Chinese Physics Letters

Improvement on Temperature Measurement of Cold Atoms in a Rubidium Fountain

Desheng Lü, Qiuzhi Qu, Bin Wang, Jian-Bo Zhao, Liang Liu, Yuzhu Wang

Published Jun 1, 2011• 10 citations
Publisher

Abstract

The time-of-flight (TOF) method is one of the most common ways to measure the temperature of cold atoms. In the cold atomic fountain setup, the geometry of the probe beam will introduce the measurement errors to the spatial distribution of cold atomic cloud, which will lead to the measurement errors on atomic temperature. Using deconvolution, we recover the atomic cloud profile from the TOF signal. Then, we use the recovered signals other than the TOF signals to obtain a more accurate atomic temperature. This will be important in estimating the effects of cold atom collision shift and the shift due to transverse cavity phase distribution on an atomic fountain clock.

DOI
10.1088/0256-307x/28/6/063201

Related papers

New method for temperature measurement of cold atoms in Cs fountain clocks

Mario González Espinosa, Edgar Carlos, J. M. López +2 more

We report a novel method for temperature measurement in a cesium fountain clock and experimental investigation about its dependence respect to diverse operational parameters. The temperature of the Cs atomic cloud is inferred from the width of the velocity distribution, which is obtained from two measurements in different regions of the spatial distribution of the atomic cloud using the time of flight (TOF) method. We use a simple process to determine the velocity distribution by calculating the square speed point by point from these two TOF signals. This new method is demonstrated to characterize the temperature of the Cs atoms on the CENAM Cs fountain clock. The minimum temperature reached in the CENAM Cs fountain clock is 612(193) nK.

Conference on Precision Electromagnetic Measurements•Jul 1, 2012•0 citations

Alternative Algorithm for Temperature Measurements of Cold Atoms in Cs Fountain Clocks

Maria G. Espinosa-Olivares, Eduardo de Carlos-Lopez, José Mauricio López-Romero +1 more

We report an alternative algorithm to the deconvolution method for obtaining Gaussian velocity distribution for temperature measurements in Cs fountain clocks. We estimate the velocity distribution of the cloud of cold atoms from time-of-flight signals, at different times, by calculating the square speed point by point (PBP). Then, the temperature of the Cs atomic cloud is inferred from the width (e-1/2) of the velocity distribution. We have done an exhaustive comparison of the PBP algorithm with the deconvolution method using both theoretical and experimental data for Gaussian velocity distributions. Finally, when comparing the process to obtain the velocity distribution in both the PBP algorithm and the deconvolution method, it is found that our approach is easier to implement and automate.

IEEE Transactions on Instrumentation and Measurement•Jan 28, 2015•2 citations

Temperature measurement of cold atoms in a cesium magneto-optical trap by means of short-distance time-of-flight absorption spectrum

Tao Geng, 闫树斌 Yan Shubin, Yanhua Wang +4 more

We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.

Acta Physica Sinica•Jan 1, 2005•7 citations

A method of accurately determining temperature of cold atomic cloud in atomic fountain

Junru Shi, Xinliang Wang, Yong Guan +8 more

The Gaussian radius and temperature of cold atomic cloud are important parameters in describing the state of cold atoms. The precise measuring of these two parameters is of great significance for studying the cold atoms. In this paper, we propose a new method named knife-edge to measure the Gaussian radius and temperature of the cold atomic cloud. A near-resonant and supersaturated laser beam, whose size is controlled by a knife-edge aperture, is used to push away the cold atoms in the free falling process of cold atomic cloud. By detecting the intensity of fluorescence signal, the numbers of residual atoms under different-sized near-resonant beams can be obtained. According to the characteristic of cold atoms′ distribution, we construct a theoretical model to derive the Gaussian radius of cold atomic cloud from the recorded residual atom number and near-resonant beam size. Since the Gaussian radius and temperature of cold atomic cloud are associated with each other, we can finally obtain the temperature of cold atomic cloud through the recorded residual atom number and beam size. By using this method, we successfully measure the Gaussian radii of cold atomic cloud at the heights of 10 mm and 160 mm below the center of 3D-MOT (three dimensional magneto-optical trap) to be (1.54 ± 0.05) mm and (3.29 ± 0.08) mm, respectively. The corresponding temperature of cold atomic cloud is calculated to be (7.50 ± 0.49) μK, which is well consistent with the experimental result obtained by using the time-of-flight method under the same condition. This experiment is conducted on the platform of Cesium atomic fountain clock of National Time Service Center, China.

Acta Physica Sinica•Jan 1, 2019•3 citations

Optical molasses loaded from a slow atomic beam

Shougang Zhang

Preparation of the optical molasses is one of the key steps for developing a fountain clock.The optical molasses is loaded from a slow atomic beam,and the fluorescence collection method is applied to determine the number of atoms in the optical molasses,meanwhile the time-of-flight(TOF) method is used to measure the temperature of the optical molasses.The number of cold atoms in the optical molasses for loading time of 200 ms is determined to be(8.14±0.2)×107,and the temperature of cold atoms is determined to be(10.72±0.69) μK.

