A fully quantum-mechanical treatment is given of field and population fluctuations in a homogeneously broadened laser. The field and population reservoirs have been replaced by dissipation coefficients (or transition probabilities) and noncommuting noise sources. The atomic polarization variables are adiabatically eliminated. The mean motion of an arbitrary operator function $M(b, {b}^{\ifmmode\dagger\else\textdagger\fi{}}, {N}_{1}, {N}_{2})$ of the field variables
b, ${b}^{\ifmmode\dagger\else\textdagger\fi{}}$ and the population variables
N1 and
N2 is calculated. The equation of motion for the density matrix $\ensuremath{\rho}(b, {b}^{\ifmmode\dagger\else\textdagger\fi{}}, {N}_{1}, {N}_{2}, t)$ is deduced, as well as the Fokker-Planck equation for the associated classical distribution function $P(\ensuremath{\beta}, {\ensuremath{\beta}}^{*}, {N}_{1}, {N}_{2}, t)$. The diffusion coefficients in the latter equation demonstrate the shot-noise origin of the fluctuations. The Fokker-Planck equation for
P is replaced by Langevin equations for $\ensuremath{\beta}$, ${\ensuremath{\beta}}^{*}$,
N1, and
N2 to facilitate adiabatic elimination of the population variables (when valid). The resulting Langevin equations for $\ensuremath{\beta}$, ${\ensuremath{\beta}}^{*}$ are converted to a Fokker-Planck equation for $P(\ensuremath{\beta}, {\ensuremath{\beta}}^{*}, t)$, to an operator equation for $\ensuremath{\rho}(b, {b}^{\ifmmode\dagger\else\textdagger\fi{}}, t)$, and to an equation for ${\ensuremath{\rho}}_{\mathrm{mn}}$, the field density matrix in the photon-number representation. The transformation $\ensuremath{\beta}={I}^{\frac{1}{2}}{e}^{\ensuremath{-}i\ensuremath{\phi}}$ to an ($I, \ensuremath{\phi}$) representation leads (a) to the steady-state solution
P(I) valid at all operating levels, and (b) to the phase linewidth. The transformation to new variables
N=21(m+n), $k=m\ensuremath{-}n$, permits the equation for ${\ensuremath{\rho}}_{\mathrm{mn}}$ to be replaced by a Fokker-Planck equation for $\ensuremath{\rho}(N, k, t)$. The latter permits a verification of the previously obtained phase linewidth and a solution for the steady-state $\ensuremath{\rho}(N)$.
In this paper we start from our Quantum Noise IV model of a homogenously broadened maser and specialize to the case in which the number of photons and the population difference are the slowest changing variables. In spite of the high coherence of the system, we find that by eliminating all other variables adiabatically we obtain the usual rate equations plus a set of noise sources with precisely those moments appropriate to shot noise. Thus we justify McCumber's model for amplitude noise in a laser, and after making a quasi-linear approximation obtain his amplitude spectrum. Comparison with exact calculations of Hempstead and Lax for the rotating wave van der Pol oscillator suggests that quasi-linear methods are accurate except within a factor 10 (in photon number) of threshold.
A dynamic correspondence is set up between the density matrix of the electromagnetic field and an associated classical function. Means of one and two time quantum operators are shown to be obtainable from the corresponding averages of the associated classical random problem. When all atomic response rates are fast compared to photon rates, the equation of motion is obtained for the field density matrix. The associated classical problem is shown to obey a Fokker-Planck equation. Over a broad region that includes the threshold region, the Fokker-Planck equation is reduced to that for the rotating-wave van der Pol oscillator for which exact numerical solutions have been previously obtained by Hempstead and Lax.
As discussed in the last three chapters, the fundamental source of noise in a laser is spontaneous emission. A simple pictorial model for the origin of the laser linewidth envisions it as being due to the random phase diffusion process arising from the addition of spontaneously emitted photons with random phases to the laser field. In this chapter we show that the quantum noise leading to the laser linewidth can be suppressed below the standard, i.e., Schawlow–Townes limit by preparing the atomic systems in a coherent superposition of states as in the Hanle effect and quantum beat experiments discussed in Chapter 7. In such coherently prepared atoms the spontaneous emission is said to be correlated. Lasers operating via such a phase coherent atomic ensemble are known as correlated spontaneous emission lasers (CEL). An interesting aspect of the CEL is that it is possible to eliminate the spontaneous emission quantum noise in the relative linewidths by correlating the two spontaneous emission noise events. A number of schemes exist in which quantum noise quenching below the standard limit can be achieved. In two-mode schemes a correlation between the spontaneous emisson events in two different modes of the radiation field is established via atomic coherence so that the relative phase between them does not diffuse or fluctuate. In a Hanle laser and a quantum beat laser this is achieved by pumping the atoms coherently such that every spontaneously emitting atom contributes equally to the two modes of the radiation, leading to a reduction and even vanishing of the noise in the phase difference.
We consider the problem of reducing the contributions of pump and spontaneous-emission noise to the output noise of a laser field. We consider two models based on an atomic medium, one analytic, the other involving numerical simulation of a sequence of pump cycles. The predictions of both models are shown to agree. For regular pump excitation the intensity fluctuations of a laser well above threshold may be reduced to zero at the cavity resonance frequency if the ratio of the lifetimes of the upper and lower lasing levels is sufficiently large that spontaneous emission is suppressed. When the atomic lifetimes are comparable, spontaneous emission reduces the amount of noise reduction. For example, for equal atomic lifetimes regular pump excitation will result in a maximum noise reduction in the output field of one-half the shot-noise limit.