Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Miniaturized laser magnetometers and clocks

R. Wynands, C. Affolderbach, Leo W. Hollberg, John E. Kitching, Svenja A. Knappe, Michael D. Staehler

Published Apr 3, 2002• 1 citation
Publisher

Abstract

We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision applications like magnetometry or atomic frequency standards, using the D lines in thermal Cs or Rb vapor. The magnetometer operates by monitoring the position of the Zeeman-shifted outermost resonance component. The central Zeeman component is well suited for frequency standard applications because its position is shifted by magnetic fields only in second order. We derive the required pair of laser fields form a special diode laser by direct modulation of the injection current. Magneto metric sensitivity down to a picotesla and 10-12 relative instability for a finger-sized clock have been achieved in this way. Use of a magnetic gradiometer allows to cancel fluctuations of ambient magnetic fields to a large degree, making possible sensitive measurements even outside magnetically shielded rooms.

DOI
10.1117/12.464463

Related papers

VCSELs in nonlinear spectroscopy: making optical magnetometers and atomic clocks practical

R. Wynands, C. Affolderbach, Leo W. Hollberg +3 more

We have experimentally investigated the potential af narrow coherent population trapping (CPT) resonances for precision applications like magnetometry, miniaturised atomic frequency standards and the determination of atomic g-factors using the D lines in thermal Cs or Rb vapour.

IEEE/LEOS Summer Topical Meetings•Nov 13, 2002•0 citations

Magnetometer and frequency standard based on coherently prepared thermal alkali atomic vapors

C. Affolderbach, W R G Kemp, Svenja A. Knappe +3 more

Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping resonances for precision applications like magnetometry or atomic frequency standards. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. Effective formation of ground state coherences takes place when the frequency difference of the light fields precisely matches the ground state splitting. This process leads to reduced absorption in the medium (electromagnetically induced transparency) and thus reduced fluorescence intensity (dark resonance) at the optical resonance frequency. Extremely narrow dark resonances can be observed when the two light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications. The /spl Lambda/ systems under study here are the D/sub 2/ lines of Cs, /sup 87/Rb and /sup 85/Rb where the ground state hyperfine splittings are 9.2 GHz, 6.8 GHz, and 3.0 GHz, respectively. Thus in a magnetic field the CPT resonance splits into several Zeeman components whose frequency positions are determined by the Breit-Rabi formula.

Quantum Electronics and Laser Science Conference•May 7, 2000•1 citation

All optical automated magnetic field monitoring based on coherent population trapping produced by a frequency-modulated diode laser

Jacopo Belfi, G. Bevilacqua, V. Biancalana +2 more

A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2007•0 citations

Picotesla magnetometer based on coherently prepared thermal alkali atomic vapors

C. Affolderbach, W. Kemp, Svenja A. Knappe +2 more

Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision magnetometry. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. On resonance, effective formation of long-lived ground state coherences which do not couple in the light fields leads to reduced absorption in the medium ("electromagnetically induced transparency") and thus reduced fluorescence intensity ("dark resonance"). Extremely narrow CPT resonances can be observed when the light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications.

Conference on Lasers and Electro-Optics•Aug 29, 2005•0 citations

All optical sensor for automated magnetometry based on coherent population trapping

Jacopo Belfi, G. Bevilacqua, V. Biancalana +2 more

An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.

arXiv:0705.1671•Journal of the Optical Society of America B•Jun 15, 2007•38 citations

Cold-atom double- Λ coherent population trapping clock

François-Xavier Esnault, E. Blanshan, Eugene N. Ivanov +3 more

Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on ${}^{87}$Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.

Physical Review A•Oct 31, 2013•83 citations
We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision applications like magnetometry or atomic frequency standards, using the D lines in thermal Cs or Rb vapor. The magnetometer operates by monitoring the position of the Zeeman-shifted outermost resonance component. The central Zeeman component is well suited for frequency standard applications because its position is shifted by magnetic fields only in second order. We derive the required pair of laser fields form a special diode laser by direct modulation of the injection current. Magneto metric sensitivity down to a picotesla and 10-12 relative instability for a finger-sized clock have been achieved in this way. Use of a magnetic gradiometer allows to cancel fluctuations of ambient magnetic fields to a large degree, making possible sensitive measurements even outside magnetically shielded rooms.
Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping resonances for precision applications like magnetometry or atomic frequency standards. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. Effective formation of ground state coherences takes place when the frequency difference of the light fields precisely matches the ground state splitting. This process leads to reduced absorption in the medium (electromagnetically induced transparency) and thus reduced fluorescence intensity (dark resonance) at the optical resonance frequency. Extremely narrow dark resonances can be observed when the two light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications. The /spl Lambda/ systems under study here are the D/sub 2/ lines of Cs, /sup 87/Rb and /sup 85/Rb where the ground state hyperfine splittings are 9.2 GHz, 6.8 GHz, and 3.0 GHz, respectively. Thus in a magnetic field the CPT resonance splits into several Zeeman components whose frequency positions are determined by the Breit-Rabi formula.
A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.
Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision magnetometry. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. On resonance, effective formation of long-lived ground state coherences which do not couple in the light fields leads to reduced absorption in the medium ("electromagnetically induced transparency") and thus reduced fluorescence intensity ("dark resonance"). Extremely narrow CPT resonances can be observed when the light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications.
An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.
Miniature atomic clocks based on coherent population trapping (CPT) states in thermal atoms are an important component in many field applications, particularly where satellite frequency standards are not accessible. Cold-atom CPT clocks promise improved accuracy and stability over existing commercial technologies. Here we demonstrate a cold-atom CPT clock based on 87{}^{87}87Rb using a high-contrast double-$\ensuremath{\Lambda}$ configuration. Doppler frequency shifts are explained using a simple model and canceled by interrogating the atoms with counterpropagating light beams. We realize a compact cold-atom CPT clock with a fractional frequency stability of $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}11}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, thus demonstrating the potential of these devices. We also show that the long-term stability is currently limited by the second-order Zeeman shift to $2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}12}$ at 1000 s.