several megahertz is discussed.

Optics Letters•Feb 15, 1998•18 citations

Resonance ionization image detectors: basic characteristics and potential applications

Oleg I. Matveev, Benjamin W. Smith, James D. Winefordner

A type of spectrally selective imaging optical detector that is based on resonance ionization in an atomic vapor is proposed. It has the potential for improved spatial, spectral, and temporal resolutions compared with those of available techniques. Figures of merit are calculated and compared with those of existing techniques. Several potential applications such as the imaging of moving objects, ultrasonic fields, high-energy particle detection, and optical communications are discussed.

Applied Optics•Dec 1, 1997•27 citations

Atomic Line Filter for SDI Applications

Jim Menders, Scott H. Bloom, Eric J. Korevaar +2 more

When optical signals are embedded in background noise, narrowband optical filters are needed for receivers to achieve quantum limited performance. Such is typically the case with daytime optical communications and lidar. Narrowband filtered detectors. with acceptance bands of just a few picometers (pm) and high out of band rejection are well suited for these applications. The main thrust of this program has been the development of two means for narrowband detection: the Fast Atomic Line Filter/ Field Ion Detector (FALF/FID) and the Faraday magneto-optic filter. The FALF/FIDs transduce optical radiation within a narrow band directly into electrical signals. They are laser pumped filters based on the spectroscopy of atomic vapors. We designed, built and tested an infrared FALF/FID with an rise time of under 10 ns and a quantum efficiency of >25%. Faraday filters are imaging magneto-optic filters with passbands of a few pm. Faraday filters with passbands in the visable and the near infra-red were constructed and tested. Transmission spectra were measured, and found to agree closely with theoretical predictions. Both of these narrowband detection schemes must be used in conjunction with a tuned narrowband laser source. We developed a frequency locked alexandrite laser designed to match the acceptance band of a rubidium based filter. Finally, a preliminary demonstration of a laser interrogator using a tuned infrared diode laser in conjunction with a filtered receiver was demonstrated. Atomic line filter, Alkali metal vapor, Faraday filter, Active optical filter, Laser pumped filter, Magneto-optic filter, Laser communications.

Final Report•Apr 13, 1994•0 citations

Atomic resonance filters

Jerry A. Gelbwachs

The atomic resonance filter (ARF) is an ultranarrowband (Q approximately 10/sup 5/-10/sup 6/), large-acceptance-angle, isotropic optical filter. These features make the device ideally suited for applications in which weak laser signals are detected against a continuum background. The filter properties arise from the physical processes of absorption, emission, and internal energy conversion in atomic vapors. The characteristics of the ARF are described and the underlying physics that governs the operation is discussed. Representative examples of passive, active, and IR filters are presented. A metastable ARF that offers improved solar background-limited performance by filtering signals at Fraunhofer wavelengths is described.>

IEEE Journal of Quantum Electronics•Jul 1, 1988•88 citations

Ultrahigh-resolution, frequency-resolved resonance fluorescence imaging with a monoisotopic mercury atom cell

Alexey A Podshivalov, M. R. Shepard, Oleg I. Matveev +2 more

A novel method of ultrahigh-resolution, frequency-resolved imaging using atomic vapor cells is proposed. The method is based on the accurate measurement of the fluorescence signal intensity distribution along the absorption path length when the signal frequency is tuned to a wing of the atomic absorption line. Two-step resonance fluorescence of Hg202 vapor was used for one-dimensional imaging of the Hg resonance radiation at 253.7 nm. An imaging signal with a frequency difference of 500 MHz could be easily distinguished visually and even a frequency difference of 80 MHz could be detected after appropriate processing of the fluorescence imaging signal. Several other novel methods of one- and two-dimensional multifrequency imaging are discussed.

