Journal of Physics B Atomic Molecular and Optical Physics

Phase-sensitive measurement of trapped particle motions

S. Ståhl, Joseba Alonso, S. Djekić, H.‐J. Kluge, W. Quint, J. Verdú, Manuel Vogel, Günther Werth

Published Jan 25, 2005• 38 citations
Publisher

Abstract

We have developed and applied a novel method for the precise determination of small frequency differences of particle motions inside a Penning trap. In the present case, the frequency differences on the order of 100 mHz at motional frequencies on the order of 1 MHz are used to determine the spin state of an electron bound in a hydrogen-like ion. This novel technique measures the integrated phase difference of the particles' motions relative to an excitation with a well-defined phase. Thereby, the Fourier-limit for frequency measurements based on Fourier-analyses of detection signals can be overcome.

DOI
10.1088/0953-4075/38/3/013

Related papers

Ion trap frequency measurement from fluorescence dynamics

Kota Saito, Ryoichi Saito, Takashi Mukaiyama

In this paper, we propose and demonstrate a new method for measuring the trap frequency from the fluorescence dynamics of an ion, initiated using fast trap-center displacement. Here, we observe the coherently excited motion of an ion in a harmonic trap using time-resolved fluorescence detection. Furthermore, Fourier analysis of the ion fluorescence signal was used to determine the trap frequency of an ion with high precision and reproducibility. The results show that our proposed method can be an alternative way to determine trap frequencies in an ion trap experiment.

Journal of Applied Physics•Sep 1, 2022•4 citations

Electronic detection of charged particle effects in a Penning trap

D. Winters, Manuel Vogel, D. M. Segal +1 more

We present a thorough analysis of the electronic detection of charged particles, confined in a Penning trap, via image charges induced in the trap electrodes. Trapping of charged particles in an electrode structure leads to frequency shifts, which are due to image charge and space charge effects. These effects are of importance for Penning trap experiments which involve high charge densities or require high precision in the motional frequencies. Our analysis of image charges shows that only (higher order) odd powers of the particle displacement lead to induced charge differences, giving rise to a signal. This implies that, besides the centre-of-mass frequency of a trapped particle cloud, also higher order individual particle frequencies induce a signal, which can be picked up by an electronic detection circuit attached to the trap electrodes. We also derive analytic expressions for the image charge and space charge induced frequency shifts and perform simulations of space charge effects. In relation to this, we discuss the consequences of the shifted particle frequencies for resistive cooling of the particle motion.

arXiv:physics/0608055•Journal of Physics B Atomic Molecular and Optical Physics•Jul 11, 2006•36 citations

YoctoNewton force detection sensitivity using trapped ions

Michael J. Biercuk, Hermann Uys, J. Britton +2 more

The ability to detect extremely small forces is vital for a variety of disciplines including precision spin-resonance imaging, microscopy, and tests of fundamental physical phenomena. Current force-detection sensitivity limits have surpassed 1 $aN/\sqrt{Hz}$ (atto $=10^{-18}$) through coupling of micro or nanofabricated mechanical resonators to a variety of physical systems including single-electron transistors, superconducting microwave cavities, and individual spins. These experiments have allowed for probing studies of a variety of phenomena, but sensitivity requirements are ever-increasing as new regimes of physical interactions are considered. Here we show that trapped atomic ions are exquisitely sensitive force detectors, with a measured sensitivity more than three orders of magnitude better than existing reports. We demonstrate detection of forces as small as 174 $yN$ (yocto $=10^{-24}$), with a sensitivity 390$\pm150$ $yN/\sqrt{Hz}$ using crystals of $n=60$ $^{9}$Be$^{+}$ ions in a Penning trap. Our technique is based on the excitation of normal motional modes in an ion trap by externally applied electric fields, detection via and phase-coherent Doppler velocimetry, which allows for the discrimination of ion motion with amplitudes on the scale of nanometers. These experimental results and extracted force-detection sensitivities in the single-ion limit validate proposals suggesting that trapped atomic ions are capable of detecting of forces with sensitivity approaching 1 $yN/\sqrt{Hz}$. We anticipate that this demonstration will be strongly motivational for the development of a new class of deployable trapped-ion-based sensors, and will permit scientists to access new regimes in materials science.

