Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)

Study of Cryocooler-based HTS SQUID Cooling System Involving an Infrared Temperature Controller

Souichiro IWAO, Yoshimi Hatsukade, Saburo Tanaka

Published Jan 1, 2005• 0 citations
Publisher

Abstract

A high-Tc superconducting quantum interference device(HTS SQUID)cooling system was developed based on a pulse-tube cryocooler (PTC) and a novel temperature controller. In this system, the temperature controller uses infrared irradiation instead of the commonly employed electric heater to provide accurate and low-noise performances. The infrared light was irradiated via a fiber-optic cable onto a SQUID-mount stage, where a HTS SQUID was cooled to approximately 77 K by the PTC. The output of the irradiation source was controlled with a feedback scheme while monitoring the temperature of the SQUID-mount stage. The temperature of the stage was stabilized at 77 K, and kept within ±0.03 K deviation, for more than 2 hr by the temperature controller. The measured magnetic flux noise of the HTS SQUID magnetometer in the cooling system with the temperature controller showed little magnetic influence due to infrared irradiation.

DOI
10.2221/jcsj.40.300

Related papers

HTS Josephson heterodyne oscillator on a pulse-tube cryocooler

Jia Du, J.C. Macfarlane, S H K Lam +1 more

A high-temperature superconducting (HTS) Josephson heterodyne oscillator based on step-edge junction technology has recently been developed (Du et al 2008 Appl. Phys. Lett. 93 033507, Macfarlane et al 2009 IEEE Trans. Appl. Supercond. 19 920). In this work, the implementation and characterization of such a heterodyne oscillator on a compact pulse-tube cryocooler (PTC) are presented. The rf performance of the oscillator cooled by the cryocooler is compared to that of the same device when cooled in the quiet gas phase of a liquid helium Dewar. Any measurable influence of additional electromagnetic noise and mechanical vibration of the cryocooler on the oscillator performance is assessed by measuring the linewidth broadening of the heterodyne oscillation. The cryocooled oscillator demonstrated excellent performance and negligible excess noise was observed when operating the PTC.

Superconductor Science and Technology•Sep 16, 2009•20 citations

High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier

Dongfeng He, M. Tachiki, Hideo Itozaki

A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.

Review of Scientific Instruments•Jun 1, 2006•0 citations

A high-temperature superconducting millimeter wave detecting system based on pulse tube cryocooler

Jian Chen, Peiheng Wu, Kensuke Nakajima +1 more

A millimeter (mm) wave broadband video detecting system using high temperature superconducting (HTS) junction and compact pulse tube cryocooler (PTC) has been studied. The lowest attainable temperature of the PTC is 42K and the operating temperature (T) can be adjusted by changing the pressure difference in the compressor. By measuring the linewidth of the Josephson oscillation as well as the dynamic range of the Josephson detector, it is found that the PTC has no excess noise compared with other kinds of cryostats such as liquid helium cryostats, and is very suitable for the applications in the mm wave detecting system. Furthermore, to improve the sensitivity of the system, the coupling efficiency of the system has been studied in detail. It is found that the coupling efficiency increases with the increase of RN linearly, and is better than 1% for RN of 1.7 Ohm. A sensitivity of about 318V/W has been obtained for the system based on the PTC and a junction with RN=1.7 Ohm and ICRN =1mV.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 2004•0 citations

Characterization of the low-frequency noise in high-temperature radio frequency superconducting quantum interference devices cooled in static magnetic fields

J. Borgmann, P. David, Raphael Otto +2 more

We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.

Applied Physics Letters•Feb 15, 1999•2 citations

Microwave Stabilization of a HEB Mixer in a Pulse-Tube Cryocooler

Alexander Shurakov, Edward Tong, R. Blundell +3 more

We report the results of our study of the stability of an 800 GHz hot electron bolometer (HEB) mixer cooled with a pulse-tube cryocooler. Pulse-tube cryocoolers introduce temperature fluctuations as well as mechanical vibrations at a frequency of$\sim$1 Hz, both of which can cause receiver gain fluctuations at that frequency. In our system, the motor of the cryocooler was separated from the cryostat to minimize mechanical vibrations, leaving thermal effects as the dominant source of the receiver gain fluctuations. We measured root mean square temperature variations of the 4 K stage of$\sim$7 mK. The HEB mixer was pumped by a solid state local oscillator at 810 GHz. The root mean square current fluctuations at the low noise operating point (1.50 mV, 56.5$\mu\hbox{A}$) were$\sim 0.12\ \mu\hbox{A}$, and were predominantly due to thermal fluctuations. To stabilize the bias current, microwave radiation was injected to the HEB mixer. The injected power level was set by a proportional-integral-derivative controller, which completely compensates for the bias current oscillations induced by the pulse-tube cryocooler. Significant improvement in the Allan variance of the receiver output power was obtained, and an Allan time of 5 s was measured.

