IEEE Transactions on Magnetics

Quantum noise in SQUIDs

Вадим Васильевич Данилов, K. K. Likharev, Alexander B Zorin

Published May 1, 1983• 47 citations
Publisher

Abstract

The sensitivity limitations due to thermal, quantum and shot noise are calculated for dc and ac SQUIDs. Two approximations are used for the Josephson junctions: i. RSJ model with the equilibrium source of thermal-and-quantum fluctuations and ii. microscopic theory of the tunnel junctions with small capacitance (the latter theory takes into account the shot noise as well). The ultimate "output" sensitivity ε_{V}=/2L\Deltaf is shown to be substantially less than the Planck's constant h, for the both types of SQUIDs. This result does not contradict to the uncertainty principle, because the "total" sensitivity ε=(ε_{V}ε_{I}-εmin{IV}\max{2})^{1/2} rather than ε_{V} is an adequate figure of merit of SQUID as a linear amplifier. The total sensitivity is shown to be, in fact, limited by the quantum fluctuations, ε>h/2. These fluctuations originate in the shunting resistances of the dc SQUID, while in the ac SQUID they are due to quantum noise of the following stage of amplification. Nevertheless, even the total sensitivity ε can be made less than h/2, if the "degenerate" type of SQUID is used, being sensitive to the only one of the quadrature components of the input signal.

DOI
10.1109/tmag.1983.1062489

Related papers

Quantum noise in Josephson-junction parametric amplifiers

L. S. Kuzmin, K. K. Likharev, V. V. Migulin +1 more

Crossover between thermal and quantum noise in the externally-pumped Josephson-junction parametric amplifiers is theoretically followed. Two different approaches are used for the analysis : i. Josephson junction is replaced with its RSJ model with the equilibrium source of fluctuations; ii. microscopic theory of the tunnel junctions is used, which takes into account not only thermal and quantum but also shot noise. Because of inconvenience of the noise temperature TNfor the amplifier sensitivity characterization in the quantum limit, we express our results in terms of the figure ΘNwhich is essentially the amplifier output noise energy, reduced to its input (in the classical limit,\Theta_{N}=k_{B}T_{N}). For the nondegenerate amplifier, the minimum value of ΘN. equals hω/2 and is due to quantum noise (zero-point oscillations) in the idle-frequency resonator of the amplifier. For the degenerate amplifier, sensitive to only one quadrature component of the input signal, ΘNcan be made much less than the above "quantum limit" even at operation temperatures much higher thanh\omega/k_{B}, if the Josephson junction characteristic frequency ωcis high enough,h\omega_{c}\gsimk_{B}T. Our analysis of the experimental situatlon shows that the values\Theta_{N}<h\omega/2can be achieved using two-dimensional arrays of a large number (N\simeq100) single-tunnel-junction interferometers with low inductances, inductively coupled to a microwave cavity.

IEEE Transactions on Magnetics•May 1, 1983•9 citations

The dc SQUID near the quantum noise limit

D. J. VanHarlingen, R. H. Koch, Jim A. Clarke

A series of dc SQUIDs has been fabricated in an attempt to obtain quantum-limited sensitivity. Typically, the SQUID inductance, L, is 2 pH, the capacitance and critical current of each tunnel junction are 0.5 pF and 0.5 mA, and the shunt resistance for each junction is 1Ω. The measured spectral density of the voltage noise Sv contains a l/f component that extends typically to 100 kHz or higher. When the l/f component is subtracted out, the best energy sensitivity achieved to date is ε1Hz = Sv2L(θVθΦ)2 less than or approximately equal to 2h, where θV/θΦ PHI is the transfer coefficient.

•Jan 1, 1981•0 citations

Uncertainty principle limit to the energy sensitivity of SQUID’s and other linear amplifiers

Richard F. Voss

SQUID’s (Superconducting quantum interference devices) and other amplifiers are modeled by ideal noiseless linear amplifiers with current in and voltage en noise sources in their input circuits. For independent sources at frequency v the uncertainty principle requires that (e2ni2n)1/2 ≳2hv, where h is Planck’s constant. This limits the intrinsic energy sensitivity ε=Φ2n/2L of a SQUID of inductance L and effective flux noise power Φ2n to ε≳εmin=(e2ni2n)1/2 /2πν=h/π. Correlation of the noise sources or mismatch of the SQUID inductance is shown to degrade εmin.

