Physical Review A

Calibration of single-photon detectors using quantum statistics

Dmitri S. Mogilevtsev

Published Aug 31, 2010• 26 citations
Publisher

Abstract

I show that calibration of the single-photon detector can be performed without knowledge of the signal parameters. Only partial information about the state statistics is sufficient for that. If one knows that the state is the squeezed one or the squeezed one mixed with the incoherent radiation, one can infer both the parameters of the state and the efficiency of the detector. For that one needs only to measure on/off statistics of detector clicks for the number of known absorbers placed before the detector. Thus, I suggest a scheme that performs a tomography of the signal and the measuring apparatus simultaneously.

DOI
10.1103/physreva.82.021807

Related papers

Absolute calibration of single-photon and multiplexed photon-number-resolving detectors

Lior Cohen, Y. Pilnyak, D. Istrati +3 more

Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.

arXiv:1711.03594•Physical Review A•Jul 5, 2018•27 citations

Self-calibration for self-consistent tomography

Dmitri S. Mogilevtsev, Jaroslav Řeháček, Z. Hradil

Self-calibrating states are introduced as quantum resources for the simultaneous reconstruction of a quantum state and measurement device. Simple criteria for a state being self-calibrating are formulated. Theory applies to realistic state estimation scenarios, where the detection model is nonlinear in unknown parameters of the measuring device. Examples discussed include time multiplexed detection with on/off detectors and quantum homodyne tomography. The thermally noised single-photon states and Gaussian states are self-calibrating for these schemes. For homodyne tomography, statistical tests applied to raw measured data are sufficient for judging whether or not the signal state is self-calibrating without any a priori information.

New Journal of Physics•Sep 3, 2012•37 citations

Proposal for calibration of a single-photon counting detector without the need of input photon flux calibration

Thomas Gerrits

A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.

Optics Express•Apr 4, 2016•0 citations

Proposal for calibration of a single-photon counting detector without the need of input photon flux calibration

Thomas Gerrits

Abstract A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.

Journal of Optics•Apr 4, 2016•4 citations

A proposed testbed for detector tomography

Hendrik B. Coldenstrodt-Ronge, Jeff S. Lundeen, Kenny L. Pregnell +7 more

Measurement is the only part of a general quantum system that has yet to be characterised experimentally in a complete manner. Detector tomography provides a procedure for doing just this; an arbitrary measurement device can be fully characterised, and thus calibrated, in a systematic way without access to its components or its design. The result is a reconstructed POVM containing the measurement operators associated with each measurement outcome. We consider two detectors, a single-photon detector and a photon-number counter, and propose an easily realised experimental apparatus to perform detector tomography on them. We also present a method of visualising the resulting measurement operators.

arXiv:0902.4384•Journal of Modern Optics•Oct 31, 2008•42 citations

Calibration of a single-photon counting detectors without the need of input photon flux calibration (Conference Presentation)

Thomas Gerrits

Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102–9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478–481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390–1407 (2007). [5] A. Avella et al., Optics Express 19, 23249–23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)

•Jun 9, 2017•0 citations
I show that calibration of the single-photon detector can be performed without knowledge of the signal parameters. Only partial information about the state statistics is sufficient for that. If one knows that the state is the squeezed one or the squeezed one mixed with the incoherent radiation, one can infer both the parameters of the state and the efficiency of the detector. For that one needs only to measure on/off statistics of detector clicks for the number of known absorbers placed before the detector. Thus, I suggest a scheme that performs a tomography of the signal and the measuring apparatus simultaneously.
Single-photon detectors are widely used in modern quantum optics experiments and applications. Like all detectors, it is important for these devices to be accurately calibrated. A single-photon detector is calibrated by determining its detection efficiency; the common method to measure this quantity requires comparison to another detector. Here, we suggest a method to measure the detection efficiency of a single-photon detector without requiring an external reference detector. Our method is valid for individual single-photon detectors as well as multiplexed detectors, which are known to be photon number resolving. The method exploits the even-number photon-statistics of a nonlinear source, as well as the nonlinear loss of a single-photon detector that occurs when multiple photons are incident simultaneously. We have analytically modeled multiplexed detectors and used the results to experimentally demonstrate the calibration of a single-photon detector without the need for an external reference detector.
Self-calibrating states are introduced as quantum resources for the simultaneous reconstruction of a quantum state and measurement device. Simple criteria for a state being self-calibrating are formulated. Theory applies to realistic state estimation scenarios, where the detection model is nonlinear in unknown parameters of the measuring device. Examples discussed include time multiplexed detection with on/off detectors and quantum homodyne tomography. The thermally noised single-photon states and Gaussian states are self-calibrating for these schemes. For homodyne tomography, statistical tests applied to raw measured data are sufficient for judging whether or not the signal state is self-calibrating without any a priori information.
A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.
Abstract A method for calibration of single-photon detectors without the need of input photon flux calibration is presented. The method relies on the use of waveguide-coupled single photon detectors and a series of photon-counting measurements using a single-photon source. It is shown that the method can yield relative uncertainties of less than 1% including counting statistics and fiber splice loss uncertainties with a total measurement time of about 1 h under the assumptions that the fractional losses of the waveguide-coupled detectors are known or zero and the loss along the waveguide is constant. It is also shown that the fractional losses of the waveguide-coupled detectors can be determined if they are equal. However, in this case an input photon flux calibration is required.
Measurement is the only part of a general quantum system that has yet to be characterised experimentally in a complete manner. Detector tomography provides a procedure for doing just this; an arbitrary measurement device can be fully characterised, and thus calibrated, in a systematic way without access to its components or its design. The result is a reconstructed POVM containing the measurement operators associated with each measurement outcome. We consider two detectors, a single-photon detector and a photon-number counter, and propose an easily realised experimental apparatus to perform detector tomography on them. We also present a method of visualising the resulting measurement operators.
Calibration of fiber-coupled single-photon detectors usually requires knowledge of the input photon flux inside the fiber and/or knowledge of the linearity of a reference power meter. Many approaches have been presented in the past to accurately measure the photon detection probability of a single photon detector [1-6]. Under certain assumptions, one can utilize waveguide-coupled single photon detectors and a series of photon-counting measurements and a single-photon source to calibrate the detection efficiency of a single photon detector without the need of a reference power meter and the knowledge of the incoming photon flux. Here, this method is presented. Furthermore, if a reference detector is used, the detection efficiency of all evanescently coupled waveguide detectors can be measured, and the measurement outcome does not depend on splicing or fiber connection losses within in the setup, i.e., the measurement is setup-independent. In addition, the method, when using a reference detector, can be utilized to measure and distinguish between the absorption of a waveguide-coupled single photon detector and its internal detection efficiency. [1] A. J. Miller et al, Opt. Express 19, 9102–9110 (2011) [2] I. Muller et al., Metrologia 51, S329 (2014). [3] A. L. Migdall, Instrumentation and Measurement, IEEE Transactions on 50, 478–481 (2001). [4] S. V. Polyakov, A. L. Migdall, Optics Express 15, 1390–1407 (2007). [5] A. Avella et al., Optics Express 19, 23249–23257 (2011). [6] T. Lunghi et al., Opt. Express 22, 18078-18092 (2014)