The spin-exchange relaxation free (SERF) magnetometers are the most sensitive atomic magnetometers, the optimum sensitivity of which is on the order of 0.1 fTHz-1/2. The size of the vapor cell is important in the miniaturization of the Cs vapor magnetometer, for it determining other components'. The more importance is dependence of the spin-destruction rate, which is the maximum relaxation rate in the SERF regime. This paper presents the design of the vapor cell at Cs SERF magnetometers and the discussion of the highest sensitivity achieved in different sizes.
The relaxation of atomic polarization in buffer-gas-free, paraffin-coated cesium vapor cells is studied using a variation on Franzen's technique of ``relaxation in the dark'' [Franzen, Phys. Rev. 115 850 (1959)]. In the present experiment, narrow-band, circularly polarized pump light, resonant with the Cs D2 transition, orients atoms along a longitudinal magnetic field, and time-dependent optical rotation of linearly polarized probe light is measured to determine the relaxation rates of the atomic orientation of a particular hyperfine level. The change in relaxation rates during light-induced atomic desorption (LIAD) is studied. No significant change in the spin relaxation rate during LIAD is found beyond that expected from the faster rate of spin-exchange collisions due to the increase in Cs density.
We describe a Cs atomic magnetometer operating in the spin-exchange-relaxation-free (SERF) regime. With a vapor cell temperature of $103\text{ }\ifmmode^\circ\else\textdegree\fi{}\text{C}$ we achieve intrinsic magnetic resonance widths $\ensuremath{\Delta}B=17\text{ }\ensuremath{\mu}\text{G}$ corresponding to an electron spin-relaxation rate of $300\text{ }{\text{s}}^{\ensuremath{-}1}$ when the spin-exchange rate is ${\ensuremath{\Gamma}}_{\text{SE}}=14\text{ }000\text{ }{\text{s}}^{\ensuremath{-}1}$. We also observe an interesting narrowing effect due to diffusion. Signal-to-noise measurements yield a sensitivity of about 400pG/Hz. Based on photon shot noise, we project a sensitivity of 40pG/Hz. A theoretical optimization of the magnetometer indicates sensitivities on the order of 2pG/Hz should be achievable in a 1cm3 volume. Because Cs has a higher saturated vapor pressure than other alkali metals, SERF magnetometers using Cs atoms are particularly attractive in applications requiring lower temperatures.