Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Radiative lifetimes of metastable states of Hg+ and Hg2+

Anthony G. Calamai, Charles E. Johnson

Published Nov 1, 1990• 20 citations
Publisher

Abstract

The natural radiative lifetimes of the 5${\mathit{d}}^{9}$6${\mathit{s}}^{2}$ ${(}^{2}$${\mathit{D}}_{5/2}$ and $^{2}$${\mathit{D}}_{3/2}$) metastable states of ${\mathrm{Hg}}^{+}$ as well as of the 5${\mathit{d}}^{9}$6s${(}^{3}$${\mathit{D}}_{2}$) metastable state of ${\mathrm{Hg}}^{2+}$ have been measured by counting for equal time intervals either the 282-, 198-, or 217-nm photons emitted when the respective metastable ions decay to the ground state. The metastable Hg ions are produced inside a cylindrical electrostatic ion trap by electron bombardment of background Hg vapor maintained at pressures ranging from 4 to 50\ifmmode\times\else\texttimes\fi{}${10}^{\mathrm{\ensuremath{-}}8}$ Torr. The trap consists of a 5.0-cm-diam, 7.5-cm-long cylinder with end caps plus a concentric 0.003-cm-diam central cylinder maintained at a negative potential of 140 V. Following electron impact of the Hg vapor, some of the photons emitted by the decaying metastable ion population are focused onto a narrow-bandwidth interference filter. The photons transmitted by the filter are detected by a photomultiplier tube as a function of time and generate a decay curve. However, the signal detected with the interference filter used to monitor the $^{2}$${\mathit{D}}_{3/2}$ metastable-state population consists of two exponentially decaying components, indicating the presence of another metastable state decaying through the emission of a photon within the bandpass of the filter. The second component is assumed to arise from a cascade originating with the 5${\mathit{d}}^{9}$6s6p (J=9/2) metastable state of ${\mathrm{Hg}}^{+}$. Therefore, as dictated by the composition of the photon decay curve, the pressure-dependent decay rates of the metastable states are obtained from a least-squares fit of either a single- or double-component exponential decay to the natural logarithm of the decay curve.Mean decay rates extrapolated to zero pressure of the background Hg vapor using a straight-line least-squares fit, and the inverse of the zero-pressure intercept yields the natural radiative lifetime of the relevant metastable state. Our results for the lifetimes of the $^{2}$${\mathit{D}}_{5/2}$, $^{2}$${\mathit{D}}_{3/2}$, and J=9/2 metastable states of ${\mathrm{Hg}}^{+}$ are 87\ifmmode\pm\else\textpm\fi{}4, 8.8\ifmmode\pm\else\textpm\fi{}0.4, and 60\ifmmode\pm\else\textpm\fi{}6 msec, respectively, while the lifetime of the ${\mathrm{Hg}}^{2+}$ ${(}^{3}$${\mathit{D}}_{2}$) metastable state is 34\ifmmode\pm\else\textpm\fi{}3 msec.

DOI
10.1103/physreva.42.5425

Related papers

Radiative lifetime of the metastable 1S0 state of Xe2+

K. G. Bhushan, Henrik B. Pedersen, N. Altstein +3 more

The radiative lifetime of the ${}^{1}{S}_{0}$ metastable state of ${\mathrm{Xe}}^{2+}$ has been measured with a different type of electrostatic ion trap. The ion trap stores ion beams of a few keV using purely electrostatic fields and provides a large field-free region where the stored ions oscillate. A photomultiplier working in the single-photon counting mode was used to observe the 380 nm photons arising from the magnetic dipole $(M1)$ transition ${}^{1}{\stackrel{\ensuremath{\rightarrow}}{{S}_{0}}}^{3}{P}_{1}$ of ${\mathrm{Xe}}^{2+}.$ The present measurement yields a value of $4.46\ifmmode\pm\else\textpm\fi{}0.08 \mathrm{ms},$ which is in good agreement with previous measurements, but is almost four times more accurate.