IEEE Transactions on Applied Superconductivity•Jan 21, 2013•4 citations

High-Speed Operation of HTS SQUID-Array Interface Circuits With a Cryocooler

Masahiro Horibe, Y. Tarutani, K. Tanabe

The authors evaluated the operation of high-temperature superconducting quantum interference device (SQUID)-array interface circuits (IFCs) with normal-metal control lines. Transimpedance amplification was obtained at an operating speed of 1 Gb/s using a cryocooler. The effect of the number of SQUIDs connected in series and the number of arrays connected in parallel on the level of output from the SQUID-array IFCs was examined by Josephson circuit simulation, and then the effect of statistical spreads of junction characteristics was evaluated by Monte Carlo simulation. It was found that the configuration of two parallel SQUID arrays with 64 SQUIDs gives the highest output when the junction characteristics in the arrays have a certain spread. The authors fabricated the IFCs by using the conventional interface-engineered junction process. The process reproducibility was 100 /spl mu/A /spl plusmn/25% for junction I/sub c/, and 3.02 pH /spl plusmn/5% and 2.57 pH /spl plusmn/17% for the sheet inductance of the upper and lower electrodes, respectively. The transimpedance at low frequencies reached 20 and 4 V/A for input levels of 20 and 100 /spl mu/A, respectively. Output voltages as high as 4.4 mV at 4.2 K and 2.3 mV at 40 K were obtained. Furthermore, an output voltage of 600 /spl mu/V was obtained for a 1-Gb/s 2/sup 15/-1 pseudo-random binary signal input at 40 K.