Journal of Applied Physics•Nov 15, 1999•7 citations

High resolution field imaging with atomic vapor cells

Andrew Horsley

In this thesis, I report on the development of imaging techniques in atomic vapor cells. This is a relatively unexplored area, despite the ubiquitous use of imaging in experiments with ultracold atoms. Our main focus is in high resolution imaging of microwave near fields, for which there is currently no satisfactory established technique. We detect microwave fields through Rabi oscillations driven by the microwave on atomic hyperfine transitions. The technique can be easily modified to also image dc magnetic fields. In addition, we have developed techniques to image vapor cell processes such as atomic T1 and T2 relaxation. These provide a new window into vapor cell physics, which we have used to obtain spatially resolved information on Rb interactions with the cell walls, and to estimate the Rb relaxation probability in a collision with the cell wall. \n \nAs a first application of our imaging techniques, we imaged the dc and microwave magnetic fields inside a state-of-the-art vapor cell atomic clock. This new clock characterisation technique should lead to real improvements in clock performance, and is in the process of being adopted by the atomic clock community. \n \nWe have developed a widefield, high resolution imaging setup using a microfabricated vapor cell, which we have used to image microwave and dc magnetic vector fields. With the addition of a 480 nm laser, the setup can be configured to image microwave electric fields. Our camera-based imaging system records 2D images with a 6x6 mm2 field of view at a rate of 10 Hz. It provides up to 50 um spatial resolution, and allows imaging of fields as close as 150 um above structures, through the use of extremely thin external cell walls. This is crucial in allowing us to take practical advantage of the high spatial resolution, as feature sizes in near-fields are on the order of the distance from their source, and represents an order of magnitude improvement in surface-feature resolution compared to previous vapor cell experiments. We demonstrate a microwave magnetic field sensitivity of 1.4 uT/sqrt-Hz per 50x50x140 um3 voxel, at present limited by the speed of our imaging system. Since we image 120x120 voxels in parallel, a single scanned sensor would require a sensitivity of at least 12 nT/sqrt-Hz to produce images with the same sensitivity. \n \nThe spatial resolution, distance of approach, and sensitivity of our high resolution setup are sufficient for characterising 6.8 GHz microwave fields above a range of real world devices. However, frequency tunability is essential for wider applications of our imaging technique. Industry is particularly interested in techniques for imaging high frequency microwaves, above 18 GHz, where simulations become increasingly unreliable. I have shown that our technique can be extended to image microwaves of any frequency, in principle from dc to 100s of GHz, by using a large dc magnetic field to Zeeman shift the hyperfine ground state transitions to the desired frequency. I present results from a proof-of-principle setup, where we have used a 0.8 T solenoid to detect and image microwaves from 2.3 GHz to 26.4 GHz. \n

