Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physica B Condensed Matter

Frequency noise in hysteretic resistive SQUIDs

S.L. Thomasson

Published Apr 7, 2003• 0 citations
Publisher
DOI
10.1016/s0921-4526(02)02401-8

Related papers

Self-Consistent Theory of the Voltage-Current Characteristic and Intrinsic Noise of the Hysteretic RF-SQUID

Ya. S. Greenberg

Springer proceedings in physics•Jan 1, 1992•0 citations

Self-consistent theory of a voltage-current characteristic and of intrinsic noise of hysteretic RF SQUID

Ya. S. Greenberg

Journal of Low Temperature Physics•Sep 1, 1993•2 citations

Signal-to-Noise Ratio Maximization in Non-hysteretic r.f. and d.c. SQUIDs

Mario A. Inchiosa, Adi R. Bulsara

APS•Mar 1, 1998•0 citations

The hysteretic RF SQUID as reactance and the possibility of a phase-sensitive detection on the RF SQUID

H. Krenn, Reinhold Ernst Schmidt, F. Gross

Applied Physics B•May 1, 1978•1 citation

Impedance of radio-frequency-biased resistive superconducting quantum interference devices

Robert J. Soulen, Deborah van Vechten

We have measured with high accuracy (100 ppm) and high precision (5--10 ppm) the impedance of a rf-driven resistive superconducting quantum interference device (SQUID) as a function of the amplitude and frequency of the radio-frequency (rf) bias, as a function of the current bias, and as a function of several other circuit parameters. We have developed the coupled differential equations for the resistive SQUID and for the rf tank circuit. The fit of the solutions of these equations to the data for nonhysteretic junctions is excellent. We were unable to develop solutions for the hysteretic case and thus simply present examples of typical data obtained in order to illustrate the differences with the nonhysteretic case. The relationship of this study to noise thermometry using resistive SQUID's is indicated.

Physical review. B, Condensed matter•Jul 1, 1987•13 citations

An RF SQUID readout for a flux qubit-based microwave single photon counter

V. I. Shnyrkov, Andrii P. Shapovalov, V. Yu. Lyakhno +3 more

Abstract An analysis of the measurement of the magnetic flux in superconducting qubits based on RF SQUIDs was carried out with an 800 MHz bandwidth low-power-consumption cryogenic high-electron-mobility transistor amplifier. The preliminary experimental results obtained at temperatures 2 K and 4 K for RF SQUIDs in hysteretic, and in two non-hysteretic, regimes with a pump frequency of about 30 MHz are discussed. Parameters of RF SQUIDs in the hysteretic and non-hysteretic modes are analyzed within the framework of the resistively and capacitively shunted junction model for Josephson junctions. Its sensitivity at a temperature of 30 mK and frequency band (speed) are calculated and optimized to read the states of a flux qubit used as a single microwave photon counter. It is shown that an RF SQUID, operated in an adiabatic non-hysteretic mode for qubit readout, allows us to minimize its back-action effect and the dark count rate. This is due to the absence of Josephson generation, the small amplitude of the resonator electromagnetic field, and the selection of the pump frequency that does not coincide with the characteristic frequencies of the flux qubit.

Superconductor Science and Technology•Jan 6, 2023•7 citations
We have measured with high accuracy (100 ppm) and high precision (5--10 ppm) the impedance of a rf-driven resistive superconducting quantum interference device (SQUID) as a function of the amplitude and frequency of the radio-frequency (rf) bias, as a function of the current bias, and as a function of several other circuit parameters. We have developed the coupled differential equations for the resistive SQUID and for the rf tank circuit. The fit of the solutions of these equations to the data for nonhysteretic junctions is excellent. We were unable to develop solutions for the hysteretic case and thus simply present examples of typical data obtained in order to illustrate the differences with the nonhysteretic case. The relationship of this study to noise thermometry using resistive SQUID's is indicated.
Abstract An analysis of the measurement of the magnetic flux in superconducting qubits based on RF SQUIDs was carried out with an 800 MHz bandwidth low-power-consumption cryogenic high-electron-mobility transistor amplifier. The preliminary experimental results obtained at temperatures 2 K and 4 K for RF SQUIDs in hysteretic, and in two non-hysteretic, regimes with a pump frequency of about 30 MHz are discussed. Parameters of RF SQUIDs in the hysteretic and non-hysteretic modes are analyzed within the framework of the resistively and capacitively shunted junction model for Josephson junctions. Its sensitivity at a temperature of 30 mK and frequency band (speed) are calculated and optimized to read the states of a flux qubit used as a single microwave photon counter. It is shown that an RF SQUID, operated in an adiabatic non-hysteretic mode for qubit readout, allows us to minimize its back-action effect and the dark count rate. This is due to the absence of Josephson generation, the small amplitude of the resonator electromagnetic field, and the selection of the pump frequency that does not coincide with the characteristic frequencies of the flux qubit.