The D_1 line of ^{85}Rb exhibits non-cycling transitions; therefore, only weak modulation transfer spectroscopy (MTS) signals could be obtained \cite{Khan2024}. In this study, however, strong MTS spectra were obtained for the D_1 line via optical pumping (OP) of the D_2 line of
85Rb. Four linear parallel (lin \parallel lin) and linear perpendicular (lin\perplin), \sigma^+ - \sigma^+, and \sigma^+ - \sigma^- polarization configurations were investigated using an OP laser with four different polarizations such as linear horizontal (P), linear vertical (S), \sigma^+, and \sigma^- polarizations. Under the linear perpendicular configuration, the MTS signal for the F_g=3 \rightarrow F_e=2 transition of the D_1 line exhibited approximately a 41-fold increase in the signal slope in the presence of a linearly-polarized OP beam, compared with the signal slope obtained without OP. The calculated MTS spectra for the \sigma^+ \sigma^- configuration in the presence of \sigma^+- or \sigma^--polarized OP beam as an example matched well with experimental observations.
The D_1 line of ^{85}Rb exhibits non-cycling transitions; therefore, only weak modulation transfer spectroscopy (MTS) signals could be obtained \cite{Khan2024}. In this study, however, strong MTS spectra were obtained for the D_1 line via optical pumping (OP) of the D_2 line of
85Rb. Four linear parallel (lin \parallel lin) and linear perpendicular (lin\perplin), \sigma^+ - \sigma^+, and \sigma^+ - \sigma^- polarization configurations were investigated using an OP laser with four different polarizations such as linear horizontal (P), linear vertical (S), \sigma^+, and \sigma^- polarizations. Under the linear perpendicular configuration, the MTS signal for the F_g=3 \rightarrow F_e=2 transition of the D_1 line exhibited approximately a 41-fold increase in the signal slope in the presence of a linearly-polarized OP beam, compared with the signal slope obtained without OP. The calculated MTS spectra for the \sigma^+ \sigma^- configuration in the presence of \sigma^+- or \sigma^--polarized OP beam as an example matched well with experimental observations.
Signal readout in optically pumped magnetometers (OPMs) is usually described in terms of ground-state spin polarization and its Larmor response, while excited-state fine-structure transfer (FST) is absorbed into effective relaxation terms. Here, we treat collision-mediated FST as a fluorescence readout channel under OPM operating conditions. Using steady-state fluorescence spectroscopy, low-frequency magnetic-field modulation, and temperature-dependent Rb-He measurements, we observe collision-generated D2 fluorescence under single-wavelength D1 pumping without direct D2 excitation. The D1 signal is dominated by the modulation frequency ${\mathrm{\ensuremath{\Omega}}}_{m}$, whereas the D2 signal contains a pronounced $2{\mathrm{\ensuremath{\Omega}}}_{m}$ component whose amplitude scales quadratically with the modulation-field amplitude. Unpolarized D2 fluorescence from the
P3/2 level carries a rank-2 alignment term that D1 fluorescence from the
P1/2 level lacks. This selection rule, the $2{\mathrm{\ensuremath{\Omega}}}_{m}$ dominance, and the quadratic scaling together identify the D2 channel as a rank-2-weighted readout opened by FST. From the temperature dependence of the
D2/D1 fluorescence ratio, we obtain an effective Rb-He FST cross section ${\ensuremath{\sigma}}_{\mathrm{eff}}=(2.7\ifmmode\pm\else\textpm\fi{}0.1)\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}\text{ }{\mathrm{cm}}^{2}$ under an effective symmetric-mixing approximation, consistent with reported Rb-He FST values. The same collision conditions occur in spin-exchange-relaxation-free (SERF) magnetometers, NMR gyroscopes, and spin-exchange optical-pumping cells, where FST affects fluorescence readout and optical-pumping models.