Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

The European Physical Journal A

Steady state signal in the limit of weak optical pumping with D1 or D2 line

S. Łęgowski, P. Rudecki

Published Dec 1, 1983• 2 citations
Publisher
DOI
10.1007/bf01419511

Related papers

Solution of the optical-pumping equation

Sergey V. Bozhokin, Boris G. Matisov

OptSp•Jan 1, 1982•1 citation

Optical pumping effect on modulation transfer spectroscopy of the D1 line of ⁸⁵Rb atoms with non-cycling transition

Jin‐Tae Kim, Shabraz Khan, Heung‐Ryoul Noh

The D_1 line of ^{85}Rb exhibits non-cycling transitions; therefore, only weak modulation transfer spectroscopy (MTS) signals could be obtained \cite{Khan2024}. In this study, however, strong MTS spectra were obtained for the D_1 line via optical pumping (OP) of the D_2 line of $^{85}$Rb. Four linear parallel (lin \parallel lin) and linear perpendicular (lin\perplin), \sigma^+ - \sigma^+, and \sigma^+ - \sigma^- polarization configurations were investigated using an OP laser with four different polarizations such as linear horizontal (P), linear vertical (S), \sigma^+, and \sigma^- polarizations. Under the linear perpendicular configuration, the MTS signal for the F_g=3 \rightarrow F_e=2 transition of the D_1 line exhibited approximately a 41-fold increase in the signal slope in the presence of a linearly-polarized OP beam, compared with the signal slope obtained without OP. The calculated MTS spectra for the \sigma^+ \sigma^- configuration in the presence of \sigma^+- or \sigma^--polarized OP beam as an example matched well with experimental observations.

•Oct 3, 2025•0 citations

Signal Parameters in Optical Pumping Experiments

L. Dellit

De Gruyter eBooks•Dec 31, 1979•0 citations

Optical pumping effect on modulation transfer spectroscopy of the D1 line of ⁸⁵Rb atoms with non-cycling transition

Jin‐Tae Kim, Shabraz Khan, Heung‐Ryoul Noh

The D_1 line of ^{85}Rb exhibits non-cycling transitions; therefore, only weak modulation transfer spectroscopy (MTS) signals could be obtained \cite{Khan2024}. In this study, however, strong MTS spectra were obtained for the D_1 line via optical pumping (OP) of the D_2 line of $^{85}$Rb. Four linear parallel (lin \parallel lin) and linear perpendicular (lin\perplin), \sigma^+ - \sigma^+, and \sigma^+ - \sigma^- polarization configurations were investigated using an OP laser with four different polarizations such as linear horizontal (P), linear vertical (S), \sigma^+, and \sigma^- polarizations. Under the linear perpendicular configuration, the MTS signal for the F_g=3 \rightarrow F_e=2 transition of the D_1 line exhibited approximately a 41-fold increase in the signal slope in the presence of a linearly-polarized OP beam, compared with the signal slope obtained without OP. The calculated MTS spectra for the \sigma^+ \sigma^- configuration in the presence of \sigma^+- or \sigma^--polarized OP beam as an example matched well with experimental observations.

•Oct 3, 2025•0 citations

Fine-structure transfer as a fluorescence readout channel in optically pumped magnetometers

Wanqing Li, Wei Li, Jiaxin Liu

Signal readout in optically pumped magnetometers (OPMs) is usually described in terms of ground-state spin polarization and its Larmor response, while excited-state fine-structure transfer (FST) is absorbed into effective relaxation terms. Here, we treat collision-mediated FST as a fluorescence readout channel under OPM operating conditions. Using steady-state fluorescence spectroscopy, low-frequency magnetic-field modulation, and temperature-dependent Rb-He measurements, we observe collision-generated D2 fluorescence under single-wavelength D1 pumping without direct D2 excitation. The D1 signal is dominated by the modulation frequency ${\mathrm{\ensuremath{\Omega}}}_{m}$, whereas the D2 signal contains a pronounced $2{\mathrm{\ensuremath{\Omega}}}_{m}$ component whose amplitude scales quadratically with the modulation-field amplitude. Unpolarized D2 fluorescence from the ${P}_{3/2}$ level carries a rank-2 alignment term that D1 fluorescence from the ${P}_{1/2}$ level lacks. This selection rule, the $2{\mathrm{\ensuremath{\Omega}}}_{m}$ dominance, and the quadratic scaling together identify the D2 channel as a rank-2-weighted readout opened by FST. From the temperature dependence of the $\mathrm{D}2/\mathrm{D}1$ fluorescence ratio, we obtain an effective Rb-He FST cross section ${\ensuremath{\sigma}}_{\mathrm{eff}}=(2.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}\text{ }{\mathrm{cm}}^{2}$ under an effective symmetric-mixing approximation, consistent with reported Rb-He FST values. The same collision conditions occur in spin-exchange-relaxation-free (SERF) magnetometers, NMR gyroscopes, and spin-exchange optical-pumping cells, where FST affects fluorescence readout and optical-pumping models.

