Low-pressure source of slow metastable rare gas atoms
M. H. L. van der Velden, Herman Batelaan, Edwin te Sligte +2 more
We investigate the properties of a commercial inverted magnetron pressure gauge for use as a source of slow metastable rare gas atoms. We find that the velocity distribution of the atoms as well as the pressure dependence of the output flux agree with a simple model. This shows that the low-velocity output of the source is enhanced over the Maxwell–Boltzmann form due to a velocity-dependent excitation probability. For argon, the center-line intensity per unit area of the source is measured to be greater than 4.2×1015 Ar 1s5 atoms/(s sr m2) at a pressure of 23 mPa. When observing the entire source area, the center-line intensity is at least 2.6×1011 Ar 1s5 atoms/(s sr).
Review of Scientific Instruments•Mar 20, 2004•1 citation