Europhysics Letters (EPL)

Picotesla magnetometry with coherent dark states

Markus Stähler, Svenja A. Knappe, C. Affolderbach, W Kemp, R. Wynands

Published May 1, 2001• 109 citations
Publisher

Abstract

We investigate the experimental sensitivity limit of a scalar optical magnetometer based on coherent population trapping on the D 2 line of a thermal cesium vapor. We find the expected strong dependence on averaging time, with a detection limit below 4 pT for integration times longer than 1 s, limited by slow drifts of the cell temperature and of the applied test magnetic-field itself. A detailed noise analysis shows that for shorter averaging times the demonstrated limit of about 12 pT/√Hz is dominated by the frequency noise of the laser source. The magnetometer can be operated for real-time detection in flux densities up to at least milliteslas and is robust enough for application outside the laser laboratory.

DOI
10.1209/epl/i2001-00245-y

Related papers

Experimental realization of coherent dark-state magnetometers

A. Nagel, L Graf, A Naumov +4 more

Coherent population trapping resonances in cesium vapor can be used to determine DC flux densities in the range from 1 mu T to 1 mT with typically 3.10(-5) relative uncertainty. For fields modulated at a few kHz, we find sensitivities of below 10 pT within 0.5 s integration time. From the signal-to-noise ratio the sensitivity can be extrapolated to 500 fT/root Hz.. A quantitative understanding of the lineshape allows to detect DC fields of several nT even when the Zeeman components of the resonance are not resolved.

Europhysics Letters (EPL)•Oct 1, 1998•124 citations

Miniaturized laser magnetometers and clocks

R. Wynands, C. Affolderbach, Leo W. Hollberg +3 more

We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision applications like magnetometry or atomic frequency standards, using the D lines in thermal Cs or Rb vapor. The magnetometer operates by monitoring the position of the Zeeman-shifted outermost resonance component. The central Zeeman component is well suited for frequency standard applications because its position is shifted by magnetic fields only in second order. We derive the required pair of laser fields form a special diode laser by direct modulation of the injection current. Magneto metric sensitivity down to a picotesla and 10-12 relative instability for a finger-sized clock have been achieved in this way. Use of a magnetic gradiometer allows to cancel fluctuations of ambient magnetic fields to a large degree, making possible sensitive measurements even outside magnetically shielded rooms.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 3, 2002•1 citation

Remotely-sensed atomic magnetometry

Christopher J. Sataline

Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.

•Jan 1, 2013•0 citations

Magnetometry and frequency references with coherent dark states

Sebastián Brandt, A. Nagel, Oliver G. Schmidt +2 more

Summary form only given, as follows.The 30 kHz linewidth and extremely steep dispersion of a coherent dark resonance in a caesium vapor cell allows measurements of magnetic fields to about 10 nT in 0.1 s integration time, limited by stray fields. The narrow resonance should make possible a compact frequency standard. In a preliminary experiment the authors used a coherent dark resonance in a 2 cm long caesium vapor cell to measure magnetic fields with about 10-5 uncertainty. Two diode lasers (852 nm wavelength) were phase-locked onto each other with a 9.2 GHz frequency offset, corresponding to the frequency ground state separation of the two caesium levels. The difference frequency is derived from a stable tunable rf source. Absorption spectrum of the caesium coherent population trapping resonance for linear laser polarizations is illustrated; it is split into seven components by a magnetic field parallel to the laser polarization direction. The width of the individual lines is only 130 kHz due to power broadening. The steep slope of the resonance could be used to lock the frequency of the 9.2 GHz rf source. This would provide a compact frequency reference.

Conference on Precision Electromagnetic Measurements•Dec 24, 2002•0 citations

A high-sensitivity push-pull magnetometer

E. Breschi, Z. D. Grujić, P. Knowles +1 more

We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/Hz, using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/Hz.

arXiv:1312.3567•Applied Physics Letters•Jan 13, 2014•40 citations

High-temperature lithium atomic magnetometry by symmetric hyperfine coherent population trapping resonances

Kiyoshi Ishikawa

A glass lithium vapor cell is an atomic sensor operating at high temperature. The longitudinal magnetic-field strength is measured by coherent population trapping (CPT) in ground-state hyperfine levels. Two linearly polarized light beams are polarized orthogonally to each other. The difference of optical frequencies is tuned to generate a dark state. Additionally, a few light modes of equidistant frequency spacing are generated by modulating the difference frequency. The symmetry of the light modes and the energy levels enables simultaneous measurement of the hyperfine splitting frequency of the ground state and the magnetic-field strength. Tuning the optical frequency difference to the central CPT resonance, a sensitivity of 15 p T / H z is achieved. The time response and the sensitivity of the CPT magnetometry are studied by changing the cell temperature, the laser power, the frequency separation of the light modes, and the Zeeman frequency.

