We present a design for a spin-exchange optical pumping system to produce large quantities of highly polarized 129Xe and 131Xe. Low xenon concentrations in the flowing gas mixture which allow the laser to maintain high Cs polarization. The large spin-exchange rate between Cs and Xe through the long-lived van der Waals molecules at low pressure, combined with a high flow rate, results in large production rates of hyperpolarized xenon. The fast rates make it possible to obtain large nuclear polarizations after several minutes of optical pumping with a laser.At high Xe pressures. According to the theory, the longitudinal spin-elaxation rate 1T1 of Xe in a high-pressure sample containing only Xe and Cs vapor has the simple form is the velocity averaged binary spin-exchange cross section, It is the relaxation rate due to wall collisions and perhaps magnetic field inhomogeneities. Our results complement earlier studies performed at 129Xe pressures of about 20 Torr and 131Xe pressures of about 20 Torr and N2 pressures of 600 Torr . This work is useful for predicting spin-exchange rates between polarized Cs atoms and Xe nuclei.
We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.
Here we present a $\mathrm{Rb}\text{\ensuremath{-}}^{129}\mathrm{Xe}$ spin-exchange optical pumping polarizer capable of rapid generation of large volumes of highly polarized
129Xe gas. Through modeling and measurements we maximize the
129Xe nuclear spin polarization output to enable the generation of polarized
129Xe gas imaging volumes (
300 cm3) every 5 min within a clinical setting. Our model is verified by experiment to correctly predict the optimum Rb vapor density for maximum
129Xe nuclear polarization for a flux
3.4 W/cm2 of circularly polarized Rb
D1 photons incident on an 80 cm long cylindrical optical cell. We measure a
129Xe magnetization production efficiency of ${\ensuremath{\eta}}_{\mathrm{pr}}=1.8%$, which approaches the photon efficiency limit ${\ensuremath{\eta}}_{\ensuremath{\gamma}}=3.3%$ of this system and enables the polarization of $2.72\ifmmode\times\else\texttimes\fi{}{10}^{22}$
129Xe spins per hour, corresponding to
1013 cm3 of 100% polarized
129Xe at STP. This magnetization production rate is threefold higher than the highest previously published
129Xe magnetization production rate and has enabled routine clinical lung magnetic resonance imaging (MRI) with hyperpolarized
129Xe doses available on demand at run time, as well as high-SNR
129Xe MRI of the human brain and kidneys.
Spin-exchange collisions between polarized 87 Rb atoms and unpolarized 129 Xe nuclei have been used to produce nuclear spin polarized 129 Xe. Measurements of the longitudinal relaxation rate of 129 Xe nuclear polarization have been carried out in a 5.7G magnetic field. The present results show that the nuclear spin relaxation rate of 129 Xe in 87 Rb vapor is proportional to the density of the 87 Rb atoms, and the nuclear spin relaxation rates of 129 Xe induced by the 87 Rb atoms depend on the pressure of the buffer gas N 2 .
We analyze the transverse nuclear magnetizations of 129Xe and 131Xe in a vapor cell containing natural Xe, 87Rb, and buffer gases. The Xe atoms are polarized through spin-exchange optical pumping (SEOP) with Rb atoms under low-magnetic-field conditions. From the free-induction-decay (FID) signal, we measure the nuclear magnetization of the Xe atoms in the Xe-Rb vapor cell. Furthermore, we measure the dependence of the gyromagnetic ratio on the magnetization of 129Xe and 131Xe by examining the amplitude of the FID signal of each isotope, and we evaluate the relationship between the magnetic field gradient and transverse relaxation rate for both of the 129Xe and 131Xe isotopes.
We present a design for a spin-exchange optical pumping system to produce large quantities of highly polarized 129Xe. Low xenon concentrations in the flowing gas mixture allow the laser to maintain high Rb polarization. The large spin-exchange rate between Rb and 129Xe through the long-lived van der Waals molecules at low pressure, combined with a high flow rate, results in large production rates of hyperpolarized xenon. We report a maximum polarization of 64% achieved for a 0.3 l/h Xe flow rate, and maximum magnetization output of 6 l/h at 22% polarization. Our findings regarding the polarization dependence on temperature, nitrogen partial pressure, and gas mixture flow velocity are also reported.