Physical Review A•Jun 8, 2000•30 citations

Lifetime measurement of the metastable 4dD5∕22 state in Sr+88 using a single trapped ion

V. Letchumanan, M. A. Wilson, Patrick Robert Gill +1 more

The natural lifetime of the metastable $4d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}$ state in $^{88}\mathrm{Sr}^{+}$ has been measured using a single laser-cooled, trapped ion. The ion was prepared in the $4d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}$ state by laser excitation of the $5s\phantom{\rule{0.2em}{0ex}}^{2}S_{1∕2}\ensuremath{-}4d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}$ quadrupole transition at 674 nm. The decay time was measured by using Dehmelt's electron shelving method to monitor the ion's electronic state. Two separate investigations were conducted under slightly different experimental conditions. 160 000 decay times from the $4d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}$ state were observed in total, and two different methods for determining the statistical value of the measured lifetime have been compared. Systematic effects have also been estimated, and including these effects yields a value of $\ensuremath{\tau}=390.8(1.6)\phantom{\rule{0.3em}{0ex}}\mathrm{ms}$ ($1\ensuremath{\sigma}$ uncertainty) for the natural lifetime.

Physical Review A•Jul 13, 2005•39 citations

Radiative Lifetime of the 2 S01 Metastable State of Helium

Robert S. Van Dyck, C. E. Johnson, Howard A. Shugart

A time-of-flight technique has been used to measure the radiative lifetime of the $2 ^{1}S_{0}$ state of helium. After passing from a cooled source, helium atoms are excited by a pulsed anti-parallel electron beam. The atomic beam then contains not only ground-state helium atoms but also metastable atoms in both the $2 ^{3}S_{1}$ and the $2 ^{1}S_{0}$ states. The metastable atoms are detected at two positions, 1.9 and 6.7 m from the electron gun, by Auger ejection of an electron from a copper target, the first of which is a 60% transmitting mesh. Ground-state helium atoms cannot cause an electron to be ejected and hence are not detected. The time-of-flight distribution for the metastable $2 ^{1}S_{0}$ state is separated from that of the $2 ^{3}S_{1}$ state by illuminating the beam with an rf-discharge helium lamp. The $2 ^{1}S_{0}$ state is quenched by resonant absorption of a 20 581 - \AA{}A photon, raising the atom to the $2 ^{1}P_{1}$ state, which then decays preferentially to the $^{1}S_{0}$ ground state; the $2 ^{3}S_{1}$ state remains unaffected because it is the ground state for the triplet system. The time-of-flight distribution for the $2 ^{1}S_{0}$ atoms is therefore obtained from the difference between the full beam and the quenched beam. A comparison of the number of $2 ^{1}S_{0}$ metastables within a given velocity interval at the two detectors determines the number which decay in flight and yields a value for the two-photon radiative lifetime. The value of the singlet lifetime for both ${\mathrm{He}}^{3}$ and ${\mathrm{He}}^{4}$ is 19.7 \ifmmode\pm\else\textpm\fi{} 1.0 msec, agreeing with the theoretical value of 19.5 msec, but disagreeing with the value 38 \ifmmode\pm\else\textpm\fi{} 8 msec measured by Pearl using a movable detector. The 1.0-msec error is an estimate of the remaining systematic errors in the experiment.

Physical Review A•Oct 1, 1971•99 citations

Radiative lifetime of metastable 2S13 Li+

Randall D. Knight, Michael H. Prior

The radiative lifetime of $1s2s^{3}S_{1}$ ${\mathrm{Li}}^{+}$ ions has been measured by a comparison of the count rate of spontaneous decay photons (210 \AA{}) to a laser-induced fluorescence signal proportional to the total number of metastable ions. The ions were confined in a rf-quadrupole trap, and the fluorescence signal used was the intercombination transition $1s2p^{3}P_{1}$ to $1{s}^{2}^{1}S_{0}$ at 202 \AA{}. The $^{3}P_{1}$ state was populated from $^{3}S_{1}$ by absorption of laser photons at 5485 \AA{}. The result is ${\ensuremath{\tau}}_{r}=58.6\ifmmode\pm\else\textpm\fi{}12.9$ sec (95% confidence level); theory predicts ${\ensuremath{\tau}}_{r}=49.1$ sec.

