Review of Scientific Instruments
Low-pressure source of slow metastable rare gas atoms
M. H. L. van der Velden, Herman Batelaan, Edwin te Sligte, Herman C. W. Beijerinck, Edgar J. D. Vredenbregt
Abstract
We investigate the properties of a commercial inverted magnetron pressure gauge for use as a source of slow metastable rare gas atoms. We find that the velocity distribution of the atoms as well as the pressure dependence of the output flux agree with a simple model. This shows that the low-velocity output of the source is enhanced over the Maxwell–Boltzmann form due to a velocity-dependent excitation probability. For argon, the center-line intensity per unit area of the source is measured to be greater than 4.2×1015 Ar 1s5 atoms/(s sr m2) at a pressure of 23 mPa. When observing the entire source area, the center-line intensity is at least 2.6×1011 Ar 1s5 atoms/(s sr).