•Jan 1, 2015•1 citation
The basic characteristics, figures of merit and potential applications of laser radar with atomic vapor ultra- narrowband imaging detectors (UBID) are discussed. One of the most important figures of merit of a narrowband imaging spectrometer used in a laser radar is the product of throughput and spectral resolution. The atomic vapor UBID, compared with all known spectral imaging instruments, can potentially have a throughput-resolution product up to a million times greater. It is theoretically shown that despite hyperfine structure, one can have smooth characteristics well-suited for an ultranarrowband resonance ionization image detector (RIID) by choosing an appropriate ionization scheme for Cs atoms using the 894.3 nm line. Recent experiments with a vacuum cell mercury atomic vapor RIID are described.
Characteristics of a novel type of ultranarrow-band image detector have been experimentally studied. The principle of this new imaging approach is to detect a resonance-ionization and (or) fluorescence-imaging signal formed on a thin planar cell filled with atomic vapor. A planar vapor cell with a thickness of 1.6 mm was used for imaging 253.7-nm radiation by Hg atoms. One- and two-dimensional images were produced and detected with ionization and fluorescence-signal acquisition. The feasibility of atomic-vapor image detectors with a spectral resolution of several megahertz is discussed.
When optical signals are embedded in background noise, narrowband optical filters are needed for receivers to achieve quantum limited performance. Such is typically the case with daytime optical communications and lidar. Narrowband filtered detectors. with acceptance bands of just a few picometers (pm) and high out of band rejection are well suited for these applications. The main thrust of this program has been the development of two means for narrowband detection: the Fast Atomic Line Filter/ Field Ion Detector (FALF/FID) and the Faraday magneto-optic filter. The FALF/FIDs transduce optical radiation within a narrow band directly into electrical signals. They are laser pumped filters based on the spectroscopy of atomic vapors. We designed, built and tested an infrared FALF/FID with an rise time of under 10 ns and a quantum efficiency of >25%. Faraday filters are imaging magneto-optic filters with passbands of a few pm. Faraday filters with passbands in the visable and the near infra-red were constructed and tested. Transmission spectra were measured, and found to agree closely with theoretical predictions. Both of these narrowband detection schemes must be used in conjunction with a tuned narrowband laser source. We developed a frequency locked alexandrite laser designed to match the acceptance band of a rubidium based filter. Finally, a preliminary demonstration of a laser interrogator using a tuned infrared diode laser in conjunction with a filtered receiver was demonstrated. Atomic line filter, Alkali metal vapor, Faraday filter, Active optical filter, Laser pumped filter, Magneto-optic filter, Laser communications.
The atomic resonance filter (ARF) is an ultranarrowband (Q approximately 10/sup 5/-10/sup 6/), large-acceptance-angle, isotropic optical filter. These features make the device ideally suited for applications in which weak laser signals are detected against a continuum background. The filter properties arise from the physical processes of absorption, emission, and internal energy conversion in atomic vapors. The characteristics of the ARF are described and the underlying physics that governs the operation is discussed. Representative examples of passive, active, and IR filters are presented. A metastable ARF that offers improved solar background-limited performance by filtering signals at Fraunhofer wavelengths is described.>
A novel method of ultrahigh-resolution, frequency-resolved imaging using atomic vapor cells is proposed. The method is based on the accurate measurement of the fluorescence signal intensity distribution along the absorption path length when the signal frequency is tuned to a wing of the atomic absorption line. Two-step resonance fluorescence of Hg202 vapor was used for one-dimensional imaging of the Hg resonance radiation at 253.7 nm. An imaging signal with a frequency difference of 500 MHz could be easily distinguished visually and even a frequency difference of 80 MHz could be detected after appropriate processing of the fluorescence imaging signal. Several other novel methods of one- and two-dimensional multifrequency imaging are discussed.
In this thesis, I report on the development of imaging techniques in atomic vapor cells. This is a relatively unexplored area, despite the ubiquitous use of imaging in experiments with ultracold atoms. Our main focus is in high resolution imaging of microwave near fields, for which there is currently no satisfactory established technique. We detect microwave fields through Rabi oscillations driven by the microwave on atomic hyperfine transitions. The technique can be easily modified to also image dc magnetic fields. In addition, we have developed techniques to image vapor cell processes such as atomic T1 and T2 relaxation. These provide a new window into vapor cell physics, which we have used to obtain spatially resolved information on Rb interactions with the cell walls, and to estimate the Rb relaxation probability in a collision with the cell wall. \n \nAs a first application of our imaging techniques, we imaged the dc and microwave magnetic fields inside a state-of-the-art vapor cell atomic clock. This new clock characterisation technique should lead to real improvements in clock performance, and is in the process of being adopted by the atomic clock community. \n \nWe have developed a widefield, high resolution imaging setup using a microfabricated vapor cell, which we have used to image microwave and dc magnetic vector fields. With the addition of a 480 nm laser, the setup can be configured to image microwave electric fields. Our camera-based imaging system records 2D images with a 6x6 mm2 field of view at a rate of 10 Hz. It provides up to 50 um spatial resolution, and allows imaging of fields as close as 150 um above structures, through the use of extremely thin external cell walls. This is crucial in allowing us to take practical advantage of the high spatial resolution, as feature sizes in near-fields are on the order of the distance from their source, and represents an order of magnitude improvement in surface-feature resolution compared to previous vapor cell experiments. We demonstrate a microwave magnetic field sensitivity of 1.4 uT/sqrt-Hz per 50x50x140 um3 voxel, at present limited by the speed of our imaging system. Since we image 120x120 voxels in parallel, a single scanned sensor would require a sensitivity of at least 12 nT/sqrt-Hz to produce images with the same sensitivity. \n \nThe spatial resolution, distance of approach, and sensitivity of our high resolution setup are sufficient for characterising 6.8 GHz microwave fields above a range of real world devices. However, frequency tunability is essential for wider applications of our imaging technique. Industry is particularly interested in techniques for imaging high frequency microwaves, above 18 GHz, where simulations become increasingly unreliable. I have shown that our technique can be extended to image microwaves of any frequency, in principle from dc to 100s of GHz, by using a large dc magnetic field to Zeeman shift the hyperfine ground state transitions to the desired frequency. I present results from a proof-of-principle setup, where we have used a 0.8 T solenoid to detect and image microwaves from 2.3 GHz to 26.4 GHz. \n