arXiv:1004.0780•Apr 6, 2010•0 citations

Phase-coherent sensing of the center-of-mass motion of trapped-ion crystals

M. Affolter, Kevin Gilmore, J. E. Jordan +1 more

Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A $49\phantom{\rule{4pt}{0ex}}\mathrm{pm}$ displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an $8.4\phantom{\rule{4pt}{0ex}}\mathrm{pm}/\sqrt{\mathrm{Hz}}$ displacement sensitivity is achieved, which implies $12\phantom{\rule{0.16em}{0ex}}(\mathrm{yN}/\mathrm{ion})/\sqrt{\mathrm{Hz}}$ and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and $1\phantom{\rule{4pt}{0ex}}\mathrm{nV}$/m, respectively.

arXiv:2008.00035•Physical Review A•Nov 9, 2020•25 citations

Theoretical study on rotation measurement with quantum vibration oscillators based on ion crystal in a Penning trap

Yao Chen, Ruyang Guo, Ju Guo +2 more

In traditional mechanics, harmonic oscillators can be used to measure force, acceleration, or rotation. Herein, we describe a quantum harmonic oscillator based on a Penning-trapped calcium ion crystal. Similar to traditional oscillators, the Coriolis force-induced axial oscillation amplitude is precisely measured to determine the input velocity. We show that the magnetron motion can be controlled through the rotating wall driving and treated as the driving oscillator. The Coriolis force couples with the magnetron motion and induces vibration in the axial direction or the z direction. The center of mass motion of the ion crystal in the axial direction could be precisely detected by the entanglement between the spins of the ions and the harmonic motion through lasers. The frequency of the magnetron motion needs to meet that of the axial motion under certain conditions, and, thus, the axial motion could be tuned to the resonance peak for maximum detection signal. We provided the parameter spaces for the matching of the magnetron frequencies with those of the axial frequencies. The measurement sensitivity was calculated in detail, and results show that a rotation angular velocity of 3.0×10−9rad/s/Hz could be achieved with 10 000 ions. Amplitude sensing could reach a sensitivity of 0.4 pm/Hz. With spin squeezing, the sensitivity could be further improved.

AVS Quantum Science•Sep 1, 2025•0 citations

QND measurements and wave function collapse in penning traps

Irene Marzoli, Paolo Tombesi

The attained precision of measurements in Penning traps is so high that, for light particles, the relativistic corrections are detectable. Thus, the coupling among the various motions of the trapped particle is provided by the relativistic shift of the mass. A parallel LCR circuit interacting with the elastically bound particle represents the measurement device. The measurement is performed by monitoring the resonance frequency of the spectral function of the output voltage.

