Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Optics Letters

High contrast transparent ramsey fringes using microwave pulses interaction with atomic coherent state in warm rubidium vapor

Yisheng Ma Yisheng, Jianliao Deng Jianliao Deng, Zhengfeng Hu Zhengfeng Hu, Huijuan He, Yuzhu Wang Yuzhu Wang

Published Jan 1, 2013• 1 citation
Publisher

Abstract

High contrast transparent Ramsey fringes are observed using double microwave pulses interaction with the prepared atomic coherent state in a warm 87 Rb vapor with mixture buffer gases in a closed cell.The Ramsey fringes are generated by the pulsed technique, a strong coupling light pulse and a weak signal light pulse are applied to prepare the atomic coherent state, followed by the application of double microwave pulses to interact with the atomic coherent state.Afterwards, the light pulses are applied again with weaker intensity and detecting the signal transmission is delected.The central line of the transparent Ramsey fringes has narrow linewidth of 125 Hz and high contrast of 21%.The light shift is dramatically reduced since the interrogating process is not involved the light field, and the cavity pulling effect is negligible due to the low Q requirement, which is promising for building small, compact, and stable atomic clocks.

DOI
10.3788/col201311.032701

Related papers

Raman–Ramsey pulsed excitation of coherent population trapping resonances in a 87Rb cell with a buffer gas

V. N. Baryshev, G. V. Osipenko, M. S. Aleinikov +1 more

We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D 1 lines of the 87 Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated.

Quantum Electronics•Mar 1, 2019•6 citations

High Contrast Ramsey Fringes with Coherent-Population-Trapping Pulses in a Double Lambda Atomic System

T. Zanon-Willette, Stéphane Guérandel, Emeric de Clercq +3 more

We report the observation of Raman-Ramsey fringes using a double lambda scheme creating coherent population trapping in an atomic ensemble combined with pulsed optical radiations. The observation was made in a Cs vapor mixed with N2 buffer gas in a closed cell. The double lambda scheme is created with lin perpendicular lin polarized laser beams leading to higher contrast than the usual simple lambda scheme. The pulsed trapping technique leads to narrow fringe widths scaling as 1/(2T) with high contrasts which are no longer limited by the saturation effect. This technique operates in a different way from the classical Ramsey sequence: the signal is done by applying a long trapping pulse to prepare the atomic state superposition, and fringe detection is accomplished by optical transmission during a short second trapping pulse without any perturbation of the dark state.

Physical Review Letters•May 17, 2005•268 citations

Ramsey-fringe shape in an alkali-metal vapor cell with buffer gas

Salvatore Micalizio, Claudio Eligio Calosso, Filippo Levi +1 more

In this paper we describe a few phenomena that may affect the linewidth and/or the line shape of Ramsey fringes observed in an alkali-metal vapor cell with buffer gas. Experiments are performed on a vapor-cell--microwave-cavity arrangement in which ${}^{87}\mathrm{Rb}$ atoms successively experience laser pumping preparation (through a ${D}_{2}$ line), microwave interrogation with a couple of coherent pulses, and clock signal detection by means of laser absorption. We show that the linewidth of the Ramsey central fringe is influenced by the Rabi pattern produced by a single microwave pulse. Moreover, cycle memory and atomic density effects can modify the shape of the Ramsey central fringe from the common sinusoidal behavior. A simple three-level model well reproduces the experimental observations.

Physical Review A•Sep 3, 2013•14 citations

Optical Ramsey interference and its performance in D1 line excitation in rubidium vapor for implementation of a vapor cell clock

G. S. Pati, Fredrik K. Fatemi, Mark Bashkansky +1 more

Pulsed coherent population trapping in atomic vapor provides a convenient method for generating frequency narrowed atomic resonance using Ramsey interference. Here, we present our experimental results showing high-contrast and sub-kilohertz Ramsey interference fringes produced by coherently prepared 85Rb atoms using Raman excitation formed in D1 line transitions. A test system for atomic clock has been constructed to measure light shift for both continuous and pulsed Raman excitation cases. Our measurements show that light shift measured using pulsed Raman excitation, is reduced compared to the continuous excitation case. Our ability to measure light shift is currently limited by the resolution of the frequency counter, and performance of the locking electronics used.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Feb 10, 2011•6 citations

Formation of Ramsey fringes based on pulsed coherent light storage

Bo Yan, Yisheng Ma, Yuzhu Wang

We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low $Q$ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.

arXiv:0810.0623•Physical Review A•Jun 11, 2009•6 citations

Study of Pulsed Optically Pumped Rb Frequency Standard

Shougang Zhang

The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.