Physical Review A•Jan 1, 1980•50 citations

Radiative Lifetime Measurement of the Ba+ Metastable D3/2 State

Nan Yu, Warren Nagourney, HANS G. DEHMELT

The extremely long lifetimes of the metastable $D$ states of the ${\mathrm{Ba}}^{+}$ ion make it difficult to measure them accurately due to their high sensitivity to collisional effects. Thus a discrepancy exists between theories and experiments for the ${\mathrm{Ba}}^{+}$ ${D}_{3/2}$ state. We have measured the ${D}_{3/2}$ lifetime under a nearly ideal condition, i.e., single trapped ${\mathrm{Ba}}^{+}$ ions in ultrahigh vacuum. The obtained value of $79.8\ifmmode\pm\else\textpm\fi{}4.6\mathrm{s}$ resolves the existing discrepancy. The collisional quenching is found insignificant in our experiment, but there are indications of a non-negligible fine-structure mixing effect.

Physical Review Letters•Jun 30, 1997•65 citations

Lifetime measurements of the 4f145d metastable states in single ytterbium ions

Nan Yu, Lute Maleki

The ytterbium ion has a rich level structure of low-lying states, and is one of the most widely used in experiments with trapped ions. We have measured the radiative lifetimes for the two ${4f}^{14}5d$ metastable states using single ytterbium ions confined in a rf trap. The obtained lifetimes for ${D}_{3/2}$ and ${D}_{5/2}$ states are 52.7(2.4) and 7.0(0.4) ms, respectively. The results are in good agreement with previously measured values, but differ significantly from theoretical estimates. The ${P}_{1/2}$ branching ratio into ${D}_{3/2}$ has also been obtained from the experiment to be 0.0483 with a 9% uncertainty.

