Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of America B

Analysis of amplitude squeezing of harmonic generation in a quasi-phase-matched device: effect of stochastic variation of domain length

Joji Maeda, Ichiro Matsuda, Yutaka Fukuchi

Published Jun 1, 2000• 4 citations
Publisher

Abstract

Amplitude squeezing of the second-harmonic generation in periodically poled quasi-phase-matched devices is analyzed with consideration for errors of the domain length. We show that the amount of squeezing is a complex function of the phase mismatch and of the input power and that it is practically impossible to maintain the perfect quasi-phase matching for an arbitrary input power. For evaluation of the availability of squeezing, we propose a contour map of squeezing that can visualize the tolerance of squeezing for the phase mismatch. It is shown that the effect of domain length error depends on the type of the error; the random duty-cycle error, where the mean domain period is precisely fixed, does not alter the squeezing performance, whereas the random period error, which fluctuates during the domain period, severely alters tuning characteristics. The available amount of squeezing is predicted to be determined by the tuning stability of the device.

DOI
10.1364/josab.17.000942

Related papers

Limit of amplitude squeezing in quasi-phase-matched device for harmonic generation

Joji Maeda, Yutaka Fukuchi, S. Kogoshi

We numerically study amplitude squeezing characteristics of a periodically-poled quasi phase matched (QPM) device designed for harmonic generation, and discuss a relation between precision of the domain length and available amplitude squeezing. We consider a periodically poled device as shown.

Nonlinear Optics•Nov 27, 2002•0 citations

Squeezing in second-harmonic generation using cascaded nonlinear elements

Joji Maeda, Ichiro Matsuda

Cascading of quadratic nonlinearity has been attracting great interests for its potential application to parametric devices, such as phase conjugators or effective Kerr media. In most configurations, the device consists of a single nonlinear element with uniform phase-mismatch. Cascading of several elements with different phase-mismatch has been theoretically investigated and predicted to improve performance of the device for classical applications. In this paper, amplitude squeezing in second-harmonic generation using cascaded quadratic nonlinear elements is numerically analyzed. The analyses are based on linearization of nonlinear coupling equations, where interacting fields are approximated as plane waves. Phase-mismatch of each element is varied independently and tolerance of squeezing performance to the fluctuation of the phase-mismatch is also investigated. It is predicted that the performance as a squeezing device can be also superior to that of a single element device, if a proper combination of the phase-mismatch of each element is chosen. For the fundamental wave, the tolerance to the fluctuation of the phase-mismatch will improve by nearly tenfold compared with the single element case. For the harmonic wave, squeezing beyond the limit of perfect phase-matched case (3dB) will be available, though the tolerance to the fluctuation of the phase-mismatch is quite small. These improvements can be attributed to the nonlinear phase rotation that keeps squeezed axis coincided with the amplitude phase in a stable manner.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•May 16, 2003•0 citations

Influence of the randomly varying domain length of quasi-phase-matched crystals on quadrature squeezing performance

Yongmin Li, Wu Ying-Rui, Kuanshou Zhang +2 more

During the fabrication of quasi-phase-matched (QPM) devices, errors of periodic structure are usually inevitable. The errors result in the deviation of the actual periodic domain length from the theoretical value. In this paper, we numerically analyse the influence of errors on the quadrature squeezing performance of a degenerate optical parametric amplifier consisting of QPM devices. It is shown that errors significantly degrade the squeezing degree of the quadrature squeezed light. Due to the presence of the errors, the relative phase between the signal and the pump field for obtaining the maximum squeezing depends on the propagation distance of light in the crystal and the pump power.

Chinese Physics•Jul 31, 2002•2 citations

Influence of the randomly varying domain length of quasi-phase-matched crystals on quadrature squeezing performance

李永民, 吴迎瑞, 张宽收 +2 more

During the fabrication of quasi-phase-matched(QPM) devices,errors of periodic structure are usually inevitable.The errors result in the deviation of the actual periodic domain length from the theoretical value.In this paper,we numerically analyse the influence of errors on the quadrature squeezing performance of a degenerate optical parametric amplifier consisting of QPM devices.It is shown that errors significantly degrade the squeezing degree of the quadrature squeezed light.Due to the presence of the errors,the relative phase between the signal and the pump field for obtaining the maximum squezing depends on the propagation distance of light in the crystal and the pump power.

中国物理B:英文版•Jun 12, 2005•0 citations

Squeezing in downconversion in a quasi-phase-matched medium

Vijay S. Chickarmane, G. S. Agarwal

We consider the generation of squeezed light in the process of degenerate downconversion in a quasi-phase-matched periodically poled nonlinear medium. The squeezing in the downconverted mode is analyzed for different orders of quasi-phase matching and for phase-mismatch parameter as well as varying pump input powers. The results show that a high degree of squeezing and high powers can be obtained for well-matched interactions.