Journal of the Optical Society of America B•Jun 24, 2021•4 citations
We investigate the experimental sensitivity limit of a scalar optical magnetometer based on coherent population trapping on the D 2 line of a thermal cesium vapor. We find the expected strong dependence on averaging time, with a detection limit below 4 pT for integration times longer than 1 s, limited by slow drifts of the cell temperature and of the applied test magnetic-field itself. A detailed noise analysis shows that for shorter averaging times the demonstrated limit of about 12 pT/√Hz is dominated by the frequency noise of the laser source. The magnetometer can be operated for real-time detection in flux densities up to at least milliteslas and is robust enough for application outside the laser laboratory.
Coherent population trapping resonances in cesium vapor can be used to determine DC flux densities in the range from 1 mu T to 1 mT with typically 3.10(-5) relative uncertainty. For fields modulated at a few kHz, we find sensitivities of below 10 pT within 0.5 s integration time. From the signal-to-noise ratio the sensitivity can be extrapolated to 500 fT/root Hz.. A quantitative understanding of the lineshape allows to detect DC fields of several nT even when the Zeeman components of the resonance are not resolved.
We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision applications like magnetometry or atomic frequency standards, using the D lines in thermal Cs or Rb vapor. The magnetometer operates by monitoring the position of the Zeeman-shifted outermost resonance component. The central Zeeman component is well suited for frequency standard applications because its position is shifted by magnetic fields only in second order. We derive the required pair of laser fields form a special diode laser by direct modulation of the injection current. Magneto metric sensitivity down to a picotesla and 10-12 relative instability for a finger-sized clock have been achieved in this way. Use of a magnetic gradiometer allows to cancel fluctuations of ambient magnetic fields to a large degree, making possible sensitive measurements even outside magnetically shielded rooms.
Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.
Summary form only given, as follows.The 30 kHz linewidth and extremely steep dispersion of a coherent dark resonance in a caesium vapor cell allows measurements of magnetic fields to about 10 nT in 0.1 s integration time, limited by stray fields. The narrow resonance should make possible a compact frequency standard. In a preliminary experiment the authors used a coherent dark resonance in a 2 cm long caesium vapor cell to measure magnetic fields with about 10-5 uncertainty. Two diode lasers (852 nm wavelength) were phase-locked onto each other with a 9.2 GHz frequency offset, corresponding to the frequency ground state separation of the two caesium levels. The difference frequency is derived from a stable tunable rf source. Absorption spectrum of the caesium coherent population trapping resonance for linear laser polarizations is illustrated; it is split into seven components by a magnetic field parallel to the laser polarization direction. The width of the individual lines is only 130 kHz due to power broadening. The steep slope of the resonance could be used to lock the frequency of the 9.2 GHz rf source. This would provide a compact frequency reference.
We describe our approach to atomic magnetometry based on the push-pull optical pumping technique. Cesium vapor is pumped and probed by a resonant laser beam whose circular polarization is modulated synchronously with the spin evolution dynamics induced by a static magnetic field. The magnetometer is operated in a phase-locked loop, and it has an intrinsic sensitivity below 20fT/Hz, using a room temperature paraffin-coated cell. We use the magnetometer to monitor magnetic field fluctuations with a sensitivity of 300fT/Hz.
A glass lithium vapor cell is an atomic sensor operating at high temperature. The longitudinal magnetic-field strength is measured by coherent population trapping (CPT) in ground-state hyperfine levels. Two linearly polarized light beams are polarized orthogonally to each other. The difference of optical frequencies is tuned to generate a dark state. Additionally, a few light modes of equidistant frequency spacing are generated by modulating the difference frequency. The symmetry of the light modes and the energy levels enables simultaneous measurement of the hyperfine splitting frequency of the ground state and the magnetic-field strength. Tuning the optical frequency difference to the central CPT resonance, a sensitivity of 15 p T / H z is achieved. The time response and the sensitivity of the CPT magnetometry are studied by changing the cell temperature, the laser power, the frequency separation of the light modes, and the Zeeman frequency.