Physical Review Applied•Nov 5, 2026•0 citations

Line profiles in dependence of optical pumping, relaxation and saturation

A. Dönszelmann, Jaap H. M. Neijzen

Optics Communications•Jul 1, 1976•4 citations
The D_1 line of ^{85}Rb exhibits non-cycling transitions; therefore, only weak modulation transfer spectroscopy (MTS) signals could be obtained \cite{Khan2024}. In this study, however, strong MTS spectra were obtained for the D_1 line via optical pumping (OP) of the D_2 line of 85^{85}85Rb. Four linear parallel (lin \parallel lin) and linear perpendicular (lin\perplin), \sigma^+ - \sigma^+, and \sigma^+ - \sigma^- polarization configurations were investigated using an OP laser with four different polarizations such as linear horizontal (P), linear vertical (S), \sigma^+, and \sigma^- polarizations. Under the linear perpendicular configuration, the MTS signal for the F_g=3 \rightarrow F_e=2 transition of the D_1 line exhibited approximately a 41-fold increase in the signal slope in the presence of a linearly-polarized OP beam, compared with the signal slope obtained without OP. The calculated MTS spectra for the \sigma^+ \sigma^- configuration in the presence of \sigma^+- or \sigma^--polarized OP beam as an example matched well with experimental observations.
The D_1 line of ^{85}Rb exhibits non-cycling transitions; therefore, only weak modulation transfer spectroscopy (MTS) signals could be obtained \cite{Khan2024}. In this study, however, strong MTS spectra were obtained for the D_1 line via optical pumping (OP) of the D_2 line of 85^{85}85Rb. Four linear parallel (lin \parallel lin) and linear perpendicular (lin\perplin), \sigma^+ - \sigma^+, and \sigma^+ - \sigma^- polarization configurations were investigated using an OP laser with four different polarizations such as linear horizontal (P), linear vertical (S), \sigma^+, and \sigma^- polarizations. Under the linear perpendicular configuration, the MTS signal for the F_g=3 \rightarrow F_e=2 transition of the D_1 line exhibited approximately a 41-fold increase in the signal slope in the presence of a linearly-polarized OP beam, compared with the signal slope obtained without OP. The calculated MTS spectra for the \sigma^+ \sigma^- configuration in the presence of \sigma^+- or \sigma^--polarized OP beam as an example matched well with experimental observations.
Signal readout in optically pumped magnetometers (OPMs) is usually described in terms of ground-state spin polarization and its Larmor response, while excited-state fine-structure transfer (FST) is absorbed into effective relaxation terms. Here, we treat collision-mediated FST as a fluorescence readout channel under OPM operating conditions. Using steady-state fluorescence spectroscopy, low-frequency magnetic-field modulation, and temperature-dependent Rb-He measurements, we observe collision-generated D2 fluorescence under single-wavelength D1 pumping without direct D2 excitation. The D1 signal is dominated by the modulation frequency ${\mathrm{\ensuremath{\Omega}}}_{m}$, whereas the D2 signal contains a pronounced $2{\mathrm{\ensuremath{\Omega}}}_{m}$ component whose amplitude scales quadratically with the modulation-field amplitude. Unpolarized D2 fluorescence from the P3/2{P}_{3/2}P3/2​ level carries a rank-2 alignment term that D1 fluorescence from the P1/2{P}_{1/2}P1/2​ level lacks. This selection rule, the $2{\mathrm{\ensuremath{\Omega}}}_{m}$ dominance, and the quadratic scaling together identify the D2 channel as a rank-2-weighted readout opened by FST. From the temperature dependence of the D2/D1\mathrm{D}2/\mathrm{D}1D2/D1 fluorescence ratio, we obtain an effective Rb-He FST cross section ${\ensuremath{\sigma}}_{\mathrm{eff}}=(2.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}\text{ }{\mathrm{cm}}^{2}$ under an effective symmetric-mixing approximation, consistent with reported Rb-He FST values. The same collision conditions occur in spin-exchange-relaxation-free (SERF) magnetometers, NMR gyroscopes, and spin-exchange optical-pumping cells, where FST affects fluorescence readout and optical-pumping models.