Conference on Precision Electromagnetic Measurements

Programmable Josephson Voltage Standard as a Stable Reference Source of High Current Capability

Kyu-Tae Kim, Mun-Seog Kim, Seog‐Tae Han, Myung Kyun Kim

Published Jun 1, 2004• 1 citation
Publisher

Abstract

The programmable Josephson voltage standard combined with additional variable current source is proposed to be used as an ideal reference source. A stable reference source with sufficient current capability is required for low resistance ratio measurement, for example. Owing to the large Shapiro step of the PJVS array, a simple current source easily available with medium stability is sufficient for this purpose. Experimental result will also be presented to support the proposed idea

DOI
10.1109/cpem.2004.305599

Related papers

Design and Implementation of a Multichannel Current Bias Power Supply for Programmable Josephson Voltage Standard

Ming Ding, Dong Li, Qiuyu Xu +1 more

The Programmable Josephson Voltage Standard (PJVS) is a benchmark device based on the Josephson effect, and capable of outputting a series of high-precision DC or stepped sinusoidal voltages on demand. Combined with differential sampling techniques, the PJVS holds broad application prospects in the field of precision voltage measurement. The bias power supply is a core component of the PJVS. By controlling the magnitudes of bias currents across each segment of the Josephson junction array, the state of the Shapiro steps of each segment is regulated independently. This ultimately combines to output a programmable, precise quantum voltage. A current-type bias power supply scheme for the PJVS system is proposed, based on the negative feedback principle, and the hardware circuitry for a multi-channel current bias power supply is developed. To enhance the transient and steady-state performance of the current bias power supply, this study employs high-speed bipolar digital-to-analogue converters and high-bandwidth negative feedback loop technology to develop an independently programmable multi-channel low-noise current bias power supply. To address the issue of hardware interface resource allocation for a multi-channel current bias power supply, the hardware circuit employs an SPI communication wiring multiplexing strategy. To address the challenge of synchronizing multiple channels. The software program utilizes an interactive approach between the write and refresh modules to control DAC outputs. This achieves a hybrid mechanism combining parallel and serial multi-channel control. Stability testing for a 10 Ω load yields an average short-term stability of 400 nA / min. The multi-channel current bias power supply fulfils the experimental specifications of the PJVS system.

Journal of Physics Conference Series•Mar 1, 2026•0 citations

Demonstration of a 10 V programmable Josephson voltage standard system based on a multi-chip technique

Tatsuji Yamada, Hajime SASAKI, Hirotake Yamamori +1 more

We have demonstrated a programmable Josephson voltage standard (PJVS) operation up to 10.84 V using a multi-chip technique. We combined two PJVS chips fabricated using NbN/(TiN x /NbN) 2 junction technology. Each PJVS chip was mounted on a single chip carrier using bonding wire, and the two chip carriers were connected by a simple Cu lead wire, and mounted on a cryocooler. High-precision measurements confirmed flat voltage steps for all 22 cells, with a peak-to-peak variation of 100 nV and wide margins of at least 0.35 mA. We also confirmed the stability of the voltage steps in spite of a temperature and RF frequency variation of ± 0.1 K and ± 0.1 GHz, respectively.

Superconductor Science and Technology•Feb 1, 2008•15 citations

Josephson-based quantum voltage standards – an ongoing success story

Ralf Behr, Stephan Bauer, Marco Kraus +2 more

The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.

•Jan 1, 2025•0 citations

A 10 V programmable Josephson voltage standard circuit with a maximum output voltage of 20 V

Hirotake Yamamori, Takahiro Yamada, Hitoshi Sasaki +1 more

A 10 V programmable Josephson voltage standard (PJVS) circuit with a maximum output voltage of 20 V and a microwave bias of 18.5 GHz was designed and fabricated. Although an attempt was made to improve the fabrication yield for the 10 V PJVS circuit, it was not sufficiently large to reproducibly fabricate a perfect chip without any defects. The redundant arrays were additionally integrated to increase the maximum output voltage, which contributed to an increase in the number of available chips under the limited fabrication yield. Fortunately, most of the defective arrays had a zeroth Shapiro step, while the first step was very small or zero. If the array was not dc biased, it did not generate any voltage, because it worked as a superconductive wiring. In this case, the maximum output voltage became smaller than that of a perfect chip, but it functioned as a 10 V PJVS, due to the back-up arrays.

