Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Foundations of Quantum Mechanics in the Light of New Technology

A DC STARK FREE ATOM INTERFEROMETER HAVING TWO ARMS WITH DIFFERENT ZEEMAN SUBLEVELS FOR MEASUREMENT OF THE AHARONOV-CASHER EFFECT

Shinya Yanagimachi, M. Kajiro, Atsuo Morinaga

Published Oct 1, 2002• 0 citations
Publisher
DOI
10.1142/9789812776716_0030

Related papers

EXPERIMENTAL VERIFICATION OF THE AHARONOV-CASHER EFFECT FOR NEUTRONS WITH A CRYSTAL INTERFEROMETER

G. I. Opat, Alberto Cimmino, A. G. KLEIN +4 more

•Mar 1, 1991•0 citations

Measurement of the Aharonov-Casher geometric phase with a separated-arm atom interferometer

Jonathan Gillot, S. Lepoutre, A. Gauguet +2 more

arXiv:1312.3453•The European Physical Journal D•Jun 1, 2014•13 citations

Interference between the Aharonov-Bohm and Aharonov-Casher effects

Xiao-Gang He

•Jan 1, 1991•0 citations

Paradoxes of the Aharonov-Bohm and the Aharonov-Casher Effects

Lev Vaidman A

arXiv:1301.6153•Springer eBooks•Sep 12, 2013•2 citations

Atom interferometry in a static electric field: Measurement of the Aharonov-Casher phase

K. Zeiske, G. Zinner, F. Riehle +1 more

Applied Physics B•Jan 1, 1995•54 citations

Atomic multiwave interferometer for Aharonov-Casher-phase measurements

Min-Kang Zhou, Ke Zhang, Xiao‐Chun Duan +3 more

We present an atomic multiwave interferometer with magnetic sublevels to precisely determine the Aharonov-Casher (AC) geometric phase. Simulations show that this interferometer has sharper fringes than a normal two-wave interferometer, which means a higher phase resolution can be achieved. Moreover, atoms evolving in a single hyperfine structure state make the interferometer insensitive to the dc Stark phase shift. This dc Stark shift is one of the main noise sources in AC phase measurements. The constraint of the photon rest mass is also discussed when using this atomic interferometer to measure the Aharonov-Casher phase.

Physical Review A•Feb 24, 2016•6 citations
We present an atomic multiwave interferometer with magnetic sublevels to precisely determine the Aharonov-Casher (AC) geometric phase. Simulations show that this interferometer has sharper fringes than a normal two-wave interferometer, which means a higher phase resolution can be achieved. Moreover, atoms evolving in a single hyperfine structure state make the interferometer insensitive to the dc Stark phase shift. This dc Stark shift is one of the main noise sources in AC phase measurements. The constraint of the photon rest mass is also discussed when using this atomic interferometer to measure the Aharonov-Casher phase.