Wuhan Daxue xuebao. Xinxi kexue ban•Jan 1, 2011•0 citations
High contrast transparent Ramsey fringes are observed using double microwave pulses interaction with the prepared atomic coherent state in a warm 87 Rb vapor with mixture buffer gases in a closed cell.The Ramsey fringes are generated by the pulsed technique, a strong coupling light pulse and a weak signal light pulse are applied to prepare the atomic coherent state, followed by the application of double microwave pulses to interact with the atomic coherent state.Afterwards, the light pulses are applied again with weaker intensity and detecting the signal transmission is delected.The central line of the transparent Ramsey fringes has narrow linewidth of 125 Hz and high contrast of 21%.The light shift is dramatically reduced since the interrogating process is not involved the light field, and the cavity pulling effect is negligible due to the low Q requirement, which is promising for building small, compact, and stable atomic clocks.
We report the results of experimental investigation of the Raman – Ramsey method of pulsed excitation of coherent population trapping (CPT) resonances in a rubidium vapour cell filled with a mixture of Ar and Ne buffer gases. For the development of compact quantum microwave frequency standards, this method is an alternative to the pulsed optical pumping method recently implemented using the same rubidium cell. Both methods have advantages over the traditional double radio-optical resonance technique, the main of which is the substantial suppression of the light shift of the clock transition frequency, since the evolution of the coherence of atomic states forming the clock transition occurs in the absence of laser radiation in the cell. The narrow (110 – 240 Hz) Raman – Ramsey resonances are obtained using the scheme of pulsed excitation of CPT resonances on the D 1 lines of the 87 Rb atom with the same linear (lin||lin) polarisations of the bichromatic laser radiation components. The process of optimising the central fringe linewidth, its contrast, and the linewidth-to-contrast ratio is described. The magnetic dependence of the Raman – Ramsey line central fringe linewidth is experimentally investigated.
We report the observation of Raman-Ramsey fringes using a double lambda scheme creating coherent population trapping in an atomic ensemble combined with pulsed optical radiations. The observation was made in a Cs vapor mixed with N2 buffer gas in a closed cell. The double lambda scheme is created with lin perpendicular lin polarized laser beams leading to higher contrast than the usual simple lambda scheme. The pulsed trapping technique leads to narrow fringe widths scaling as 1/(2T) with high contrasts which are no longer limited by the saturation effect. This technique operates in a different way from the classical Ramsey sequence: the signal is done by applying a long trapping pulse to prepare the atomic state superposition, and fringe detection is accomplished by optical transmission during a short second trapping pulse without any perturbation of the dark state.
In this paper we describe a few phenomena that may affect the linewidth and/or the line shape of Ramsey fringes observed in an alkali-metal vapor cell with buffer gas. Experiments are performed on a vapor-cell--microwave-cavity arrangement in which 87Rb{}^{87}\mathrm{Rb}87Rb atoms successively experience laser pumping preparation (through a D2{D}_{2}D2​ line), microwave interrogation with a couple of coherent pulses, and clock signal detection by means of laser absorption. We show that the linewidth of the Ramsey central fringe is influenced by the Rabi pattern produced by a single microwave pulse. Moreover, cycle memory and atomic density effects can modify the shape of the Ramsey central fringe from the common sinusoidal behavior. A simple three-level model well reproduces the experimental observations.
Pulsed coherent population trapping in atomic vapor provides a convenient method for generating frequency narrowed atomic resonance using Ramsey interference. Here, we present our experimental results showing high-contrast and sub-kilohertz Ramsey interference fringes produced by coherently prepared 85Rb atoms using Raman excitation formed in D1 line transitions. A test system for atomic clock has been constructed to measure light shift for both continuous and pulsed Raman excitation cases. Our measurements show that light shift measured using pulsed Raman excitation, is reduced compared to the continuous excitation case. Our ability to measure light shift is currently limited by the resolution of the frequency counter, and performance of the locking electronics used.
We propose a scheme of obtaining Ramsey fringes based on pulsed coherent optical information storage. Unlike the usual frequency references where the Ramsey fringes are obtained by detecting the population of a certain state, we get the Ramsey fringes by detecting the atomic coherence. The central line of the Ramsey fringes can be used as a frequency reference in an absorption-cell-based atomic frequency standard. This scheme is free of light shifts as the interrogating process is separated from the optical pumping process, and the cavity pulling effect is negligible due to the low QQQ requirement. Encoding the Ramsey interference into the retrieval light pulse has the merit of high signal-to-noise ratio. This scheme is promising for building small, compact, and stable atomic clocks.
The pulsed optically pumped(POP) 87Rb vapor-cell frequency standard was studied based on the detection of free induction microwave signal or optical absorption signal.In POP operation the pumping,interrogation,and detection phases are separated in time,avoiding the coupling between microwave and optical coherence.The theoretical results show that an oscillation period doubled with respect to the classical Ramsey method which leads to a doubled atomic quality factor Q,and the reduction of optical shift and cavity pulling shift will be obtained,when the atoms are submitted to π/2 Ramsey microwave pulse.In experiment Ramsey fringes were obtained with a clock prototype based on 87Rb in buffer gas,with bandwidth of 65 Hz and 150 Hz for microwave and optical signal respectively.The frequency stability achieved was 1.2×10-12 for measurement times up to 100 s.