IEEE Transactions on Applied Superconductivity•Mar 1, 2004•1 citation
A high-Tc superconducting quantum interference device(HTS SQUID)cooling system was developed based on a pulse-tube cryocooler (PTC) and a novel temperature controller. In this system, the temperature controller uses infrared irradiation instead of the commonly employed electric heater to provide accurate and low-noise performances. The infrared light was irradiated via a fiber-optic cable onto a SQUID-mount stage, where a HTS SQUID was cooled to approximately 77 K by the PTC. The output of the irradiation source was controlled with a feedback scheme while monitoring the temperature of the SQUID-mount stage. The temperature of the stage was stabilized at 77 K, and kept within ±0.03 K deviation, for more than 2 hr by the temperature controller. The measured magnetic flux noise of the HTS SQUID magnetometer in the cooling system with the temperature controller showed little magnetic influence due to infrared irradiation.
A high-temperature superconducting (HTS) Josephson heterodyne oscillator based on step-edge junction technology has recently been developed (Du et al 2008 Appl. Phys. Lett. 93 033507, Macfarlane et al 2009 IEEE Trans. Appl. Supercond. 19 920). In this work, the implementation and characterization of such a heterodyne oscillator on a compact pulse-tube cryocooler (PTC) are presented. The rf performance of the oscillator cooled by the cryocooler is compared to that of the same device when cooled in the quiet gas phase of a liquid helium Dewar. Any measurable influence of additional electromagnetic noise and mechanical vibration of the cryocooler on the oscillator performance is assessed by measuring the linewidth broadening of the heterodyne oscillation. The cryocooled oscillator demonstrated excellent performance and negligible excess noise was observed when operating the PTC.
A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.
A millimeter (mm) wave broadband video detecting system using high temperature superconducting (HTS) junction and compact pulse tube cryocooler (PTC) has been studied. The lowest attainable temperature of the PTC is 42K and the operating temperature (T) can be adjusted by changing the pressure difference in the compressor. By measuring the linewidth of the Josephson oscillation as well as the dynamic range of the Josephson detector, it is found that the PTC has no excess noise compared with other kinds of cryostats such as liquid helium cryostats, and is very suitable for the applications in the mm wave detecting system. Furthermore, to improve the sensitivity of the system, the coupling efficiency of the system has been studied in detail. It is found that the coupling efficiency increases with the increase of RN linearly, and is better than 1% for RN of 1.7 Ohm. A sensitivity of about 318V/W has been obtained for the system based on the PTC and a junction with RN=1.7 Ohm and ICRN =1mV.
We have performed a study of the low-frequency noise in high-temperature radio frequency (rf) superconducting quantum interference devices (SQUIDs) cooled in static magnetic fields. At 77 K, the noise of different thin-film YB2C3O7−x washer rf SQUIDs was measured in static magnetic fields up to 55 μT. The SQUID inductances ranged from 150 to 300 pH. The measured low-frequency flux noise of the SQUIDs SΦ1/2 at 1 Hz was between 70 and 350 μΦ0/√Hz, and in terms of magnetic field noise SB1/2 between 120 and 1100 fT/√Hz. The low-frequency noise of all devices at 1 Hz showed no significant increase for all applied static fields.
We report the results of our study of the stability of an 800 GHz hot electron bolometer (HEB) mixer cooled with a pulse-tube cryocooler. Pulse-tube cryocoolers introduce temperature fluctuations as well as mechanical vibrations at a frequency of$\sim1Hz,bothofwhichcancausereceivergainfluctuationsatthatfrequency.Inoursystem,themotorofthecryocoolerwasseparatedfromthecryostattominimizemechanicalvibrations,leavingthermaleffectsasthedominantsourceofthereceivergainfluctuations.Wemeasuredrootmeansquaretemperaturevariationsofthe4Kstageof1 Hz, both of which can cause receiver gain fluctuations at that frequency. In our system, the motor of the cryocooler was separated from the cryostat to minimize mechanical vibrations, leaving thermal effects as the dominant source of the receiver gain fluctuations. We measured root mean square temperature variations of the 4 K stage of1Hz,bothofwhichcancausereceivergainfluctuationsatthatfrequency.Inoursystem,themotorofthecryocoolerwasseparatedfromthecryostattominimizemechanicalvibrations,leavingthermaleffectsasthedominantsourceofthereceivergainfluctuations.Wemeasuredrootmeansquaretemperaturevariationsofthe4Kstageof\sim7mK.TheHEBmixerwaspumpedbyasolidstatelocaloscillatorat810GHz.Therootmeansquarecurrentfluctuationsatthelownoiseoperatingpoint(1.50mV,56.57 mK. The HEB mixer was pumped by a solid state local oscillator at 810 GHz. The root mean square current fluctuations at the low noise operating point (1.50 mV, 56.57mK.TheHEBmixerwaspumpedbyasolidstatelocaloscillatorat810GHz.Therootmeansquarecurrentfluctuationsatthelownoiseoperatingpoint(1.50mV,56.5\mu\hbox{A})were) were)were\sim 0.12\ \mu\hbox{A}$, and were predominantly due to thermal fluctuations. To stabilize the bias current, microwave radiation was injected to the HEB mixer. The injected power level was set by a proportional-integral-derivative controller, which completely compensates for the bias current oscillations induced by the pulse-tube cryocooler. Significant improvement in the Allan variance of the receiver output power was obtained, and an Allan time of 5 s was measured.
The authors evaluated the operation of high-temperature superconducting quantum interference device (SQUID)-array interface circuits (IFCs) with normal-metal control lines. Transimpedance amplification was obtained at an operating speed of 1 Gb/s using a cryocooler. The effect of the number of SQUIDs connected in series and the number of arrays connected in parallel on the level of output from the SQUID-array IFCs was examined by Josephson circuit simulation, and then the effect of statistical spreads of junction characteristics was evaluated by Monte Carlo simulation. It was found that the configuration of two parallel SQUID arrays with 64 SQUIDs gives the highest output when the junction characteristics in the arrays have a certain spread. The authors fabricated the IFCs by using the conventional interface-engineered junction process. The process reproducibility was 100 /spl mu/A /spl plusmn/25% for junction I/sub c/, and 3.02 pH /spl plusmn/5% and 2.57 pH /spl plusmn/17% for the sheet inductance of the upper and lower electrodes, respectively. The transimpedance at low frequencies reached 20 and 4 V/A for input levels of 20 and 100 /spl mu/A, respectively. Output voltages as high as 4.4 mV at 4.2 K and 2.3 mV at 40 K were obtained. Furthermore, an output voltage of 600 /spl mu/V was obtained for a 1-Gb/s 2/sup 15/-1 pseudo-random binary signal input at 40 K.