Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Experimental and Theoretical Physics Letters

Generalized ramsey scheme for precision spectroscopy of ultracold atoms and ions: Inclusion of a finite laser line width and spontaneous relaxation of the atomic levels

K. S. Tabatchikova, А. В. Тайченачев, Valeriy I. Yudin

Published May 1, 2013• 11 citations
Publisher

Abstract

Ramsey schemes with pulses of different lengths and with a composite pulse have been analyzed taking into account a finite width of the laser line and spontaneous relaxation of atomic levels. The optimal parameters of pulses corresponding to the maximum suppression of the excitation-related shift and the maximum resonance amplitude have been found for both schemes. According to the numerical results, spontaneous relaxation of the atomic levels and a finite width of the laser line must be taken into account in the calculation of the optimal parameters of the excitation pulses. The Ramsey scheme with a composite pulse is less sensitive to fluctuations of the Rabi frequency than the scheme with pulses of different lengths.

DOI
10.1134/s0021364013060155

Related papers

Study of field shifts of Ramsey resonances on ultracold atoms and ions

K. S. Tabatchikova, A. V. Taǐchenachev, А. К. Дмитриев +1 more

The effect of the finite laser radiation line width and spontaneous relaxation of levels on the efficiency of the suppression of the field shift of the central resonance for the generalized Ramsey scheme with pulses of different lengths and with a phase jump in the second pulse has been considered. The optimal parameters of the scheme corresponding to the minimum frequency shift and maximum amplitude of the resonance have been determined.

Journal of Experimental and Theoretical Physics•Feb 1, 2015•8 citations

Suppression of the Field Shift of Ramsey Resonance on Forbidden Transitions of Atoms and Ions

K. S. Tabatchikova, А. В. Тайченачев, Valeriy I. Yudin

We perform a theoretical analysis of the Ramsey scheme with pulses of different duration and with a phase step in the second pulse with account for the finite width of laser line. We define optimum features of pulses that correspond to maximum suppression of the field shift and maximum amplitude of resonance for both schemes. Ramsey scheme with a phase step in the second pulse provides effective suppression of the field shift and it is less sensitive to the Rabi frequency fluctuations in comparison with Ramsey scheme with pulses of different duration. First experiments on ytterbium single-ion optical clock (Germany, PTB) confirm theoretical predictions

Siberian Journal of Physics•Oct 1, 2012•0 citations

Generalized Hyper-Ramsey spectroscopy in an optically dense medium

К. А. Баранцев, T. Zanon-Willette, Litvinov, A. N.

In this work, the peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. We considered different composite pulse protocols for clock spectroscopy such as hyper-Ramsey, modified and generalized hyper-Ramsey schemes. Shapes of resonances and error signals changes significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is theoretically studied when taking into account the attenuation of the radiation intensity in the medium. The change in pulses area of the hyper-Ramsey protocol allows us to suppress the sensitivity of the clock resonance position to the residual light shift for a certain length of the medium. It is shown that using a combination of generalized hyper- Ramsey error signals allows us to suppress the sensitivity to the light shift for any length of the medium. Also we analyzed the effect of spontaneous decay of high atomic state on the light shift sensitivity of the composite pulses schemes.

arXiv:1907.10990•Jul 25, 2019•0 citations

Methods of generalized Ramsey spectroscopy in optically dense polyatomic ensembles

К. А. Баранцев, T. Zanon-Willette, A. N. Litvinov

In this work we investigate the methods of generalized Ramsey spectroscopy for high precision atomic clocks in the optically dense atomic ensembles. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied when taking into account the attenuation of the radiation intensity in the medium. Also we analyze the effect of spontaneous decay of high atomic state on the light shift sensitivity of the composite pulses schemes.

International Conference Laser Optics (ICLO)•Nov 2, 2020•0 citations

Composite laser-pulses spectroscopy for high-accuracy optical clocks: a review of recent progress and perspectives

T. Zanon-Willette, R. Lefèvre, Rémi Metzdorff +7 more

Probing an atomic resonance without disturbing it is an ubiquitous issue in physics. This problem is critical in high-accuracy spectroscopy or for the next generation of atomic optical clocks. Ultra-high resolution frequency metrology requires sophisticated interrogation schemes and robust protocols handling pulse length errors and residual frequency detuning offsets. This review reports recent progress and perspective in such schemes, using sequences of composite laser-pulses tailored in pulse duration, frequency and phase, inspired by NMR techniques and quantum information processing. After a short presentation of Rabi technique and NMR-like composite pulses allowing efficient compensation of electromagnetic field perturbations to achieve robust population transfers, composite laser-pulses are investigated within Ramsey's method of separated oscillating fields in order to generate non-linear compensation of probe-induced frequency shifts. Laser-pulses protocols such as hyper-Ramsey, modified hyper-Ramsey, generalized hyper-Ramsey and hybrid schemes as auto-balanced Ramsey spectroscopy are reviewed. These techniques provide excellent protection against both probe induced light-shift perturbations and laser intensity variations. More sophisticated schemes generating synthetic frequency-shifts are presented. They allow to reduce or completely eliminate imperfect correction of probe-induced frequency-shifts even in presence of decoherence due to the laser line-width. Finally, two universal protocols are presented which provide complete elimination of probe-induced frequency shifts in the general case where both decoherence and relaxation dissipation effects are present by using exact analytic expressions for phase-shifts and the clock frequency detuning. These techniques might be applied to atomic, molecular and nuclear frequency metrology, Ramsey-type mass spectrometry as well as precision spectroscopy.

