Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics B

Intrinsic relaxation rates of polarized Cs vapor in miniaturized cells

Theo Scholtes, Stefan Woetzel, R.P.J. IJsselsteijn, V. Schultze, Hans‐Georg Meyer

Published Apr 9, 2014• 22 citations
Publisher
DOI
10.1007/s00340-014-5824-z

Related papers

A large sample study of spin relaxation and magnetometric sensitivity of paraffin-coated Cs vapor cells

N. Castagna, G. Bison, G. Di Domenico +5 more

arXiv:0812.4425•Applied Physics B•Apr 2, 2009•80 citations

Study of the vapor cell size at high sensitive Cs magnetometer

Jiuxing Li, Qiang Liu, Qingmeng Li +2 more

The spin-exchange relaxation free (SERF) magnetometers are the most sensitive atomic magnetometers, the optimum sensitivity of which is on the order of 0.1 fTHz-1/2. The size of the vapor cell is important in the miniaturization of the Cs vapor magnetometer, for it determining other components'. The more importance is dependence of the spin-destruction rate, which is the maximum relaxation rate in the SERF regime. This paper presents the design of the vapor cell at Cs SERF magnetometers and the discussion of the highest sensitivity achieved in different sizes.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Nov 23, 2011•0 citations

Temperature Dependence of Electromagnetically Induced Transparency in a Cs Atomic Vapor Cell

H. G. Song, R. Choi, C. H. Oh

Journal of the Korean Physical Society•Jul 14, 2007•9 citations

Relaxation of atomic polarization in paraffin-coated cesium vapor cells

M. T. Graf, Derek F. Jackson Kimball, Simon Rochester +6 more

The relaxation of atomic polarization in buffer-gas-free, paraffin-coated cesium vapor cells is studied using a variation on Franzen's technique of ``relaxation in the dark'' [Franzen, Phys. Rev. 115 850 (1959)]. In the present experiment, narrow-band, circularly polarized pump light, resonant with the Cs D2 transition, orients atoms along a longitudinal magnetic field, and time-dependent optical rotation of linearly polarized probe light is measured to determine the relaxation rates of the atomic orientation of a particular hyperfine level. The change in relaxation rates during light-induced atomic desorption (LIAD) is studied. No significant change in the spin relaxation rate during LIAD is found beyond that expected from the faster rate of spin-exchange collisions due to the increase in Cs density.

arXiv:physics/0503202•Physical Review A•Aug 1, 2005•140 citations

Spin relaxation in alkali vapors

Stephen J. Kadlecek

•Nov 1, 1999•4 citations

Spin-exchange-relaxation-free magnetometry with Cs vapor

M. P. Ledbetter, Igor Savukov, Víctor M. Acosta +2 more

We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about $400\text{ }\text{pG}/\sqrt{\text{Hz}}$. Based on photon shot noise, we project a sensitivity of $40\text{ }\text{pG}/\sqrt{\text{Hz}}$. A theoretical optimization of the magnetometer indicates sensitivities on the order of $2\text{ }\text{pG}/\sqrt{\text{Hz}}$ should be achievable in a $1\text{ }{\text{cm}}^{3}$ volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.

arXiv:0708.1012•Physical Review A•Mar 13, 2008•408 citations
The spin-exchange relaxation free (SERF) magnetometers are the most sensitive atomic magnetometers, the optimum sensitivity of which is on the order of 0.1 fTHz-1/2. The size of the vapor cell is important in the miniaturization of the Cs vapor magnetometer, for it determining other components'. The more importance is dependence of the spin-destruction rate, which is the maximum relaxation rate in the SERF regime. This paper presents the design of the vapor cell at Cs SERF magnetometers and the discussion of the highest sensitivity achieved in different sizes.
The relaxation of atomic polarization in buffer-gas-free, paraffin-coated cesium vapor cells is studied using a variation on Franzen's technique of ``relaxation in the dark'' [Franzen, Phys. Rev. 115 850 (1959)]. In the present experiment, narrow-band, circularly polarized pump light, resonant with the Cs D2 transition, orients atoms along a longitudinal magnetic field, and time-dependent optical rotation of linearly polarized probe light is measured to determine the relaxation rates of the atomic orientation of a particular hyperfine level. The change in relaxation rates during light-induced atomic desorption (LIAD) is studied. No significant change in the spin relaxation rate during LIAD is found beyond that expected from the faster rate of spin-exchange collisions due to the increase in Cs density.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400 pG/Hz400\text{ }\text{pG}/\sqrt{\text{Hz}}400 pG/Hz​. Based on photon shot noise, we project a sensitivity of 40 pG/Hz40\text{ }\text{pG}/\sqrt{\text{Hz}}40 pG/Hz​. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2 pG/Hz2\text{ }\text{pG}/\sqrt{\text{Hz}}2 pG/Hz​ should be achievable in a 1 cm31\text{ }{\text{cm}}^{3}1 cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.