Journal of Time and Frequency•Jan 1, 2012•0 citations

Reliable algorithm for estimation of the temperature of cooled atoms

Elena Stoykova, Jean-Claude Keller

A reliable algorithm for temperature estimation of cooled atoms is proposed and investigated by 2D-Monte-Carlo simulation for the ensemble of 133Cs atoms provided time-of-flight (TOF) and spatial distributions of falling atoms are found in two planes below the atomic cloud using fluorescence or transmission measurements. We assume that the atoms, being normally distributed in space, are left to fall freely at a certain moment and we suppose that collisions between them do not cause substantial distortion of the ideal TOF-distribution.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 7, 1999•0 citations
The time-of-flight (TOF) method is one of the most common ways to measure the temperature of cold atoms. In the cold atomic fountain setup, the geometry of the probe beam will introduce the measurement errors to the spatial distribution of cold atomic cloud, which will lead to the measurement errors on atomic temperature. Using deconvolution, we recover the atomic cloud profile from the TOF signal. Then, we use the recovered signals other than the TOF signals to obtain a more accurate atomic temperature. This will be important in estimating the effects of cold atom collision shift and the shift due to transverse cavity phase distribution on an atomic fountain clock.
We report a novel method for temperature measurement in a cesium fountain clock and experimental investigation about its dependence respect to diverse operational parameters. The temperature of the Cs atomic cloud is inferred from the width of the velocity distribution, which is obtained from two measurements in different regions of the spatial distribution of the atomic cloud using the time of flight (TOF) method. We use a simple process to determine the velocity distribution by calculating the square speed point by point from these two TOF signals. This new method is demonstrated to characterize the temperature of the Cs atoms on the CENAM Cs fountain clock. The minimum temperature reached in the CENAM Cs fountain clock is 612(193) nK.
We report an alternative algorithm to the deconvolution method for obtaining Gaussian velocity distribution for temperature measurements in Cs fountain clocks. We estimate the velocity distribution of the cloud of cold atoms from time-of-flight signals, at different times, by calculating the square speed point by point (PBP). Then, the temperature of the Cs atomic cloud is inferred from the width (e-1/2) of the velocity distribution. We have done an exhaustive comparison of the PBP algorithm with the deconvolution method using both theoretical and experimental data for Gaussian velocity distributions. Finally, when comparing the process to obtain the velocity distribution in both the PBP algorithm and the deconvolution method, it is found that our approach is easier to implement and automate.
We report the basic idea and experimental demonstration of measuring the temperature of cold cesium atomic cloud confined in a magneto-optical trap (MOT) by analyzing absorption spectrum observed in the short-distance time-of-flight (TOF) method. Compared with the conventional TOF scheme, we measure the temperature of cold atomic cloud in MOT by short-distance TOF method for our small vapor cell. If the cold atomic cloud is released, it will fall and expand due to gravity and its initial velocity distribution. Utilizing a cylindrical resonant probe beam positioned several millimeters beneath the MOT (in this paper, we analyzed the cases for 3mm, 5mm, and 8mm of center-to-center distance between the MOT region and the probe beam, respectively), we can record the short-distance TOF absorption spectrum with a photodiode when cold atoms go through the probe region. Analysis of the short-distance TOF absorption spectrum yields the effective temperature of the cold cloud in MOT.
The Gaussian radius and temperature of cold atomic cloud are important parameters in describing the state of cold atoms. The precise measuring of these two parameters is of great significance for studying the cold atoms. In this paper, we propose a new method named knife-edge to measure the Gaussian radius and temperature of the cold atomic cloud. A near-resonant and supersaturated laser beam, whose size is controlled by a knife-edge aperture, is used to push away the cold atoms in the free falling process of cold atomic cloud. By detecting the intensity of fluorescence signal, the numbers of residual atoms under different-sized near-resonant beams can be obtained. According to the characteristic of cold atoms′ distribution, we construct a theoretical model to derive the Gaussian radius of cold atomic cloud from the recorded residual atom number and near-resonant beam size. Since the Gaussian radius and temperature of cold atomic cloud are associated with each other, we can finally obtain the temperature of cold atomic cloud through the recorded residual atom number and beam size. By using this method, we successfully measure the Gaussian radii of cold atomic cloud at the heights of 10 mm and 160 mm below the center of 3D-MOT (three dimensional magneto-optical trap) to be (1.54 ± 0.05) mm and (3.29 ± 0.08) mm, respectively. The corresponding temperature of cold atomic cloud is calculated to be (7.50 ± 0.49) μK, which is well consistent with the experimental result obtained by using the time-of-flight method under the same condition. This experiment is conducted on the platform of Cesium atomic fountain clock of National Time Service Center, China.
Preparation of the optical molasses is one of the key steps for developing a fountain clock.The optical molasses is loaded from a slow atomic beam,and the fluorescence collection method is applied to determine the number of atoms in the optical molasses,meanwhile the time-of-flight(TOF) method is used to measure the temperature of the optical molasses.The number of cold atoms in the optical molasses for loading time of 200 ms is determined to be(8.14±0.2)×107,and the temperature of cold atoms is determined to be(10.72±0.69) μK.
A reliable algorithm for temperature estimation of cooled atoms is proposed and investigated by 2D-Monte-Carlo simulation for the ensemble of 133Cs atoms provided time-of-flight (TOF) and spatial distributions of falling atoms are found in two planes below the atomic cloud using fluorescence or transmission measurements. We assume that the atoms, being normally distributed in space, are left to fall freely at a certain moment and we suppose that collisions between them do not cause substantial distortion of the ideal TOF-distribution.