Physical Review A•Jan 12, 2000•58 citations
The natural radiative lifetimes of the 5d9{\mathit{d}}^{9}d96s2{\mathit{s}}^{2}s2 {(}^{2}$${\mathit{D}}_{5/2} and ^{2}$${\mathit{D}}_{3/2}) metastable states of Hg+{\mathrm{Hg}}^{+}Hg+ as well as of the 5d9{\mathit{d}}^{9}d96s{(}^{3}$${\mathit{D}}_{2}) metastable state of Hg2+{\mathrm{Hg}}^{2+}Hg2+ have been measured by counting for equal time intervals either the 282-, 198-, or 217-nm photons emitted when the respective metastable ions decay to the ground state. The metastable Hg ions are produced inside a cylindrical electrostatic ion trap by electron bombardment of background Hg vapor maintained at pressures ranging from 4 to 50\ifmmode\times\else\texttimes\fi{}10\ensuremath−8{10}^{\mathrm{\ensuremath{-}}8}10\ensuremath−8 Torr. The trap consists of a 5.0-cm-diam, 7.5-cm-long cylinder with end caps plus a concentric 0.003-cm-diam central cylinder maintained at a negative potential of 140 V. Following electron impact of the Hg vapor, some of the photons emitted by the decaying metastable ion population are focused onto a narrow-bandwidth interference filter. The photons transmitted by the filter are detected by a photomultiplier tube as a function of time and generate a decay curve. However, the signal detected with the interference filter used to monitor the ^{2}$${\mathit{D}}_{3/2} metastable-state population consists of two exponentially decaying components, indicating the presence of another metastable state decaying through the emission of a photon within the bandpass of the filter. The second component is assumed to arise from a cascade originating with the 5d9{\mathit{d}}^{9}d96s6p (J=9/2) metastable state of Hg+{\mathrm{Hg}}^{+}Hg+. Therefore, as dictated by the composition of the photon decay curve, the pressure-dependent decay rates of the metastable states are obtained from a least-squares fit of either a single- or double-component exponential decay to the natural logarithm of the decay curve.Mean decay rates extrapolated to zero pressure of the background Hg vapor using a straight-line least-squares fit, and the inverse of the zero-pressure intercept yields the natural radiative lifetime of the relevant metastable state. Our results for the lifetimes of the ^{2}$${\mathit{D}}_{5/2}, ^{2}$${\mathit{D}}_{3/2}, and J=9/2 metastable states of Hg+{\mathrm{Hg}}^{+}Hg+ are 87\ifmmode\pm\else\textpm\fi{}4, 8.8\ifmmode\pm\else\textpm\fi{}0.4, and 60\ifmmode\pm\else\textpm\fi{}6 msec, respectively, while the lifetime of the Hg2+{\mathrm{Hg}}^{2+}Hg2+ {(}^{3}$${\mathit{D}}_{2}) metastable state is 34\ifmmode\pm\else\textpm\fi{}3 msec.
The radiative lifetime of the 1S0{}^{1}{S}_{0}1S0​ metastable state of Xe2+{\mathrm{Xe}}^{2+}Xe2+ has been measured with a different type of electrostatic ion trap. The ion trap stores ion beams of a few keV using purely electrostatic fields and provides a large field-free region where the stored ions oscillate. A photomultiplier working in the single-photon counting mode was used to observe the 380 nm photons arising from the magnetic dipole (M1)(M1)(M1) transition ${}^{1}{\stackrel{\ensuremath{\rightarrow}}{{S}_{0}}}^{3}{P}_{1}$ of Xe2+.{\mathrm{Xe}}^{2+}.Xe2+. The present measurement yields a value of $4.46\ifmmode\pm\else\textpm\fi{}0.08 \mathrm{ms},$ which is in good agreement with previous measurements, but is almost four times more accurate.
The natural lifetime of the metastable 4d2D5∕24d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}4d2D5∕2​ state in 88Sr+^{88}\mathrm{Sr}^{+}88Sr+ has been measured using a single laser-cooled, trapped ion. The ion was prepared in the 4d2D5∕24d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}4d2D5∕2​ state by laser excitation of the $5s\phantom{\rule{0.2em}{0ex}}^{2}S_{1∕2}\ensuremath{-}4d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}$ quadrupole transition at 674 nm. The decay time was measured by using Dehmelt's electron shelving method to monitor the ion's electronic state. Two separate investigations were conducted under slightly different experimental conditions. 160 000 decay times from the 4d2D5∕24d\phantom{\rule{0.2em}{0ex}}^{2}D_{5∕2}4d2D5∕2​ state were observed in total, and two different methods for determining the statistical value of the measured lifetime have been compared. Systematic effects have also been estimated, and including these effects yields a value of $\ensuremath{\tau}=390.8(1.6)\phantom{\rule{0.3em}{0ex}}\mathrm{ms}$ ($1\ensuremath{\sigma}$ uncertainty) for the natural lifetime.
