Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Generation of Squeezed States by Parametric Down Conversion

Ling-An Wu, Harry J. Kimble, J. L. Hall, Huifa Wu

Published Nov 17, 1986• 1,652 citations
Publisher

Abstract

Squeezed states of the electromagnetic field are generated by degenerate parametric down conversion in an optical cavity. Noise reductions greater than 50% relative to the vacuum noise level are observed in a balanced homodyne detector. A quantitative comparison with theory suggests that the observed squeezing results from a field that in the absence of linear attenuation would be squeezed by greater then tenfold.

DOI
10.1103/physrevlett.57.2520

Related papers

Squeezed states of light from an optical parametric oscillator

Ling-An Wu, Min Xiao, Harry J. Kimble

Squeezed states of the electromagnetic field are generated by degenerate parametric downconversion in a sub-threshold optical parametric oscillator. Reductions in photocurrent noise greater than 60% (−4 dB) below the limit set by the vacuum fluctuations of the field are observed in a balanced homodyne detector. A quantitative comparison with theory suggests that the observed noise reductions result from a field that in the absence of avoidable linear attenuation would be squeezed more than tenfold. A degree of squeezing of approximately fivefold is inferred for the actual field emitted through one mirror of the optical parametric oscillator. An explicit demonstration of the Heisenberg uncertainty principle for the electromagnetic field is made from the measurements, which show that the field state produced by the downconversion process is a state of minimum uncertainty.

Journal of the Optical Society of America B•Oct 1, 1987•338 citations

EXPERIMENTAL INVESTIGATION ABOUT TWO-MODE SQUEEZED STATE GENERATION OF LIGHT FIELD

Kunchi Peng, Maoquan Huang, LIU JING +6 more

Two-mode squeezed states of light field are experimentally generated by nondegenerate parametric down conversion in an optical cavity. Noise reductions of about 30% relative to the vacuum noise level are obtained in the quiet quadrature of the electromagnetic field.

Acta Physica Sinica•Jan 1, 1993•5 citations

Observation of Squeezed States Generated by Four-Wave Mixing in an Optical Cavity

R. E. Slusher, Leo W. Hollberg, Bernard Yurke +2 more

Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.

Physical Review Letters•Feb 17, 1986•31 citations

Observation of Squeezed States Generated by Four-Wave Mixing in an Optical Cavity

R. E. Slusher, Leo W. Hollberg, Bernard Yurke +2 more

Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.

Physical Review Letters•Nov 25, 1985•1,907 citations

Squeezed-state generation in optical bistability

Luis A. Orozco, Mark G. Raizen, Min Xiao +2 more

Experiments to generate squeezed states of light are described for a collection of two-level atoms within a high-finesse cavity. The investigation is conducted in a regime for which the weak-field coupling of atoms to the cavity mode produces a splitting in the normal mode structure of the atom–field system that is large compared with the atomic linewidth. Reductions in photocurrent noise of 30% (−1.55 dB) below the noise level set by the vacuum state of the field are observed in a balanced homodyne detector. A degree of squeezing of approximately 50% is inferred for the field state in the absence of propagation and detection losses. The observed spectrum of squeezing extends over a very broad range of frequencies (~±75 MHz), with the frequency of best squeezing corresponding to an offset from the optical carrier given by the normal mode splitting.

Journal of the Optical Society of America B•Oct 1, 1987•86 citations

Squeezed states of light

Harry J. Kimble

Squeezed states of the electromagnetic field are characterized by a reduction of fluctuations for one of two quadrature phase amplitudes below the level of fluctuations for the vacuum state. This reduction is a manifestly quantum or nonclassical feature which is of great interest in its own right but also potentially important for precision measurement with sensitivity beyond the shot-noise or vacuum-state limit. We describe three different experiments in which squeezed light has been generated in our laboratory involving parametric downconversion, intracavity frequency doubling, and optical bistability with two-state atoms. By employing the squeezed light produced by a subthreshold optical parametric oscillator, we have achieved improvements in sensitivity beyond the vacuum-state limit for the detection of both phase and amplitude changes of the electromagnetic field. An alternate route to sensitivity beyond the vacuum-state limit is through quantum nondemolition measurement, where we have suggested and are implementing a scheme involving parametric conversion and polarization mixing.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations
Squeezed states of the electromagnetic field are generated by degenerate parametric down conversion in an optical cavity. Noise reductions greater than 50% relative to the vacuum noise level are observed in a balanced homodyne detector. A quantitative comparison with theory suggests that the observed squeezing results from a field that in the absence of linear attenuation would be squeezed by greater then tenfold.
Squeezed states of the electromagnetic field are generated by degenerate parametric downconversion in a sub-threshold optical parametric oscillator. Reductions in photocurrent noise greater than 60% (−4 dB) below the limit set by the vacuum fluctuations of the field are observed in a balanced homodyne detector. A quantitative comparison with theory suggests that the observed noise reductions result from a field that in the absence of avoidable linear attenuation would be squeezed more than tenfold. A degree of squeezing of approximately fivefold is inferred for the actual field emitted through one mirror of the optical parametric oscillator. An explicit demonstration of the Heisenberg uncertainty principle for the electromagnetic field is made from the measurements, which show that the field state produced by the downconversion process is a state of minimum uncertainty.
Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.
Squeezed states of the electromagnetic field have been generated by nondegenerate four-wave mixing due to Na atoms in an optical cavity. The optical noise in the cavity, comprised of primarily vacuum fluctuations and a small component of spontaneous emission from the pumped Na atoms, is amplified in one quadrature of the optical field and deamplified in the other quadrature. These quadrature components are measured with a balanced homodyne detector. The total noise level in the deamplified quadrature drops below the vacuum noise level.
Experiments to generate squeezed states of light are described for a collection of two-level atoms within a high-finesse cavity. The investigation is conducted in a regime for which the weak-field coupling of atoms to the cavity mode produces a splitting in the normal mode structure of the atom–field system that is large compared with the atomic linewidth. Reductions in photocurrent noise of 30% (−1.55 dB) below the noise level set by the vacuum state of the field are observed in a balanced homodyne detector. A degree of squeezing of approximately 50% is inferred for the field state in the absence of propagation and detection losses. The observed spectrum of squeezing extends over a very broad range of frequencies (~±75 MHz), with the frequency of best squeezing corresponding to an offset from the optical carrier given by the normal mode splitting.
Squeezed states of the electromagnetic field are characterized by a reduction of fluctuations for one of two quadrature phase amplitudes below the level of fluctuations for the vacuum state. This reduction is a manifestly quantum or nonclassical feature which is of great interest in its own right but also potentially important for precision measurement with sensitivity beyond the shot-noise or vacuum-state limit. We describe three different experiments in which squeezed light has been generated in our laboratory involving parametric downconversion, intracavity frequency doubling, and optical bistability with two-state atoms. By employing the squeezed light produced by a subthreshold optical parametric oscillator, we have achieved improvements in sensitivity beyond the vacuum-state limit for the detection of both phase and amplitude changes of the electromagnetic field. An alternate route to sensitivity beyond the vacuum-state limit is through quantum nondemolition measurement, where we have suggested and are implementing a scheme involving parametric conversion and polarization mixing.