Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

Fluorescence ghost imaging

Giuliano Scarcelli, Seok Hyun Yun

Published Aug 20, 2009• 0 citations
Publisher

Abstract

We introduce a method of using the second-order correlation of entangled photon pairs for fluorescence imaging. The method relies on the fact that one photon of the pair carries information on where the other photon has been absorbed and has produced fluorescence in a sample. Because fluorescent molecules serve as "detectors" breaking the entanglement, multiply-scattered fluorescence photons within the sample do not cause image blur. We discuss practical implementations.

DOI
10.1117/12.824390

Related papers

Entangled-photon coincidence fluorescence imaging

Giuliano Scarcelli, Seok Hyun Yun

We describe fluorescence imaging using the second-order correlation of entangled photon pairs. The proposed method is based on the principle that one photon of the pair carries information on where the other photon has been absorbed and has produced fluorescence in a sample. Because fluorescent molecules serve as "detectors" breaking the entanglement, multiply-scattered fluorescence photons within the sample do not cause image blur. We discuss experimental implementations.

arXiv:0812.1516•Optics Express•Sep 26, 2008•18 citations

Applications of Quantum Entanglement Towards “Ghost” Imaging

Weronika Pach

In this work, pairs of entangled photons are aimed at two spatially separated detectors: the path to one detector contains a physical object, while the path to the second detector does not. Yet, the second detector can be used to create an image of the object, even though none of the photons arriving at that detector have ever interacted with the object! This “ghost” imaging takes advantage of information that is shared between entangled photon pairs. This work aims to explore the underlying principles in a ghost imaging system that utilizes spontaneous parametric down-conversion (SPDC) as the source of entangled photons, with the larger goal of understanding the principles and operation of key parts of the system.

•Jan 1, 2018•0 citations

3D quantum ghost imaging microscope

Audrey V. Eshun, Dominique Davenport, Brandon J. Demory +11 more

Quantum ghost imaging uses quantum-entangled photons to generate a two-dimensional image with only a bucket detector at the sample. Here we expand on this approach to generate a three-dimensional image without scanning. A quantum-entangled light source directly links information between a pair of 2D sensors, one of which captures a standard image from one perspective and a second sensor which captures a ghost image from a perpendicular perspective. By correlating the spatial information from the two detectors for each photon pair, we obtain three dimensions of spatial information ( x , y , and z ) for each scattered photon. We demonstrate that this system can study microscopic environments by imaging scattering from metallic nanoparticle clusters. This approach has the potential to greatly reduce the flux of light required to obtain a 3D image of a biological sample and thereby extend the number of images that can be obtained before photodamaging the sample.

Optica•Jun 25, 2025•7 citations

Scanning Single Photon Detector Implementation of Quantum “Ghost Imaging”

Tao Jin, Minzhao Liu

Entangled photons can be exploited for single-photon imaging: photons are accumulated one by one to form an image on a camera. To improve the signal-to-noise ratio, one can use “heralded imaging,” where camera data is only accepted if a partner (entangled) photon is detected in coincidence, at a second detector. A secondary consequence of the strong correlations between entangled photons is that we can place the object into the path of the second detector, and yet still create an image on the original camera, using only photons that never interacted with the viewed object. This configuration is called “ghost imaging.” To reduce cost, we designed and implemented a modified version, replacing the fast-gated camera with single-photon sensitivity with a single-pixel detector that scans the image plane. Our design had to carefully preserve optical alignment so that the detector is always pointing at the source of entangled photons. Our next step will be to use ghost diffraction to demonstrate that entangled phone pairs are correlated in ways that extend beyond what is allowed by classical physics.

•Jan 1, 2019•0 citations

Heralded single-photon ghost imaging

Reuben S. Aspden, D. S. Tasca, Robert W. Boyd +1 more

Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.

•Dec 20, 2012•1 citation

Quantum Imaging Using Entangled Photon Pairs From Nonlinear Metasurfaces

Jinliang Ren, Jinyong Ma, Jihua Zhang +1 more

We present a novel imaging technique that combines quantum ghost and scanning imaging protocol to capture two-dimensional images using only a one-dimensional detector array, enabled by strong spatial correlations and tunable emission angle of entangled photon pairs emitted from an ultrathin nonlinear metasurface.

International Congress on Artificial Materials for Novel Wave Phenomena (Metamaterials)•Sep 11, 2023•0 citations
We introduce a method of using the second-order correlation of entangled photon pairs for fluorescence imaging. The method relies on the fact that one photon of the pair carries information on where the other photon has been absorbed and has produced fluorescence in a sample. Because fluorescent molecules serve as "detectors" breaking the entanglement, multiply-scattered fluorescence photons within the sample do not cause image blur. We discuss practical implementations.
In this work, pairs of entangled photons are aimed at two spatially separated detectors: the path to one detector contains a physical object, while the path to the second detector does not. Yet, the second detector can be used to create an image of the object, even though none of the photons arriving at that detector have ever interacted with the object! This “ghost” imaging takes advantage of information that is shared between entangled photon pairs. This work aims to explore the underlying principles in a ghost imaging system that utilizes spontaneous parametric down-conversion (SPDC) as the source of entangled photons, with the larger goal of understanding the principles and operation of key parts of the system.
Quantum ghost imaging uses quantum-entangled photons to generate a two-dimensional image with only a bucket detector at the sample. Here we expand on this approach to generate a three-dimensional image without scanning. A quantum-entangled light source directly links information between a pair of 2D sensors, one of which captures a standard image from one perspective and a second sensor which captures a ghost image from a perpendicular perspective. By correlating the spatial information from the two detectors for each photon pair, we obtain three dimensions of spatial information ( x , y , and z ) for each scattered photon. We demonstrate that this system can study microscopic environments by imaging scattering from metallic nanoparticle clusters. This approach has the potential to greatly reduce the flux of light required to obtain a 3D image of a biological sample and thereby extend the number of images that can be obtained before photodamaging the sample.
Entangled photons can be exploited for single-photon imaging: photons are accumulated one by one to form an image on a camera. To improve the signal-to-noise ratio, one can use “heralded imaging,” where camera data is only accepted if a partner (entangled) photon is detected in coincidence, at a second detector. A secondary consequence of the strong correlations between entangled photons is that we can place the object into the path of the second detector, and yet still create an image on the original camera, using only photons that never interacted with the viewed object. This configuration is called “ghost imaging.” To reduce cost, we designed and implemented a modified version, replacing the fast-gated camera with single-photon sensitivity with a single-pixel detector that scans the image plane. Our design had to carefully preserve optical alignment so that the detector is always pointing at the source of entangled photons. Our next step will be to use ghost diffraction to demonstrate that entangled phone pairs are correlated in ways that extend beyond what is allowed by classical physics.
Correlated-photon imaging, popularly known as ghost imaging, is a technique whereby an image is formed from light that has never interacted with the object. In ghost imaging experiments two correlated light fields are produced. One of these fields illuminates the object, and the other field is measured by a spatially resolving detector. In the quantum regime, these correlated light fields are produced by entangled photons created by spontaneous parametric down-conversion. To date, all correlated-photon ghost-imaging experiments have scanned a single-pixel detector through the field of view to obtain the spatial information. However, scanning leads to a poor sampling efficiency, which scales inversely with the number of pixels, N, in the image. In this work we overcome this limitation by using a time-gated camera to record the single-photon events across the full scene. We obtain high-contrast images, 90%, in either the image plane or the far-field of the photon pair source, taking advantage of the EPR-like correlations in position and momentum of the photon pairs. Our images contain a large number of modes, >500, creating opportunities in low-light-level imaging and in quantum information processing.