A time-of-flight technique has been used to measure the radiative lifetime of the 21S02 ^{1}S_{0}21S0​ state of helium. After passing from a cooled source, helium atoms are excited by a pulsed anti-parallel electron beam. The atomic beam then contains not only ground-state helium atoms but also metastable atoms in both the 23S12 ^{3}S_{1}23S1​ and the 21S02 ^{1}S_{0}21S0​ states. The metastable atoms are detected at two positions, 1.9 and 6.7 m from the electron gun, by Auger ejection of an electron from a copper target, the first of which is a 60% transmitting mesh. Ground-state helium atoms cannot cause an electron to be ejected and hence are not detected. The time-of-flight distribution for the metastable 21S02 ^{1}S_{0}21S0​ state is separated from that of the 23S12 ^{3}S_{1}23S1​ state by illuminating the beam with an rf-discharge helium lamp. The 21S02 ^{1}S_{0}21S0​ state is quenched by resonant absorption of a 20 581 - \AA{}A photon, raising the atom to the 21P12 ^{1}P_{1}21P1​ state, which then decays preferentially to the 1S0^{1}S_{0}1S0​ ground state; the 23S12 ^{3}S_{1}23S1​ state remains unaffected because it is the ground state for the triplet system. The time-of-flight distribution for the 21S02 ^{1}S_{0}21S0​ atoms is therefore obtained from the difference between the full beam and the quenched beam. A comparison of the number of 21S02 ^{1}S_{0}21S0​ metastables within a given velocity interval at the two detectors determines the number which decay in flight and yields a value for the two-photon radiative lifetime. The value of the singlet lifetime for both He3{\mathrm{He}}^{3}He3 and He4{\mathrm{He}}^{4}He4 is 19.7 \ifmmode\pm\else\textpm\fi{} 1.0 msec, agreeing with the theoretical value of 19.5 msec, but disagreeing with the value 38 \ifmmode\pm\else\textpm\fi{} 8 msec measured by Pearl using a movable detector. The 1.0-msec error is an estimate of the remaining systematic errors in the experiment.
The radiative lifetime of 1s2s3S11s2s^{3}S_{1}1s2s3S1​ Li+{\mathrm{Li}}^{+}Li+ ions has been measured by a comparison of the count rate of spontaneous decay photons (210 \AA{}) to a laser-induced fluorescence signal proportional to the total number of metastable ions. The ions were confined in a rf-quadrupole trap, and the fluorescence signal used was the intercombination transition 1s2p3P11s2p^{3}P_{1}1s2p3P1​ to $1{s}^{2}^{1}S_{0}$ at 202 \AA{}. The 3P1^{3}P_{1}3P1​ state was populated from 3S1^{3}S_{1}3S1​ by absorption of laser photons at 5485 \AA{}. The result is ${\ensuremath{\tau}}_{r}=58.6\ifmmode\pm\else\textpm\fi{}12.9$ sec (95% confidence level); theory predicts ${\ensuremath{\tau}}_{r}=49.1$ sec.
The extremely long lifetimes of the metastable DDD states of the Ba+{\mathrm{Ba}}^{+}Ba+ ion make it difficult to measure them accurately due to their high sensitivity to collisional effects. Thus a discrepancy exists between theories and experiments for the Ba+{\mathrm{Ba}}^{+}Ba+ D3/2{D}_{3/2}D3/2​ state. We have measured the D3/2{D}_{3/2}D3/2​ lifetime under a nearly ideal condition, i.e., single trapped Ba+{\mathrm{Ba}}^{+}Ba+ ions in ultrahigh vacuum. The obtained value of $79.8\ifmmode\pm\else\textpm\fi{}4.6\mathrm{s}$ resolves the existing discrepancy. The collisional quenching is found insignificant in our experiment, but there are indications of a non-negligible fine-structure mixing effect.
The ytterbium ion has a rich level structure of low-lying states, and is one of the most widely used in experiments with trapped ions. We have measured the radiative lifetimes for the two 4f145d{4f}^{14}5d4f145d metastable states using single ytterbium ions confined in a rf trap. The obtained lifetimes for D3/2{D}_{3/2}D3/2​ and D5/2{D}_{5/2}D5/2​ states are 52.7(2.4) and 7.0(0.4) ms, respectively. The results are in good agreement with previously measured values, but differ significantly from theoretical estimates. The P1/2{P}_{1/2}P1/2​ branching ratio into D3/2{D}_{3/2}D3/2​ has also been obtained from the experiment to be 0.0483 with a 9% uncertainty.