Cryogenics

Measurement of the input resistance of a rf biased SQUID

S.S. Tinchev, P. Gutmann

Published Sep 1, 1983• 0 citations
Publisher
DOI
10.1016/0011-2275(83)90003-6

Related papers

Measurement of the input impedance of a rf biased SQUID

Franco Bordoni, I. Modena, Romani G. L. +1 more

•Jan 1, 1979•0 citations

Behavior of the dc Impedance of an rf-Biased Resistive SQUID | NIST

D. Vanechten, Robert J. Soulen, Rick Peterson

•Dec 31, 1980•0 citations

Rf-biased SQUID with half-wavelength transmission line

Thomas W. Bradshaw, William P. Pratt

Cryogenics•Sep 1, 1979•2 citations

Input impedance of the RF SQUID in high frequency regime

S.S. Tinchev

A simple method is developed for analysis of the RF SQUID in regime, where the bias frequency ω is comparable to the natural R/L frequency of the SQUID ring. The input impedance of the RF SQUID is calculated for various values of the parametersq = \omega L/R\leq \leq \pi/4, signal frequency and detuning of the rf bias frequency from tank circuit resonant frequency. It is shown, that both the input resistance and the input inductance may be positive or negative. Measurement of the real part of the input impedance of a hysteretic RF SQUID are described. The experimental data are in qualitative agreement with the prediction of the theory.

IEEE Transactions on Magnetics•May 1, 1983•0 citations

BEHAVIOR OF THE DC IMPEDANCE OF AN RF-BIASED RESISTIVE SQUID

Deborah van Vechten, Robert J. Soulen, Rick Peterson

De Gruyter eBooks•Dec 31, 1980•7 citations

Impedance of radio-frequency-biased resistive superconducting quantum interference devices

Robert J. Soulen, Deborah van Vechten

We have measured with high accuracy (100 ppm) and high precision (5--10 ppm) the impedance of a rf-driven resistive superconducting quantum interference device (SQUID) as a function of the amplitude and frequency of the radio-frequency (rf) bias, as a function of the current bias, and as a function of several other circuit parameters. We have developed the coupled differential equations for the resistive SQUID and for the rf tank circuit. The fit of the solutions of these equations to the data for nonhysteretic junctions is excellent. We were unable to develop solutions for the hysteretic case and thus simply present examples of typical data obtained in order to illustrate the differences with the nonhysteretic case. The relationship of this study to noise thermometry using resistive SQUID's is indicated.

Physical review. B, Condensed matter•Jul 1, 1987•13 citations
A simple method is developed for analysis of the RF SQUID in regime, where the bias frequency ω is comparable to the natural R/L frequency of the SQUID ring. The input impedance of the RF SQUID is calculated for various values of the parametersq = \omega L/R\leq \leq \pi/4, signal frequency and detuning of the rf bias frequency from tank circuit resonant frequency. It is shown, that both the input resistance and the input inductance may be positive or negative. Measurement of the real part of the input impedance of a hysteretic RF SQUID are described. The experimental data are in qualitative agreement with the prediction of the theory.
We have measured with high accuracy (100 ppm) and high precision (5--10 ppm) the impedance of a rf-driven resistive superconducting quantum interference device (SQUID) as a function of the amplitude and frequency of the radio-frequency (rf) bias, as a function of the current bias, and as a function of several other circuit parameters. We have developed the coupled differential equations for the resistive SQUID and for the rf tank circuit. The fit of the solutions of these equations to the data for nonhysteretic junctions is excellent. We were unable to develop solutions for the hysteretic case and thus simply present examples of typical data obtained in order to illustrate the differences with the nonhysteretic case. The relationship of this study to noise thermometry using resistive SQUID's is indicated.