Conference on Precision Electromagnetic Measurements

Study for a 43Ca+ Optical Frequency Standard

K. Matsubara, Kenji Toyoda, Y. Li, U. Tanaka, S. Uetake, K. Hayasaka, S. Urabe, Mizuhiko Hosokawa

Published Jun 1, 2004• 3 citations
Publisher

Abstract

The authors proceed with a research and development of an optical frequency standard based on the2S1/2-2D5/2transition of43Ca+in a RF trap. For this purpose, motional sidebands of a single40Ca+ion were observed and a stable laser-diode system for spectroscopy of43Ca+are being developed
DOI
10.1109/cpem.2004.305293

Related papers

Single Ca/sup +/ ion trapping toward precise frequency measurement of the 4 /sup 2/S/sub 1/2/ - 3/sup 2/D/sub 5/2/ transition

K. Matsubara, Y. Li, Masatoshi Kajita +3 more

We are proceeding with a development of an optical frequency standard using a2Sfrac12-2D5/2electric quadrupole transition of Ca+ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of-15is attainable in measurement of the2Sfrac12-2D5/2transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single40Ca+ions to the2D5/2state

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 18, 2006•0 citations

Single Ca + Ion Trapping toward Precise Frequency Measurement of the 4 2 S 1/2 - 3 2 D 5/2 Transition

Kouki Matsubara, Y. Li, Masatoshi Kajita +3 more

Abstract —We are proceeding with a development of an optical frequency standard using a 2 S 1/2 – 2 D 5/2 electric quadrupole transition of Ca + ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of <1 x 10 -15 is attainable in measurement of the 2 S 1/2 – 2 D 5/2 transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single 40 Ca + ions to the 2 D 5/2 state. I. I NTRODUCTION The uncertainty of primary frequency standards using Cs atoms reaches around 10 -15 and the inherent limits involved in them are discussed. On the other hand, frequency standards using new materials and methods are proposed for developing more accurate frequency standards. Recently, several groups have measured frequencies of the ionic forbidden transitions in the optical region to apply them to the clock transitions of optical frequency standards [1]. We now proceeds with study on an optical frequency standard using single Ca

•Aug 31, 2005•2 citations

Frequency stability characterisation of a strontium trapped ion optical frequency standard

G. P. Barwood, Patrick Robert Gill, Guozheng Huang +1 more

Two 674-nm optical frequency standards based on the2S1/2-2D5/2transition in88Sr+are under development at NPL. Comparison of the standards allows determination of the frequency stability and reproducibility via difference frequency measurements. A relative frequency stability between the traps of ap3times10-15over a 100 s averaging time has been observed. A compact, transportable system is also being developed, which could find application in ground stations or as an optical frequency clock in space.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

Quadrupole Transition Spectrum Measurement of Single Ca+ Ions Toward Optical Frequency Standards

Kensuke Matsubara, Ying Li, Kyoya Fukuda +6 more

The National Institute of Information and Communications Technology in Japan is proceeding with development of an optical frequency standard using an electric quadrupole transition of Ca+ ions in a small radio-frequency trap. The single, trapped 40Ca+ ions are laser cooled to a temperature of <10 mK using extended-cavity diode lasers at 397 nm and 866 nm. In order to measure the electric quadrupole transition, the linewidth of the clock laser diode at 729 nm is reduced to ~66 Hz using an ultra-low-expansion (ULE) cavity. We observed the electric quadrupole transition with a linewidth of ~600 kHz, together with the ionic motional sidebands. We are also developing optical frequency combs without photonic fibers broadening the spectrum. The experimental is now improved in order to observe the narrower linewidth of the quadrupole transition.

•Dec 9, 2006•0 citations

Spectroscopy of Single Trapped Ions and Application to Frequency Standards

HERBERT WALTHER

Single ions trapped and laser cooled provide ideal objects for high resolution spectroscopy and frequency standards. For the latter purpose we are investigating the 5s2 1S0 → 5s5p 3P0 transition of In+. With a natural linewidth of only 1.1 Hz this resonance offers very high resolution and is highly immune to frequency shifts due to external electromagnetic fields, because it connects two levels with vanishing electronic magnetic momenta [1]. The wavelength of this clock transition is 236.5 nm and is technically very convenient, since it coincides with the fourth harmonic of the 946 nm Nd:YAG laser line. So this intrinsically frequency stable solid-state laser can be used to excite the transition [2]. For laser cooling and fluorescence detection of the indium ion the 5s2 1So -> 5s5p 3P1 transition at 230.6 nm can be employed. The use of the relatively narrow intercombination line for laser cooling allows us to study optical sideband cooling in the strong binding regime, where the oscillation frequencies of the ion in the trap (around 1 MHz) are larger than the optical linewidth of 360 kHz. In this parameter range laser cooling is possible to the quantum ground state of the vibrational motion in the trap corresponding to a temperature of roughly 100 μK. The same low temperature was obtained with sideband cooling of a small Coulomb crystal consisting of two ions, creating an interesting new quantum few-particle system.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jan 1, 1998•0 citations

