Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics

High-resolution fluorescence microscopy employing a cyclic sequential multiphoton excitation

Keisuke Isobe, Akira Suda, Hiroshi Hashimoto, Fumihiko Kannari, Hiroyuki Kawano, Hideaki Mizuno, Atsushi Miyawaki, Katsumi Midorikawa

Published Jan 1, 2010• 1 citation
Publisher

Abstract

We demonstrate high-resolution fluorescence microscopy based on a cyclic sequential multiphoton process, which gives rise to fluorescence emission following a sequence of cyclic transitions between the bright and dark states of a fluorophore.
DOI
10.1364/cleo.2010.cthcc4

Related papers

Subwavelength resolution via dark state

Yuri V. Rostovtsev, Marian O. Scully

We study improving of spatial resolution of fluorescence microscopy by using dark states formed via interaction with bi-chromatic optical fields. This approach has applications to coherent Raman spectroscopy.

Frontiers in Optics•Jan 1, 2007•0 citations

Fluorophore discrimination by tracing quantum interference in fluorescence microscopy

Arijit K. De, Debjit Roy, Debabrata Goswami

We show fluorescence-detected quantum interference in a microscope setup and demonstrate selective enhancement or suppression of fluorophores using femtosecond pulse-pair excitation with periodic modulation of the interpulse phase.

Physical Review A•Jan 21, 2011•9 citations

Super-resolving nonlinear fluorescence microscopy with pump–probe setup using repetitive stimulated transition

Fumihiro Dake, Naoki Fukutake, Seri Hayashi +1 more

Super-resolving nonlinear fluorescence microscopy with a pump–probe setup that utilizes repetitive stimulated absorption and stimulated emission caused by two-color beams was developed. The resulting nonlinear fluorescence that undergoes such a repetitive stimulated transition is detectable as a signal via the lock-in technique. The signal is produced by a multiplicative combination of incident beams, which leads to an improvement of the optical resolution. A phenomenological interpretation of the nonlinear fluorescence process that offers estimation of signal properties is provided with rate equations. The proposed method is demonstrated to provide the scalability of the optical resolution.

Applied Physics Express•Dec 27, 2017•4 citations

Nanoscale resolution fluorescence microscopy using electromagnetically induced transparency

Deniz D. Yavuz, Nicholas Proite

We suggest a type of scanning fluorescence microscope that is capable of resolving nanometer-size objects in the far field. The key idea is to use the spatial sensitivity of the dark state of electromagnetically induced transparency and localize an atomic excitation to a spot much smaller than the wavelength of light.

Physical Review A•Oct 18, 2007•76 citations

Improved resolution in fluorescence microscopy using quantum correlations

Osip Schwartz, Dan Oron

Breaking the diffraction limit in microscopy by utilizing the quantum properties of light has been the goal of intense research in recent years. We propose a super-resolution technique based on nonclassical emission statistics of fluorescent markers, routinely used as contrast labels for bioimaging. The technique can be readily implemented with current technology.

arXiv:1101.5013•Physical Review A•Mar 16, 2012•91 citations

Universal scaling of resolution with photon number in superresolution fluorescence microscopy

Alexander R. Small

Superresolution fluorescence microscopy techniques beat the diffraction limit, enabling ultra-high resolution imaging in biological physics and nanoscience. In all cases that have been studied experimentally, the resolution scales inversely with the square root of some parameter that measures the number of photons used. However, this ubiquitous limit arises from very distinct mechanisms in different approaches, raising the question of whether it is a fundamental limit that cannot be exceeded, or merely a coincidence of the techniques studied thus far. We demonstrate that, under very general assumptions that encompass essentially all fluorescence microscopy situations, the known resolution limit is indeed universal. Our model considers experiments that build up an image via any arbitrary sequence of steps compatible with our assumptions of (1) light that exhibits shot noise and (2) molecules that can be modeled with rate equations. A detailed examination of our assumptions shows that exceeding this resolution limit will require the use of quantum optical effects, pointing to an avenue for future innovation.

arXiv:1209.4411•Sep 20, 2012•0 citations
Super-resolving nonlinear fluorescence microscopy with a pump–probe setup that utilizes repetitive stimulated absorption and stimulated emission caused by two-color beams was developed. The resulting nonlinear fluorescence that undergoes such a repetitive stimulated transition is detectable as a signal via the lock-in technique. The signal is produced by a multiplicative combination of incident beams, which leads to an improvement of the optical resolution. A phenomenological interpretation of the nonlinear fluorescence process that offers estimation of signal properties is provided with rate equations. The proposed method is demonstrated to provide the scalability of the optical resolution.
Superresolution fluorescence microscopy techniques beat the diffraction limit, enabling ultra-high resolution imaging in biological physics and nanoscience. In all cases that have been studied experimentally, the resolution scales inversely with the square root of some parameter that measures the number of photons used. However, this ubiquitous limit arises from very distinct mechanisms in different approaches, raising the question of whether it is a fundamental limit that cannot be exceeded, or merely a coincidence of the techniques studied thus far. We demonstrate that, under very general assumptions that encompass essentially all fluorescence microscopy situations, the known resolution limit is indeed universal. Our model considers experiments that build up an image via any arbitrary sequence of steps compatible with our assumptions of (1) light that exhibits shot noise and (2) molecules that can be modeled with rate equations. A detailed examination of our assumptions shows that exceeding this resolution limit will require the use of quantum optical effects, pointing to an avenue for future innovation.