Study of the vapor cell size at high sensitive Cs magnetometer

Jiuxing Li, Qiang Liu, Qingmeng Li, Junhai Zhang, Weimin Sun

Published Nov 23, 2011• 0 citations
Publisher

Abstract

The spin-exchange relaxation free (SERF) magnetometers are the most sensitive atomic magnetometers, the optimum sensitivity of which is on the order of 0.1 fTHz-1/2. The size of the vapor cell is important in the miniaturization of the Cs vapor magnetometer, for it determining other components'. The more importance is dependence of the spin-destruction rate, which is the maximum relaxation rate in the SERF regime. This paper presents the design of the vapor cell at Cs SERF magnetometers and the discussion of the highest sensitivity achieved in different sizes.

DOI
10.1117/12.904724

Related papers

Study of resonance curve width in Cs vapor magnetometer

Sun Weimin

A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.

Journal of Optoelectronics·laser•Jan 1, 2010•0 citations

Spin-exchange-relaxation-free magnetometry with Cs vapor

M. P. Ledbetter, Igor Savukov, Víctor M. Acosta +2 more

We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

arXiv:0708.1012•Physical Review A•Mar 13, 2008•400 citations

Study of optimum pumping intensity at Cs vapor magnetometer

Junhai Zhang, Feng Wang, Jiuxing Li +1 more

The paper describes a new magnetometer with Cs vapor in the spin exchange relaxation free (SERF) regime. Because cesium atom has a higher saturated vapor pressure than other alkali metallic atoms, so the magnetometer has required lower operated temperature. We have discussed the effect of different pumping intensities on the polarization and the pumping rate at 105°C in theory; and the result shows out the magnetometer will have maximum sensitivity when the pumping intensity is 52mW/cm2. Taking into account all relaxations including collision relaxations, diffusion relaxation and pumping relaxation from pump light, we find the relaxation rate will be about 6Hz for the cesium magnetometer with SERF.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 13, 2010•1 citation

Measurement of Relaxation Mechanism for the Spin-Exchange Relaxation-Free Magnetometer

Jin Peng, An‐Ning Xu, Yiran Yin +1 more

The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.

IEEE Sensors Journal•Dec 7, 2023•11 citations

Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell

Yibo Qi, Bo Li, Shuying Wang +3 more

Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz$^{1/2}$) was 1.89 times that of the single-pass configuration (3.4 fT/Hz$^{1/2}$), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2024•18 citations

The Characterization of Atomic Vapor Cells for High-Sensitivity Magnetic Field Measurements in SERF Regime

Murat Salim Karabinaoğlu, Berfin Muhlise Caklı, Mehmet Hüseyin Sevim

Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.

IEEE Sensors Letters•Feb 24, 2025•5 citations
The spin-exchange relaxation free (SERF) magnetometers are the most sensitive atomic magnetometers, the optimum sensitivity of which is on the order of 0.1 fTHz-1/2. The size of the vapor cell is important in the miniaturization of the Cs vapor magnetometer, for it determining other components'. The more importance is dependence of the spin-destruction rate, which is the maximum relaxation rate in the SERF regime. This paper presents the design of the vapor cell at Cs SERF magnetometers and the discussion of the highest sensitivity achieved in different sizes.
A new magnetometer with Cs vapor in the spin exchange relaxation free(SERF) regime is described.Cs has a higher saturated vapor pressure than other alkali metals;so cesium SERF magnetometer is particularly attractive in applications that require lower power dissipation.Four factors affect atomic transverse relaxations in the SERF magnetometer,including collisions and diffusions among Cs,N2 and He,laser pumping and detecting processes;the buffer gas pressure of He that affects the relaxation is calculated and discussed emphatically in theory at 105 ℃,the result shows that the optimum buffer gas pressure is 350×133.3 Pa.Under the optimum pressure,the polarized spectrum linewidth as the function of the cell temperature is discussed briefly.It is found the least linewidth is only 3.7 Hz corresponding to the electric spin relaxation rate of 278 s-1 at 105 ℃.The result provides a help to increase the sensitivity of the magnetometer with Cs vapor.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400 pG/Hz400\text{ }\text{pG}/\sqrt{\text{Hz}}400 pG/Hz​. Based on photon shot noise, we project a sensitivity of 40 pG/Hz40\text{ }\text{pG}/\sqrt{\text{Hz}}40 pG/Hz​. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2 pG/Hz2\text{ }\text{pG}/\sqrt{\text{Hz}}2 pG/Hz​ should be achievable in a 1 cm31\text{ }{\text{cm}}^{3}1 cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.
The paper describes a new magnetometer with Cs vapor in the spin exchange relaxation free (SERF) regime. Because cesium atom has a higher saturated vapor pressure than other alkali metallic atoms, so the magnetometer has required lower operated temperature. We have discussed the effect of different pumping intensities on the polarization and the pumping rate at 105°C in theory; and the result shows out the magnetometer will have maximum sensitivity when the pumping intensity is 52mW/cm2. Taking into account all relaxations including collision relaxations, diffusion relaxation and pumping relaxation from pump light, we find the relaxation rate will be about 6Hz for the cesium magnetometer with SERF.
The spin-exchange relaxation-free (SERF) atomic magnetometer (AM) has vital importance in advanced research and has been widely applied in different fields. To improve the sensitivity and robustness of SERF magnetometers, understanding the relaxation mechanism is a significant approach. By controlling the amplitude and direction of external magnetic fields, and switching statuses of the pump and probe laser beam, we measured both the transverse and longitudinal relaxation rate in two experimental methods, respectively, and obtained the Larmor precession frequency, the spin-exchange relaxation rate, the spin-destruction relaxation rate, and the relaxation rate due to collisions between atoms and vapor cell walls. All experimental results are verified with the theoretical calculations. The final longitudinal relaxation rate of our magnetometer is 53 Hz. Furthermore, we measured the sensitivity of our SERF magnetometer reaching 5 fT/Hz1/2 from 5 to 70 Hz after differential measurement with the 3-dB bandwidth of 70 Hz. Our work helps to improve the detection capability of SERF magnetometers, providing performance assurance for searching for exotic spin-dependent interactions and applications, including magnetoencephalograms and magnetocardiograms.
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz1/2^{1/2}1/2) was 1.89 times that of the single-pass configuration (3.4 fT/Hz1/2^{1/2}1/2), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
Nowadays, quantum sensor research is a very interesting and popular topic. High-sensitivity magnetic field measurements using quantum sensors have evolved into the most sensitive magnetic field sensor category today with the invention of atomic magnetometers operating in the spin-exchange relaxation-free (SERF) regime. This letter was prepared to investigate the magnetic field sensitivity changes depending on the buffer gas, temperature, and laser intensity using indigenously produced atomic vapor cells. In addition, the aim was to determine the optimum operating conditions of the atomic magnetometer operating in the SERF regime. As a result, the resonance linewidth and signal-to-noise ratio were measured, and the minimum detectable magnetic field was calculated. According to the obtained results, the lowest magnetic field for Cells I–III was measured as 5.12, 4.21, and 4.81 pT, respectively. The lowest magnetic field of all conditions was obtained in vapor cell (Cell-II) at 100 °C with 5 mW laser intensity. As a result, it has been experimentally proven that under the same conditions, increasing the buffer gas pressure in vapor cells can narrow the resonance linewidth, and the magnetic field sensitivity can be improved by increasing the laser intensity applied to the vapor cells.