Optics Letters•Jul 15, 1998•5 citations

Squeezing characteristics analysis of a fundamental-confined second-harmonic generation system by means of a self-consistent method

Joji Maeda, Kazuro Kikuchi

We discuss quantum-fluctuation characteristics of a second-harmonic generation system that uses an optical resonator to confine only the fundamental field. It was predicted that the available amount of squeezing is limited to 1.76 dB for the fundamental output and 9.54 dB for the second-harmonic output, respectively, irrespective of system parameters. However, these predictions are based on low-order perturbation theory and are unavailable if the nonlinear coupling between the fundamental and the second harmonic becomes large. We consider the spatial evolution of the fields and reveal that the maximum amount of squeezing depends on the cavity loss: Even an arbitrary amount of squeezing is possible for both the fundamental output and the second-harmonic output. We also consider the possibility of parametric oscillation of empty cavity modes pumped by the generated second harmonic and derive the following prediction: In a system that uses a type I phase-matched crystal, the oscillation of the side mode hardly occurs because of sum-frequency generation with the fundamental and scarcely imposes any limitations on squeezing. On the other hand, a system with a type II phase-matched crystal suffers from the oscillation of the polarization mode orthogonal to that of the fundamental input, and squeezing of the second-harmonic output is limited to 3 dB.

Journal of the Optical Society of America B•Mar 1, 1997•9 citations
Amplitude squeezing of the second-harmonic generation in periodically poled quasi-phase-matched devices is analyzed with consideration for errors of the domain length. We show that the amount of squeezing is a complex function of the phase mismatch and of the input power and that it is practically impossible to maintain the perfect quasi-phase matching for an arbitrary input power. For evaluation of the availability of squeezing, we propose a contour map of squeezing that can visualize the tolerance of squeezing for the phase mismatch. It is shown that the effect of domain length error depends on the type of the error; the random duty-cycle error, where the mean domain period is precisely fixed, does not alter the squeezing performance, whereas the random period error, which fluctuates during the domain period, severely alters tuning characteristics. The available amount of squeezing is predicted to be determined by the tuning stability of the device.
Cascading of quadratic nonlinearity has been attracting great interests for its potential application to parametric devices, such as phase conjugators or effective Kerr media. In most configurations, the device consists of a single nonlinear element with uniform phase-mismatch. Cascading of several elements with different phase-mismatch has been theoretically investigated and predicted to improve performance of the device for classical applications. In this paper, amplitude squeezing in second-harmonic generation using cascaded quadratic nonlinear elements is numerically analyzed. The analyses are based on linearization of nonlinear coupling equations, where interacting fields are approximated as plane waves. Phase-mismatch of each element is varied independently and tolerance of squeezing performance to the fluctuation of the phase-mismatch is also investigated. It is predicted that the performance as a squeezing device can be also superior to that of a single element device, if a proper combination of the phase-mismatch of each element is chosen. For the fundamental wave, the tolerance to the fluctuation of the phase-mismatch will improve by nearly tenfold compared with the single element case. For the harmonic wave, squeezing beyond the limit of perfect phase-matched case (3dB) will be available, though the tolerance to the fluctuation of the phase-mismatch is quite small. These improvements can be attributed to the nonlinear phase rotation that keeps squeezed axis coincided with the amplitude phase in a stable manner.
During the fabrication of quasi-phase-matched (QPM) devices, errors of periodic structure are usually inevitable. The errors result in the deviation of the actual periodic domain length from the theoretical value. In this paper, we numerically analyse the influence of errors on the quadrature squeezing performance of a degenerate optical parametric amplifier consisting of QPM devices. It is shown that errors significantly degrade the squeezing degree of the quadrature squeezed light. Due to the presence of the errors, the relative phase between the signal and the pump field for obtaining the maximum squeezing depends on the propagation distance of light in the crystal and the pump power.
During the fabrication of quasi-phase-matched(QPM) devices,errors of periodic structure are usually inevitable.The errors result in the deviation of the actual periodic domain length from the theoretical value.In this paper,we numerically analyse the influence of errors on the quadrature squeezing performance of a degenerate optical parametric amplifier consisting of QPM devices.It is shown that errors significantly degrade the squeezing degree of the quadrature squeezed light.Due to the presence of the errors,the relative phase between the signal and the pump field for obtaining the maximum squezing depends on the propagation distance of light in the crystal and the pump power.
We discuss quantum-fluctuation characteristics of a second-harmonic generation system that uses an optical resonator to confine only the fundamental field. It was predicted that the available amount of squeezing is limited to 1.76 dB for the fundamental output and 9.54 dB for the second-harmonic output, respectively, irrespective of system parameters. However, these predictions are based on low-order perturbation theory and are unavailable if the nonlinear coupling between the fundamental and the second harmonic becomes large. We consider the spatial evolution of the fields and reveal that the maximum amount of squeezing depends on the cavity loss: Even an arbitrary amount of squeezing is possible for both the fundamental output and the second-harmonic output. We also consider the possibility of parametric oscillation of empty cavity modes pumped by the generated second harmonic and derive the following prediction: In a system that uses a type I phase-matched crystal, the oscillation of the side mode hardly occurs because of sum-frequency generation with the fundamental and scarcely imposes any limitations on squeezing. On the other hand, a system with a type II phase-matched crystal suffers from the oscillation of the polarization mode orthogonal to that of the fundamental input, and squeezing of the second-harmonic output is limited to 3 dB.