Applied Physics Letters•Feb 1, 1981•17 citations

Advances in SQUID magnetometers

John L. Clarke

The operation and noise limitations of de and RF SQUID's are outlined, and recent advances in their sensitivity are discussed. A model of the dc SQUID predicts an energy noise level per hertz referred to the SQUID of approximately8 k_{B}TL/R \approx 8 k_{B}T(\piLC)^{1/2}, whereL, R,andCare the SQUID inductance and the shunt resistance and capacitance of each Josephson junction. Some examples of dc SQUID's are described to show that their performance is generally in reasonable agreement with the model. The noise energy has improved from about 2 × 10-30J. Hz-1for a device withL = 1nH and a tunnel junction area of 104µm2to about 2 × 10-33J . Hz-1for a device withL = 0.1nH and a microbridge resistance of 40 Ω. Further improvements axe expected in the near future. The model of the RF SQUID predicts a noise energy per hertz referred to the SQUID of[(\pi\alpha^{2}\phi\min{0}\max{2}/2L) + 2 \pi \alpha k_{B}T\min{a}\max{(eff)}]/\omega_{RF}, where α is the intrinsic width of the distribution of flux transitions,T\min{a}\max{(eff)}is an effective amplifier noise temperature, and ωRFis the pump frequency. With one exception, the performance of the seven types of RF SQUID listed is in reasonable agreement with the model. The noise energy ranges from about 1.5 × 10-29J . Hz-1for a 20-MHz toroidal SQUID to 3.5 × 10-31J . Hz-1for 9-GHz reentrant toroidal SQUID; a somewhat better sensitivity has been reported for a 430-MHz device, apparently in conflict with the theory. In both dc and RF SQUID's, 1/fnoise (fis frequency) is likely to extend to higher frequencies as the white-noise level is decreased.

IEEE Transactions on Electron Devices•Oct 1, 1980•88 citations

Quantum noise theory for the dc SQUID

R. H. Koch, Dale J. Van Harlingen, John L. Clarke

The noise temperature of a dc superconducting quantum interference device (SQUID) coupled to a tuned input circuit is computed using the complete quantum expression for the equilibrium noise in the shunt resistance of each junction. At T = 0, where the noise reduces to zero-point fluctuations, the noise temperature for an optimized system is hn/kB ln2, where n is the signal frequency. The computation is extended to nonzero temperatures, and it is shown that a SQUID operated at 1K can approach the quantum limit.

Applied Physics Letters•Mar 1, 1981•93 citations

Influence of the Josephson junction on the impedance and noise of a resistive superconductive quantum interference device

Robert J. Soulen, William E. Fogle, Jack H. Colwell +2 more

The impedance and noise of a resistive superconductive quantum interference device (R-SQUID) have been measured as a function of the dc and rf currents applied to it. The Josephson junction was adjustable so that data were also taken for several values of the junction critical current. The results were compared with the predictions of a resistively shunted junction (RSJ) model which takes into account the influence of the Josephson junction on the impedance and noise. The agreement was found to be quite good and demonstrates that the noise in the circuit is well understood. Use of the R-SQUID as a noise thermometer below 1 K is assessed in terms of corrections due to the RSJ model. It is demonstrated how the dc and rf currents may be adjusted so that the total noise of the R-SQUID is reduced to within 0.1% of the Johnson noise generated by the resistor alone. Under these conditions, the R-SQUID may be used as a noise thermometer to determine thermodynamic temperature to this inaccuracy from 6 to 700 mK.