Annual Meeting Optical Society of America•Jan 1, 1993•0 citations
We have developed and applied a novel method for the precise determination of small frequency differences of particle motions inside a Penning trap. In the present case, the frequency differences on the order of 100 mHz at motional frequencies on the order of 1 MHz are used to determine the spin state of an electron bound in a hydrogen-like ion. This novel technique measures the integrated phase difference of the particles' motions relative to an excitation with a well-defined phase. Thereby, the Fourier-limit for frequency measurements based on Fourier-analyses of detection signals can be overcome.
In this paper, we propose and demonstrate a new method for measuring the trap frequency from the fluorescence dynamics of an ion, initiated using fast trap-center displacement. Here, we observe the coherently excited motion of an ion in a harmonic trap using time-resolved fluorescence detection. Furthermore, Fourier analysis of the ion fluorescence signal was used to determine the trap frequency of an ion with high precision and reproducibility. The results show that our proposed method can be an alternative way to determine trap frequencies in an ion trap experiment.
We present a thorough analysis of the electronic detection of charged particles, confined in a Penning trap, via image charges induced in the trap electrodes. Trapping of charged particles in an electrode structure leads to frequency shifts, which are due to image charge and space charge effects. These effects are of importance for Penning trap experiments which involve high charge densities or require high precision in the motional frequencies. Our analysis of image charges shows that only (higher order) odd powers of the particle displacement lead to induced charge differences, giving rise to a signal. This implies that, besides the centre-of-mass frequency of a trapped particle cloud, also higher order individual particle frequencies induce a signal, which can be picked up by an electronic detection circuit attached to the trap electrodes. We also derive analytic expressions for the image charge and space charge induced frequency shifts and perform simulations of space charge effects. In relation to this, we discuss the consequences of the shifted particle frequencies for resistive cooling of the particle motion.
The ability to detect extremely small forces is vital for a variety of disciplines including precision spin-resonance imaging, microscopy, and tests of fundamental physical phenomena. Current force-detection sensitivity limits have surpassed 1 aN/HzaN/\sqrt{Hz}aN/Hz​ (atto =10−18=10^{-18}=10−18) through coupling of micro or nanofabricated mechanical resonators to a variety of physical systems including single-electron transistors, superconducting microwave cavities, and individual spins. These experiments have allowed for probing studies of a variety of phenomena, but sensitivity requirements are ever-increasing as new regimes of physical interactions are considered. Here we show that trapped atomic ions are exquisitely sensitive force detectors, with a measured sensitivity more than three orders of magnitude better than existing reports. We demonstrate detection of forces as small as 174 yNyNyN (yocto =10−24=10^{-24}=10−24), with a sensitivity 390±150\pm150±150 yN/HzyN/\sqrt{Hz}yN/Hz​ using crystals of n=60n=60n=60 9^{9}9Be+^{+}+ ions in a Penning trap. Our technique is based on the excitation of normal motional modes in an ion trap by externally applied electric fields, detection via and phase-coherent Doppler velocimetry, which allows for the discrimination of ion motion with amplitudes on the scale of nanometers. These experimental results and extracted force-detection sensitivities in the single-ion limit validate proposals suggesting that trapped atomic ions are capable of detecting of forces with sensitivity approaching 1 yN/HzyN/\sqrt{Hz}yN/Hz​. We anticipate that this demonstration will be strongly motivational for the development of a new class of deployable trapped-ion-based sensors, and will permit scientists to access new regimes in materials science.
Trapped ions are sensitive detectors of weak forces and electric fields that excite ion motion. Here measurements of the center-of-mass motion of a trapped-ion crystal that are phase coherent with an applied weak external force are reported. These experiments are conducted far from the trap motional frequency on a two-dimensional trapped-ion crystal of approximately 100 ions, and determine the fundamental measurement imprecision of our protocol free from noise associated with the center-of-mass mode. The driven sinusoidal displacement of the crystal is detected by coupling the ion crystal motion to the internal spin degree of freedom of the ions using an oscillating spin-dependent optical dipole force. The resulting induced spin precession is proportional to the displacement amplitude of the crystal, and is measured with near-projection-noise-limited resolution. A 49pm49\phantom{\rule{4pt}{0ex}}\mathrm{pm}49pm displacement is detected with a signal-to-noise ratio of 1 in a single experimental determination, which is an order-of-magnitude improvement over prior phase-incoherent experiments. This displacement amplitude is 40 times smaller than the zero-point fluctuations. With our repetition rate, an 8.4pm/Hz8.4\phantom{\rule{4pt}{0ex}}\mathrm{pm}/\sqrt{\mathrm{Hz}}8.4pm/Hz​ displacement sensitivity is achieved, which implies 12(yN/ion)/Hz12\phantom{\rule{0.16em}{0ex}}(\mathrm{yN}/\mathrm{ion})/\sqrt{\mathrm{Hz}}12(yN/ion)/Hz​ and $77\phantom{\rule{0.16em}{0ex}}(\ensuremath{\mu}\mathrm{V}/\mathrm{m})/\sqrt{\mathrm{Hz}}$ sensitivities to forces and electric fields, respectively. This displacement sensitivity, when applied on-resonance with the center-of-mass mode, indicates the possibility of weak force and electric field detection below ${10}^{\ensuremath{-}3}\phantom{\rule{4pt}{0ex}}\mathrm{yN}$/ion and 1nV1\phantom{\rule{4pt}{0ex}}\mathrm{nV}1nV/m, respectively.
In traditional mechanics, harmonic oscillators can be used to measure force, acceleration, or rotation. Herein, we describe a quantum harmonic oscillator based on a Penning-trapped calcium ion crystal. Similar to traditional oscillators, the Coriolis force-induced axial oscillation amplitude is precisely measured to determine the input velocity. We show that the magnetron motion can be controlled through the rotating wall driving and treated as the driving oscillator. The Coriolis force couples with the magnetron motion and induces vibration in the axial direction or the z direction. The center of mass motion of the ion crystal in the axial direction could be precisely detected by the entanglement between the spins of the ions and the harmonic motion through lasers. The frequency of the magnetron motion needs to meet that of the axial motion under certain conditions, and, thus, the axial motion could be tuned to the resonance peak for maximum detection signal. We provided the parameter spaces for the matching of the magnetron frequencies with those of the axial frequencies. The measurement sensitivity was calculated in detail, and results show that a rotation angular velocity of 3.0×10−9rad/s/Hz could be achieved with 10 000 ions. Amplitude sensing could reach a sensitivity of 0.4 pm/Hz. With spin squeezing, the sensitivity could be further improved.