Superconductor Science and Technology•Jul 23, 2008•62 citations

Feasibility of the Josephson voltage and current standards on a single chip

Rais S. Shaikhaidarov, Ilya Antonov, Kyung Ho Kim +5 more

The quantum Josephson voltage standard is well established across the metrology community for many years. It relies on the synchronization of the flux tunneling in the S/I/S Josephson junctions (JJ) with the microwave radiation (MW) of frequency f such that V=Φ0fm, where m = 0, 1, 2, …. The phenomenon is called the Shapiro steps. Together with the quantum Hall resistance standard, the voltage standard forms the foundation of electrostatic metrology. The current is then defined as the ratio of the voltage and resistance. Realization of the quantum current standard would close the electrostatic metrological triangle of voltage–resistance–current. The current quantization I=2efm, the inverse Shapiro steps, was recently shown using the superconducting nanowires and small JJ. The effect is a synchronization of the MW with the Cooper pair tunneling. This paves the way to combine the JJ voltage and current standards on the same chip and demonstrate feasibility of the multi-standard operation. We show the voltage and current quantization on the same chip up to frequency of 10 GHz, corresponding to the amplitudes ∼ 20.67 μV and ∼ 3.2 nA, respectively. The accuracy of the voltage and current quantization, however, is relatively low, 35 and 100 ppk, respectively. We discuss measures to optimize the JJs, circuit, and environment to boost the amplitude and accuracy of the standards.

arXiv:2410.11018•Applied Physics Letters•Sep 16, 2024•7 citations

Computer-Controlled operation of PTB’s 80 V Programmable Josephson Voltage Standard

L. Palafox, Ralf Behr

After the proof of principle presented at the last CPEM, PTB’s 80 V Programmable Josephson Voltage Standard (PJVS) has been extended with a computer controlled bias source. This paper presents the development of a computer-controlled bias source for this PJVS. The compact 80 V PJVS can then be integrated into experimental setups like Penning trap experiments at the Max-Planck-Institute for Nuclear Physics.