arXiv:1806.04639•Reports on Progress in Physics•Jun 4, 2018•54 citations

Generalised hyper-Ramsey spectroscopy of two-level atoms in an optically dense medium

К. А. Баранцев, T. Zanon-Willette, A. N. Litvinov

Abstract The peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. Different composite pulse protocols for clock spectroscopy, including hyper-Ramsey, modified and generalised hyper-Ramsey schemes, are compared. Error signals change significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied with the attenuation of the radiation intensity in the medium taken into account. It is shown that using a combination of generalised hyper-Ramsey error signals allows one to suppress the sensitivity to the light shift for any length of the medium.

Quantum Electronics•Sep 28, 2020•2 citations
Ramsey schemes with pulses of different lengths and with a composite pulse have been analyzed taking into account a finite width of the laser line and spontaneous relaxation of atomic levels. The optimal parameters of pulses corresponding to the maximum suppression of the excitation-related shift and the maximum resonance amplitude have been found for both schemes. According to the numerical results, spontaneous relaxation of the atomic levels and a finite width of the laser line must be taken into account in the calculation of the optimal parameters of the excitation pulses. The Ramsey scheme with a composite pulse is less sensitive to fluctuations of the Rabi frequency than the scheme with pulses of different lengths.
We perform a theoretical analysis of the Ramsey scheme with pulses of different duration and with a phase step in the second pulse with account for the finite width of laser line. We define optimum features of pulses that correspond to maximum suppression of the field shift and maximum amplitude of resonance for both schemes. Ramsey scheme with a phase step in the second pulse provides effective suppression of the field shift and it is less sensitive to the Rabi frequency fluctuations in comparison with Ramsey scheme with pulses of different duration. First experiments on ytterbium single-ion optical clock (Germany, PTB) confirm theoretical predictions
In this work, the peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. We considered different composite pulse protocols for clock spectroscopy such as hyper-Ramsey, modified and generalized hyper-Ramsey schemes. Shapes of resonances and error signals changes significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is theoretically studied when taking into account the attenuation of the radiation intensity in the medium. The change in pulses area of the hyper-Ramsey protocol allows us to suppress the sensitivity of the clock resonance position to the residual light shift for a certain length of the medium. It is shown that using a combination of generalized hyper- Ramsey error signals allows us to suppress the sensitivity to the light shift for any length of the medium. Also we analyzed the effect of spontaneous decay of high atomic state on the light shift sensitivity of the composite pulses schemes.
In this work we investigate the methods of generalized Ramsey spectroscopy for high precision atomic clocks in the optically dense atomic ensembles. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied when taking into account the attenuation of the radiation intensity in the medium. Also we analyze the effect of spontaneous decay of high atomic state on the light shift sensitivity of the composite pulses schemes.
Probing an atomic resonance without disturbing it is an ubiquitous issue in physics. This problem is critical in high-accuracy spectroscopy or for the next generation of atomic optical clocks. Ultra-high resolution frequency metrology requires sophisticated interrogation schemes and robust protocols handling pulse length errors and residual frequency detuning offsets. This review reports recent progress and perspective in such schemes, using sequences of composite laser-pulses tailored in pulse duration, frequency and phase, inspired by NMR techniques and quantum information processing. After a short presentation of Rabi technique and NMR-like composite pulses allowing efficient compensation of electromagnetic field perturbations to achieve robust population transfers, composite laser-pulses are investigated within Ramsey's method of separated oscillating fields in order to generate non-linear compensation of probe-induced frequency shifts. Laser-pulses protocols such as hyper-Ramsey, modified hyper-Ramsey, generalized hyper-Ramsey and hybrid schemes as auto-balanced Ramsey spectroscopy are reviewed. These techniques provide excellent protection against both probe induced light-shift perturbations and laser intensity variations. More sophisticated schemes generating synthetic frequency-shifts are presented. They allow to reduce or completely eliminate imperfect correction of probe-induced frequency-shifts even in presence of decoherence due to the laser line-width. Finally, two universal protocols are presented which provide complete elimination of probe-induced frequency shifts in the general case where both decoherence and relaxation dissipation effects are present by using exact analytic expressions for phase-shifts and the clock frequency detuning. These techniques might be applied to atomic, molecular and nuclear frequency metrology, Ramsey-type mass spectrometry as well as precision spectroscopy.
Abstract The peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. Different composite pulse protocols for clock spectroscopy, including hyper-Ramsey, modified and generalised hyper-Ramsey schemes, are compared. Error signals change significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied with the attenuation of the radiation intensity in the medium taken into account. It is shown that using a combination of generalised hyper-Ramsey error signals allows one to suppress the sensitivity to the light shift for any length of the medium.