Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics Letters A

Sensitivity of intensity and transmission fluctuations in light scattering to frequency, absorption and impurity configuration

Michael J. Stephen

Published Mar 1, 1988• 12 citations
Publisher
DOI
10.1016/0375-9601(88)90588-9

Related papers

Intensity Effects in Resonance Light Scattering

B. R. Mollow

Springer eBooks•Jan 1, 1979•0 citations

Observation of long range intensity correlation in the transport of coherent light through a random medium

Meint P. van Albada, Johannes F. de Boer, Ad Lagendijk

We report experimental proof for the buildup of long range intensity correlations in the multiple scattering of classical waves, on the basis of a study of frequency-dependent intensity fluctuations in the transmitted wave, in experiments where coherent light is scattered by slabs of randomly distributed TiO2/air. Using different detection geometries, we measured fluctuations in tαβ and where tαβ is the transmission coefficient coupling the incoming channel α to the outgoing channel β.

•May 21, 1990•25 citations

Quantum interference in light scattering and propagation

Jörg Evers, Mohammad Mahmoudi, Mihai Macovei

Light scattered by a regular structure of atoms exhibits spatial interference signatures, similar to Young's classical double-slit experiment. The first-order interferences, however, are known to vanish for strong light intensities, where the incoherently fluctuating part of the emitted light dominates. Here, we show how to overcome these limitations to quantum interference in stronger laser fields, and how to recover the first-order interference in strong fields by a tailored electromagnetic vacuum with a suitable frequency dependence. We also discuss higher-order correlation functions of the scattered light, with applications, e.g., to lithography. In the second part, we study light propagation of a probe field pulse in closed-loop atomic systems. The closed interaction loop induces a sensitivity to the relative driving field phase, but in general prohibits a stationary steady state. In particular, the finite frequency width of the short probe pulse requires a time-dependent analysis beyond the so-called multiphoton resonance assumption. Using a Floquet decomposition, we identify the different contributions to the medium response, and demonstrate sub- and superluminal light propagation with small absorption or even gain, where a coupling field Rabi frequency allows to switch between sub- and superluminal light propagation.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jun 7, 2007•0 citations

Intensity Fluctuation Techniques in Light Scattering

H. Z. Cummins

Springer eBooks•Jan 1, 1973•0 citations

Intensity-Dependent Resonance Light Scattering

B. R. Mollow

Topics in current physics•Jan 1, 1982•0 citations

Understanding the sensitivity of cavity-enhanced absorption spectroscopy: pathlength enhancement versus noise suppression

Bin Ouyang, Roderic L. Jones

Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 − R ) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 − R ) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 − R )], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present . The enhancement in A = Δ I / I , where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I , but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I ) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this “numerator” term is not improved, the “denominator” term, I , is reduced considerably; therefore, the increase in contrast ratio Δ I / I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I , as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I . No suppression is achievable for noise sources that are independent of I , a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this “noise suppression” argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are “suppressed” by the cavity.

Applied Physics B•Sep 17, 2012•30 citations
Light scattered by a regular structure of atoms exhibits spatial interference signatures, similar to Young's classical double-slit experiment. The first-order interferences, however, are known to vanish for strong light intensities, where the incoherently fluctuating part of the emitted light dominates. Here, we show how to overcome these limitations to quantum interference in stronger laser fields, and how to recover the first-order interference in strong fields by a tailored electromagnetic vacuum with a suitable frequency dependence. We also discuss higher-order correlation functions of the scattered light, with applications, e.g., to lithography. In the second part, we study light propagation of a probe field pulse in closed-loop atomic systems. The closed interaction loop induces a sensitivity to the relative driving field phase, but in general prohibits a stationary steady state. In particular, the finite frequency width of the short probe pulse requires a time-dependent analysis beyond the so-called multiphoton resonance assumption. Using a Floquet decomposition, we identify the different contributions to the medium response, and demonstrate sub- and superluminal light propagation with small absorption or even gain, where a coupling field Rabi frequency allows to switch between sub- and superluminal light propagation.
Cavity-enhanced absorption spectroscopy is now widely used as an ultrasensitive technique in observing weak spectroscopic absorptions. Photons inside the cavity are reflected back and forth between the mirrors with reflectivities R close to one and thus (on average) exploit an absorption pathlength L that is 1/(1 − R ) longer than a single pass measurement. As suggested by the Beer-Lambert law, this increase in L results in enhanced absorbance A (given by αL with α being the absorption coefficient) which in turn favours the detection of weak absorptions. At the same time, however, only (1 − R ) of the incident light can enter the cavity [assuming that mirror transmission T is equal to (1 − R )], so that the reduction in transmitted light intensity Δ I caused by molecular absorption equates to that would be obtained if in fact no cavity were present . The enhancement in A = Δ I / I , where I is the total transmitted light intensity, achievable from CEAS therefore comes not from an increase in Δ I , but a sharp decrease in I. In this paper, we calculate the magnitudes of these two terms before and after a cavity is introduced, and aim at interpreting the sensitivity improvement offered by cavity-enhanced absorption spectroscopy from this observable-oriented (i.e. Δ I and I ) perspective. It is first shown that photon energy stored in the cavity is at best as intense as the input light source, implying that any absorbing sample within the cavity is exposed to the same or even lower light intensity after the cavity is formed. As a consequence, the intensity of the light absorbed or scattered by the sample, which corresponds to the Δ I term aforementioned, is never greater than would be the case in a single pass measurement. It is then shown that while this “numerator” term is not improved, the “denominator” term, I , is reduced considerably; therefore, the increase in contrast ratio Δ I / I is solely contributed by the attenuation of transmitted background light I and is ultimately down to the suppression of any measurement noise that is associated with it. The noise component that is most effectively suppressed is the type whose magnitude scales linearly with light intensity I , as is typical of noise caused by environmental instabilities, followed by the shot noise which scales as square root of I . No suppression is achievable for noise sources that are independent of I , a notable example being the thermal noise of a detector or of detection electronics. The usefulness of this “noise suppression” argument is that it links the sensitivity gain offered by a cavity with the property of measurement noise present in the system, and clearly suggests that the achievable sensitivity is dependent on how efficient the various noise components are “suppressed” by the cavity.