The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.
The sensitivity of a kinetic inductance detector is determined by the performance of the cavity circuit and therefore a high quality factor and low phase noise are required. We developed superconducting niobium coplanar waveguide resonators for kinetic inductance detectors at a resonance frequency of 6 GHz. The length of the resonators is adjusted to a quarter of a wavelength which corresponds to ≈ 5.3 mm in our geometry. Different layouts with coplanar waveguide transmission line topology for the resonator were designed and simulated. Some parameters of the device fabrication process were varied. The niobium thin films were deposited by magnetron sputtering on sapphire substrates kept at ambient temperature. The resonators were patterned by photolithography and reactive ion etching and measured at helium temperatures. Because of the quarter wave geometry with one shorted end the reflection parameter was measured. We have studied the influence of the coupling capacitances on quality factor. The optimization includes microwave simulations and implementation in different resonator structures. The measurements of optimized devices showed a very high quality factor above one million (10 6 ). The obtained results and perspective on further development of resonators will be discussed.
The use of a transmission line resonator offers the possibility for different sensor readout methods, e.g. flux qubit and kinetic inductance detectors. Both cases require a high quality factor, Q L , of the cavity circuit to detect small deviations in the resonance frequency. Various superconducting niobium coplanar waveguide resonators of λ/4 and λ/2 wavelength for 3 and 6 GHz were developed. Different layouts for the coplanar resonators were designed, simulated and measured on common silicon and sapphire substrates at 4.2 K. We found a very good agreement between simulation and measurement results, with Q L between 10 4 and 10 5 at helium temperatures. The presented results show the dependences on the chosen cross section geometries, the coupling factor and the complex layout of the transmission line.
We report our development on design, fabrication and characterization of various superconducting resonators for quantum device applications. The resonators are developed mainly for superconducting qubit implementation in circuit QED structure, but future application will include photon detectors such as microwave kinetic inductance detectors. First we designed and fabricated half-wavelength coplanar waveguide resonators with niobium thin film on a high resistive silicon wafer, with the fundamental frequencies in the range of 1 to 8 GHz. The loaded quality factors are controlled by the coupling capacitors, and the lower bound of the intrinsic quality factor was measured down to 7 mK in the dilution refrigerator. We have also designed quarter-wavelength resonators and lumped LC resonators coupled to a transmission line, and characterized multiple resonators in a single transmission line. For the 3D transmon qubit application, we designed and fabricated a rectangular box resonator with superconducting aluminum. The intrinsic quality factor of the box resonator exceeds three million at 7 mK. We will also present basic results on the integration of a transmon qubit in the superconducting resonator.
We successfully designed and fabricated an absorption-type of superconducting coplanar waveguide (CPW) resonators. The resonators are made from a niobium film (about 160 nm thick) on a high-resistance Si substrate, and each resonator is fabricated as a meandered quarter-wavelength transmission line (one end is short to the ground and another end is capacitively coupled to a through feedline). With a vector network analyzer we measured the transmissions of the applied microwave through the resonators at ultra-low temperature. The obtained loaded quality factors are significantly high, i.e. up to ∼10 6 . When the temperature increases slowly from the base temperature (20 mK), the resonance frequencies of the resonators are blue shifted and the quality factors are lowered slightly. In principle, this type of device can integrate a series of CPW resonators with a common feedline, making it a promising candidate as the data bus for coupling distant solid-state qubits and the sensitive detector of single photons.
Abstract : Over the last decade, quantum information experiments with trapped ions have demonstrated essential steps towards quantum computing and quantum simulation. Large fields are required to achieve strong coupling to the ions via dipolar interactions, and so we fabricated transmission line microresonators - capable of producing large fields in a standing wave at resonance - for eventual integration into 2D ion trap structures. The resonators were superconducting to minimize loss and maximize quality factor. We fabricated the resonators as two dimensional coplanar waveguides in niobium on R-plane sapphire using optical lithography. Resist was patterned on the niobium using optical lithography, developed then reactive-ion etched to transfer the pattern into the niobium. The resonators were cooled and tested in a cryogenic probe station and characterized with a network analyzer. Additionally, the resonator geometry was reproduced in commercial microwave simulation software. Results from our fabricated resonators showed first-resonance quality factors of 1.2 x 104 at 3.23 GHz at device temperatures of 3-4 K.
In this master's thesis, I present the design, fabrication, and characterisation of superconducting microwave resonators. These resonators are quarter-wavelength coplanar waveguide resonators, operating at resonance frequencies between 4 GHz and 8 GHz. This kind of resonator is a key component in several applications, ranging from quantum computation devices to parametric amplifiers. Minimising the losses (achieving high internal quality factors) in these resonators is important to maximise performance of the applications they are used for. During the thesis work, we have studied several possible changes to improve the resonator quality.\n\nFabrication of the resonators was done in the Nanofabrication Laboratory at Chalmers University of Technology, and consist of the following steps: cleaning a sapphire or silicon wafer, depositing a layer of superconducting niobium, photolithography, and etching the waveguide. We then measured the resonators in a cryogen-free dilution refrigerator, at a temperature of 10 mK. The measurements consisted of a power sweep, in order to quantify the quality factor at high and low excitation powers. As an example, the first resonator we fabricated had a quality factor of 4.3 x 10^4 at high power (about 10^5 photons in the resonator), and quality factor of 3.7 x 10^4 at the single-photon level.\n\nWe then investigated different loss mechanisms that we expect to negatively affect the quality factor, and how to reduce this loss. Firstly, to reduce radiation losses and magnetic vortex losses, we reduced the lateral dimensions of the resonator. Secondly, as two-level system (TLS) losses are believed to mainly reside at the surfaces of the materials and interfaces between them, we etched into the substrate to selectively move a part of the TLS away from the resonator. We also studied the effect of the meandering of the resonator on the quality factor, as well as using two different etching gasses.\n\nBy gathering all this data, we were then able to compare the different combinations to see the effect of the changing parameters. In conclusion, the reduced lateral dimensions and the removal of part of the substrate indeed reduce the losses, as expected from the theory. We also found interesting behaviour with regards to the meandering, namely that having a meandered structure negatively affects the quality factor.\n\nCombining all results, we can give a guideline for the fabrication of resonators in the future, which gave us a quality factor up to 4.9 x 10^5 at high excitation power, and 3.0 x 10^5 at the single photon level.
This article is focused on the design and development of superconducting Microwave Kinetic Inductance Detector (MKID) which is used at near, mid and far-infrared, optical and ultraviolet wavelengths for astronomical applications. MKIDs are superconducting micro-resonators which are very much considered, due to high sensitivity, simplicity in fabrication and ease of read out by a coplanar waveguide or microstrip transmission line. Here a new structure for inductor of lumped element microwave resonator is proposed that causes a very high Quality factor in smaller dimensions. Our resonator's intrinsic Q factor is above 8×106in dimensions of 441×487 μm2which is the highest value in such dimensions. due to the small dimensions of this resonator, makes it desirable to use in large arrays spectrometers.