High-resolution spectroscopy of the88Sr+single ion optical frequency standard

P. Dubé, Alan A. Madej, J. E. Bernard +1 more

The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Aug 29, 2007•8 citations
Abstract —We are proceeding with a development of an optical frequency standard using a 2 S 1/2 – 2 D 5/2 electric quadrupole transition of Ca + ions in a small radio-frequency trap. We have theoretically confirmed that an uncertainty of <1 x 10 -15 is attainable in measurement of the 2 S 1/2 – 2 D 5/2 transition frequency. Experimentally, we have developed stable laser-diode systems and observed the quantum jump of single 40 Ca + ions to the 2 D 5/2 state. I. I NTRODUCTION The uncertainty of primary frequency standards using Cs atoms reaches around 10 -15 and the inherent limits involved in them are discussed. On the other hand, frequency standards using new materials and methods are proposed for developing more accurate frequency standards. Recently, several groups have measured frequencies of the ionic forbidden transitions in the optical region to apply them to the clock transitions of optical frequency standards [1]. We now proceeds with study on an optical frequency standard using single Ca
Two 674-nm optical frequency standards based on the2S1/2-2D5/2transition in88Sr+are under development at NPL. Comparison of the standards allows determination of the frequency stability and reproducibility via difference frequency measurements. A relative frequency stability between the traps of ap3times10-15over a 100 s averaging time has been observed. A compact, transportable system is also being developed, which could find application in ground stations or as an optical frequency clock in space.
The National Institute of Information and Communications Technology in Japan is proceeding with development of an optical frequency standard using an electric quadrupole transition of Ca+ ions in a small radio-frequency trap. The single, trapped 40Ca+ ions are laser cooled to a temperature of <10 mK using extended-cavity diode lasers at 397 nm and 866 nm. In order to measure the electric quadrupole transition, the linewidth of the clock laser diode at 729 nm is reduced to ~66 Hz using an ultra-low-expansion (ULE) cavity. We observed the electric quadrupole transition with a linewidth of ~600 kHz, together with the ionic motional sidebands. We are also developing optical frequency combs without photonic fibers broadening the spectrum. The experimental is now improved in order to observe the narrower linewidth of the quadrupole transition.
Single ions trapped and laser cooled provide ideal objects for high resolution spectroscopy and frequency standards. For the latter purpose we are investigating the 5s2 1S0 → 5s5p 3P0 transition of In+. With a natural linewidth of only 1.1 Hz this resonance offers very high resolution and is highly immune to frequency shifts due to external electromagnetic fields, because it connects two levels with vanishing electronic magnetic momenta [1]. The wavelength of this clock transition is 236.5 nm and is technically very convenient, since it coincides with the fourth harmonic of the 946 nm Nd:YAG laser line. So this intrinsically frequency stable solid-state laser can be used to excite the transition [2]. For laser cooling and fluorescence detection of the indium ion the 5s2 1So -> 5s5p 3P1 transition at 230.6 nm can be employed. The use of the relatively narrow intercombination line for laser cooling allows us to study optical sideband cooling in the strong binding regime, where the oscillation frequencies of the ion in the trap (around 1 MHz) are larger than the optical linewidth of 360 kHz. In this parameter range laser cooling is possible to the quantum ground state of the vibrational motion in the trap corresponding to a temperature of roughly 100 μK. The same low temperature was obtained with sideband cooling of a small Coulomb crystal consisting of two ions, creating an interesting new quantum few-particle system.
The present decade has seen great advances in optical frequency standards following the development of femtosecond laser frequency combs. With this technology, combined with a stable and narrow probe laser source (50-100 Hz linewidth), we made a systematic study of the 5s 2S1/2-4d 2D5/2 (S-D) transition frequency of the 88Sr+ ion as a function of the quantization axis in the trap. This study revealed the presence of systematic shifts caused by residual micromotion in our rf Paul trap and led to an evaluation of those shifts. Also, a method was developed based on the measurement of the Zeeman spectrum of the clock transition to cancel the electric quadrupole shift caused by patch potentials on the trap electrodes. From these results, we also determined the absolute frequency of the S-D clock transition frequency at 674 nm with a fractional frequency uncertainty of 3.4 × 10-14. We have since made improvements to our probe laser system and have observed 5 Hz Fourier transform limited linewidths on a Zeeman component of the S-D transition of the 88Sr+ ion. To observe such a narrow transition it is essential to have a known and well behaved drift of the laser frequency during the few minutes it takes to measure the ion resonance using the quantum jump signal. Our approach to minimize the drift rate and its sensitivity to temperature fluctuations has been to stabilize the cavity at the temperature where its coefficient of thermal expansion is zero. We will present an overview of our recent progress made on the frequency standard based on the laser-cooled and trapped single ion of 88Sr+.