Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Communications

Optimized temperature measurement with time-of-flight method

Haichao Zhang, Pengfei Zhang, Xinping Xu, Feng Cheng, Yuzhu Wang

Published May 31, 2009• 5 citations
Publisher
DOI
10.1016/j.optcom.2009.05.030

Related papers

Measurement of Temperature of Atomic Cloud Using Time-of-Flight Technique

Poonam Arora, Subhajit Banerjee Purnapatra, Aishik Acharya +2 more

MAPAN•Mar 1, 2012•13 citations

Temperature Measurement Using a Transmon Device

Henrik Lievonen

•Sep 29, 2020•0 citations

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

Improvement on Temperature Measurement of Cold Atoms in a Rubidium Fountain

Desheng Lü, Qiuzhi Qu, Bin Wang +3 more

The time-of-flight (TOF) method is one of the most common ways to measure the temperature of cold atoms. In the cold atomic fountain setup, the geometry of the probe beam will introduce the measurement errors to the spatial distribution of cold atomic cloud, which will lead to the measurement errors on atomic temperature. Using deconvolution, we recover the atomic cloud profile from the TOF signal. Then, we use the recovered signals other than the TOF signals to obtain a more accurate atomic temperature. This will be important in estimating the effects of cold atom collision shift and the shift due to transverse cavity phase distribution on an atomic fountain clock.

Chinese Physics Letters•Jun 1, 2011•10 citations

Efficient finite-time measurements under thermal regimes

Carlos Alexandre Brasil, Leonardo Andreta de Castro, Reginaldo de Jesus Napolitano

arXiv:1309.3621•The European Physical Journal Plus•Sep 30, 2014•5 citations

New method for temperature measurement of cold atoms in Cs fountain clocks

Mario González Espinosa, Edgar Carlos, J. M. López +2 more

We report a novel method for temperature measurement in a cesium fountain clock and experimental investigation about its dependence respect to diverse operational parameters. The temperature of the Cs atomic cloud is inferred from the width of the velocity distribution, which is obtained from two measurements in different regions of the spatial distribution of the atomic cloud using the time of flight (TOF) method. We use a simple process to determine the velocity distribution by calculating the square speed point by point from these two TOF signals. This new method is demonstrated to characterize the temperature of the Cs atoms on the CENAM Cs fountain clock. The minimum temperature reached in the CENAM Cs fountain clock is 612(193) nK.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
The time-of-flight (TOF) method is one of the most common ways to measure the temperature of cold atoms. In the cold atomic fountain setup, the geometry of the probe beam will introduce the measurement errors to the spatial distribution of cold atomic cloud, which will lead to the measurement errors on atomic temperature. Using deconvolution, we recover the atomic cloud profile from the TOF signal. Then, we use the recovered signals other than the TOF signals to obtain a more accurate atomic temperature. This will be important in estimating the effects of cold atom collision shift and the shift due to transverse cavity phase distribution on an atomic fountain clock.
We report a novel method for temperature measurement in a cesium fountain clock and experimental investigation about its dependence respect to diverse operational parameters. The temperature of the Cs atomic cloud is inferred from the width of the velocity distribution, which is obtained from two measurements in different regions of the spatial distribution of the atomic cloud using the time of flight (TOF) method. We use a simple process to determine the velocity distribution by calculating the square speed point by point from these two TOF signals. This new method is demonstrated to characterize the temperature of the Cs atoms on the CENAM Cs fountain clock. The minimum temperature reached in the CENAM Cs fountain clock is 612(193) nK.