Journal of Applied Physics•Oct 15, 1993•4 citations
The sensitivity limitations due to thermal, quantum and shot noise are calculated for dc and ac SQUIDs. Two approximations are used for the Josephson junctions: i. RSJ model with the equilibrium source of thermal-and-quantum fluctuations and ii. microscopic theory of the tunnel junctions with small capacitance (the latter theory takes into account the shot noise as well). The ultimate "output" sensitivity ε_{V}=/2L\Deltaf is shown to be substantially less than the Planck's constant h, for the both types of SQUIDs. This result does not contradict to the uncertainty principle, because the "total" sensitivity ε=(ε_{V}ε_{I}-εmin{IV}\max{2})^{1/2} rather than ε_{V} is an adequate figure of merit of SQUID as a linear amplifier. The total sensitivity is shown to be, in fact, limited by the quantum fluctuations, ε>h/2. These fluctuations originate in the shunting resistances of the dc SQUID, while in the ac SQUID they are due to quantum noise of the following stage of amplification. Nevertheless, even the total sensitivity ε can be made less than h/2, if the "degenerate" type of SQUID is used, being sensitive to the only one of the quadrature components of the input signal.
Crossover between thermal and quantum noise in the externally-pumped Josephson-junction parametric amplifiers is theoretically followed. Two different approaches are used for the analysis : i. Josephson junction is replaced with its RSJ model with the equilibrium source of fluctuations; ii. microscopic theory of the tunnel junctions is used, which takes into account not only thermal and quantum but also shot noise. Because of inconvenience of the noise temperature TNfor the amplifier sensitivity characterization in the quantum limit, we express our results in terms of the figure ΘNwhich is essentially the amplifier output noise energy, reduced to its input (in the classical limit,\Theta_{N}=k_{B}T_{N}). For the nondegenerate amplifier, the minimum value of ΘN. equals hω/2 and is due to quantum noise (zero-point oscillations) in the idle-frequency resonator of the amplifier. For the degenerate amplifier, sensitive to only one quadrature component of the input signal, ΘNcan be made much less than the above "quantum limit" even at operation temperatures much higher thanh\omega/k_{B}, if the Josephson junction characteristic frequency ωcis high enough,h\omega_{c}\gsimk_{B}T. Our analysis of the experimental situatlon shows that the values\Theta_{N}<h\omega/2can be achieved using two-dimensional arrays of a large number (N\simeq100) single-tunnel-junction interferometers with low inductances, inductively coupled to a microwave cavity.
A series of dc SQUIDs has been fabricated in an attempt to obtain quantum-limited sensitivity. Typically, the SQUID inductance, L, is 2 pH, the capacitance and critical current of each tunnel junction are 0.5 pF and 0.5 mA, and the shunt resistance for each junction is 1Ω. The measured spectral density of the voltage noise Sv contains a l/f component that extends typically to 100 kHz or higher. When the l/f component is subtracted out, the best energy sensitivity achieved to date is ε1Hz = Sv2L(θVθΦ)2 less than or approximately equal to 2h, where θV/θΦ PHI is the transfer coefficient.
SQUID’s (Superconducting quantum interference devices) and other amplifiers are modeled by ideal noiseless linear amplifiers with current in and voltage en noise sources in their input circuits. For independent sources at frequency v the uncertainty principle requires that (e2ni2n)1/2 ≳2hv, where h is Planck’s constant. This limits the intrinsic energy sensitivity ε=Φ2n/2L of a SQUID of inductance L and effective flux noise power Φ2n to ε≳εmin=(e2ni2n)1/2 /2πν=h/π. Correlation of the noise sources or mismatch of the SQUID inductance is shown to degrade εmin.
The operation and noise limitations of de and RF SQUID's are outlined, and recent advances in their sensitivity are discussed. A model of the dc SQUID predicts an energy noise level per hertz referred to the SQUID of approximately8 k_{B}TL/R \approx 8 k_{B}T(\piLC)^{1/2}, whereL, R,andCare the SQUID inductance and the shunt resistance and capacitance of each Josephson junction. Some examples of dc SQUID's are described to show that their performance is generally in reasonable agreement with the model. The noise energy has improved from about 2 × 10-30J. Hz-1for a device withL = 1nH and a tunnel junction area of 104µm2to about 2 × 10-33J . Hz-1for a device withL = 0.1nH and a microbridge resistance of 40 Ω. Further improvements axe expected in the near future. The model of the RF SQUID predicts a noise energy per hertz referred to the SQUID of[(\pi\alpha^{2}\phi\min{0}\max{2}/2L) + 2 \pi \alpha k_{B}T\min{a}\max{(eff)}]/\omega_{RF}, where α is the intrinsic width of the distribution of flux transitions,T\min{a}\max{(eff)}is an effective amplifier noise temperature, and ωRFis the pump frequency. With one exception, the performance of the seven types of RF SQUID listed is in reasonable agreement with the model. The noise energy ranges from about 1.5 × 10-29J . Hz-1for a 20-MHz toroidal SQUID to 3.5 × 10-31J . Hz-1for 9-GHz reentrant toroidal SQUID; a somewhat better sensitivity has been reported for a 430-MHz device, apparently in conflict with the theory. In both dc and RF SQUID's, 1/fnoise (fis frequency) is likely to extend to higher frequencies as the white-noise level is decreased.
The noise temperature of a dc superconducting quantum interference device (SQUID) coupled to a tuned input circuit is computed using the complete quantum expression for the equilibrium noise in the shunt resistance of each junction. At T = 0, where the noise reduces to zero-point fluctuations, the noise temperature for an optimized system is hn/kB ln2, where n is the signal frequency. The computation is extended to nonzero temperatures, and it is shown that a SQUID operated at 1K can approach the quantum limit.
The impedance and noise of a resistive superconductive quantum interference device (R-SQUID) have been measured as a function of the dc and rf currents applied to it. The Josephson junction was adjustable so that data were also taken for several values of the junction critical current. The results were compared with the predictions of a resistively shunted junction (RSJ) model which takes into account the influence of the Josephson junction on the impedance and noise. The agreement was found to be quite good and demonstrates that the noise in the circuit is well understood. Use of the R-SQUID as a noise thermometer below 1 K is assessed in terms of corrections due to the RSJ model. It is demonstrated how the dc and rf currents may be adjusted so that the total noise of the R-SQUID is reduced to within 0.1% of the Johnson noise generated by the resistor alone. Under these conditions, the R-SQUID may be used as a noise thermometer to determine thermodynamic temperature to this inaccuracy from 6 to 700 mK.