Conference on Precision Electromagnetic Measurements•Jul 8, 2024•3 citations
The programmable Josephson voltage standard combined with additional variable current source is proposed to be used as an ideal reference source. A stable reference source with sufficient current capability is required for low resistance ratio measurement, for example. Owing to the large Shapiro step of the PJVS array, a simple current source easily available with medium stability is sufficient for this purpose. Experimental result will also be presented to support the proposed idea
The Programmable Josephson Voltage Standard (PJVS) is a benchmark device based on the Josephson effect, and capable of outputting a series of high-precision DC or stepped sinusoidal voltages on demand. Combined with differential sampling techniques, the PJVS holds broad application prospects in the field of precision voltage measurement. The bias power supply is a core component of the PJVS. By controlling the magnitudes of bias currents across each segment of the Josephson junction array, the state of the Shapiro steps of each segment is regulated independently. This ultimately combines to output a programmable, precise quantum voltage. A current-type bias power supply scheme for the PJVS system is proposed, based on the negative feedback principle, and the hardware circuitry for a multi-channel current bias power supply is developed. To enhance the transient and steady-state performance of the current bias power supply, this study employs high-speed bipolar digital-to-analogue converters and high-bandwidth negative feedback loop technology to develop an independently programmable multi-channel low-noise current bias power supply. To address the issue of hardware interface resource allocation for a multi-channel current bias power supply, the hardware circuit employs an SPI communication wiring multiplexing strategy. To address the challenge of synchronizing multiple channels. The software program utilizes an interactive approach between the write and refresh modules to control DAC outputs. This achieves a hybrid mechanism combining parallel and serial multi-channel control. Stability testing for a 10 Ω load yields an average short-term stability of 400 nA / min. The multi-channel current bias power supply fulfils the experimental specifications of the PJVS system.
We have demonstrated a programmable Josephson voltage standard (PJVS) operation up to 10.84 V using a multi-chip technique. We combined two PJVS chips fabricated using NbN/(TiN x /NbN) 2 junction technology. Each PJVS chip was mounted on a single chip carrier using bonding wire, and the two chip carriers were connected by a simple Cu lead wire, and mounted on a cryocooler. High-precision measurements confirmed flat voltage steps for all 22 cells, with a peak-to-peak variation of 100 nV and wide margins of at least 0.35 mA. We also confirmed the stability of the voltage steps in spite of a temperature and RF frequency variation of ± 0.1 K and ± 0.1 GHz, respectively.
The past few decades have witnessed great progress being made from the first voltage standards based on arrays of Josephson junctions. Continuous improvements in the fabrication process have increased the quality and “user-friendliness” of these superconducting circuits. Combined with the improvements in measuring electronics, the range of applications of Josephson-based measurements with unmatched precision has extended from DC into AC voltage metrology for signal frequencies up to 500 kHz. In this poster we will present several Josephson-based measurement systems developed for metrology applications. Two versions of quantum AC standards will be used as Josephson references: Programmable Josephson Voltage Standards (PJVS), which are based on serial arrays with up to 300,000 Josephson junctions, and pulse-driven arrays with more than 50,000 junctions, typically referred to as Josephson Arbitrary Waveform Synthesizers (JAWS). PJVS can reach amplitudes of up to 80 V, while pulse-driven arrays can reach up to 1 V or even 4 V. The advantage of pulse-driven Josephson voltage standards is that they are ideally suited as quantum-based voltage synthesizers for arbitrary waveforms or sine waves with high spectral purity. Therefore, they can be used directly to characterize or calibrate ADCs. In addition, JAWS are particularly useful in Josephson impedance bridges, which perform automated impedance calibrations at the 10-9 uncertainty level over a wide frequency range from 50 Hz to 80 kHz in a single bridge. We will further show how PJVS are used in commercial quantum voltmeters for DC and AC voltages and are typically used as quantum voltage references in measurement systems. Using differential sampling based on PJVS, uncertainties at the level of a few parts in 108 for frequencies up to the kHz range can be achieved. Such quantum-based AC voltage calibrations are at least 30 times faster than conventional AC-DC transfer and offer even better uncertainties. This idea has been quickly adopted by many National Metrology Institutes to establish such systems for AC voltage calibrations. As an example, the BIPM will now start worldwide onsite comparisons to ensure the uniformity of the new method which we introduced in 2006. But developments continue. Recently, a sub-sampling technique was used to extend the frequency range of the AC quantum voltmeter to up to 100 kHz with uncertainties below 5 parts in 106. In addition, a novel method, also for differential sampling, enables the measurement of arbitrary waveforms and the calibration of specific tones. Our poster will provide an overview of these Josephson-based metrological applications and present the latest developments from this fast-developing area.
A 10 V programmable Josephson voltage standard (PJVS) circuit with a maximum output voltage of 20 V and a microwave bias of 18.5 GHz was designed and fabricated. Although an attempt was made to improve the fabrication yield for the 10 V PJVS circuit, it was not sufficiently large to reproducibly fabricate a perfect chip without any defects. The redundant arrays were additionally integrated to increase the maximum output voltage, which contributed to an increase in the number of available chips under the limited fabrication yield. Fortunately, most of the defective arrays had a zeroth Shapiro step, while the first step was very small or zero. If the array was not dc biased, it did not generate any voltage, because it worked as a superconductive wiring. In this case, the maximum output voltage became smaller than that of a perfect chip, but it functioned as a 10 V PJVS, due to the back-up arrays.
The quantum Josephson voltage standard is well established across the metrology community for many years. It relies on the synchronization of the flux tunneling in the S/I/S Josephson junctions (JJ) with the microwave radiation (MW) of frequency f such that V=Φ0fm, where m = 0, 1, 2, …. The phenomenon is called the Shapiro steps. Together with the quantum Hall resistance standard, the voltage standard forms the foundation of electrostatic metrology. The current is then defined as the ratio of the voltage and resistance. Realization of the quantum current standard would close the electrostatic metrological triangle of voltage–resistance–current. The current quantization I=2efm, the inverse Shapiro steps, was recently shown using the superconducting nanowires and small JJ. The effect is a synchronization of the MW with the Cooper pair tunneling. This paves the way to combine the JJ voltage and current standards on the same chip and demonstrate feasibility of the multi-standard operation. We show the voltage and current quantization on the same chip up to frequency of 10 GHz, corresponding to the amplitudes ∼ 20.67 μV and ∼ 3.2 nA, respectively. The accuracy of the voltage and current quantization, however, is relatively low, 35 and 100 ppk, respectively. We discuss measures to optimize the JJs, circuit, and environment to boost the amplitude and accuracy of the standards.