The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting

Entanglement measurement in a Cavity QED System

M. L. Terraciano, Rebecca Olson Knell, D. G. Norris, Jietai Jing, Luis A. Orozco, James Clemens, Perry R. Rice

Published Jan 1, 2007• 0 citations
Publisher

Abstract

We measure an entanglement witness of a cavity QED system with the cross correlation of its orthogonal modes. The driven mode has information about the field, while the nondriven about the atom through spontaneous emission.
DOI
10.1364/cqo.2007.cmi17

Related papers

Cross-correlations and entanglement in a cavity QED system

M. L. Terraciano, R. Olson, D. G. Norris +4 more

We measure the cross-correlation between transmitted light out of a cavity QED system and spontaneous emission into the orthogonal polarization cavity mode. The result is an entanglement witness between the two modes of the cavity.

Quantum Electronics and Laser Science Conference•May 1, 2007•0 citations

Entanglement in a Cavity QED system with a multi-level atom in a weakly driven two-mode cavity

James Clemens, Perry R. Rice, R. Olson +2 more

For a 4-level atom in a weakly driven 2-mode cavity, we explore the entanglement between the atom, and the field modes. We explore the relation between various cross-correlation functions and the usual measures of entanglement.

Frontiers in Optics•Jan 1, 2006•0 citations

Steady State Entanglement in Cavity QED

P. R. Rice, J. Gea-Banacloche, M. L. Terraciano +2 more

We investigate steady state entanglement in an open quantum system, specifically a single atom in a driven optical cavity with cavity loss and spontaneous emission. The system reaches a steady pure state when driven very weakly. Under these conditions, there is an optimal value for atom-field coupling to maximize entanglement, as larger coupling favors a loss port due to the cavity enhanced spontaneous emission. We address ways to implement measurements of the entanglement and find that normalized cross-correlation functions are indicators of the entanglement in the system. The equal time intensity-field cross correlation between the transmitted field of the cavity and the fluorescence intensity is proportional to the entanglement of formation for weak driving fields.

arXiv:quant-ph/0601208•Optics Express•Jan 1, 2006•22 citations

Correlation Functions and Multipartite Entanglement in Cavity QED

Perry R. Rice, James Clemens, Luis A. Orozco +3 more

We consider the entanglement between a multi-level atom and two cavity modes for a cavity QED system, find that cross-correlations between the two modes are witness to atom-field entanglement. Concurrences and log negativities are also calculated.

The Rochester Conferences on Coherence and Quantum Optics and the Quantum Information and Measurement meeting•Jan 1, 2007•0 citations

Multipartite atom(s)-field entanglement in cavity QED

Perry R. Rice, James Clemens, Luis A. Orozco

We consider the entanglement between a multi-level atom and two cavity modes for a cavity QED system, find that cross-correlations between the two modes are witness to atom-field entanglement. Concurrences and log negativities are also calculated.

Quantum Electronics and Laser Science Conference•May 1, 2007•0 citations

Cross-correlations and Entanglement in Cavity QED

Matthew L. Terraciano

Every quantum system subjected to measurements is an open quantum system. The cavity QED system is elegant in that it probes the interaction between two quantum systems, the atom and the field, while its loss mechanisms are well understood and can be externally monitored. The study of cross-correlations in cavity QED is important for understanding how entanglement evolves in open quantum systems. As quantum information science grows we need to learn more about entanglement and how it can be quantified and measured. Correlation functions have been used to compare an electromagnetic field (intensity) of one mode with the electromagnetic field (intensity) of the same mode at a later time or different spatial location. In quantum optics, correlation functions have been calculated and measured to probe the nonclassical field that results from the interaction of a single mode of the electromagnetic field and an ensemble of two-level atoms (the canonical cavity QED system). This field can exhibit antibunching, squeezing, and can violate inequalities required for a classical field. Entanglement in the steady state of a cavity QED system cannot be measured directly with traditional correlation functions (Hanbury-Brown and Twiss type experiments). Cross-correlations, however, interrogate directly both modes of the entangled pair, the transmitted (cavity) and the fluorescent (atom) intensities, and can act as an entanglement witness. This thesis presents the implementation of a cross-correlation measurement in a cavity QED system. The work has required the construction of an apparatus that incorporates laser cooling and trapping with quantum optics to carefully control both the external (center of mass motion) and internal (atomic state) degrees of freedom of a collection of atoms that interact with a single mode of a high finesse Fabry-Perot cavity. We examine theoretically and experimentally a new intensity cross-correlation function which probes the evolution of the cavity field conditioned on the detection of a fluorescent photon from an atom in the cavity. The results open the possibility to generalize the dynamics of entanglement as a physical resource necessary for the nascent quantum information science.

•Jun 30, 2006•0 citations
We investigate steady state entanglement in an open quantum system, specifically a single atom in a driven optical cavity with cavity loss and spontaneous emission. The system reaches a steady pure state when driven very weakly. Under these conditions, there is an optimal value for atom-field coupling to maximize entanglement, as larger coupling favors a loss port due to the cavity enhanced spontaneous emission. We address ways to implement measurements of the entanglement and find that normalized cross-correlation functions are indicators of the entanglement in the system. The equal time intensity-field cross correlation between the transmitted field of the cavity and the fluorescence intensity is proportional to the entanglement of formation for weak driving fields.
Every quantum system subjected to measurements is an open quantum system. The cavity QED system is elegant in that it probes the interaction between two quantum systems, the atom and the field, while its loss mechanisms are well understood and can be externally monitored. The study of cross-correlations in cavity QED is important for understanding how entanglement evolves in open quantum systems. As quantum information science grows we need to learn more about entanglement and how it can be quantified and measured. Correlation functions have been used to compare an electromagnetic field (intensity) of one mode with the electromagnetic field (intensity) of the same mode at a later time or different spatial location. In quantum optics, correlation functions have been calculated and measured to probe the nonclassical field that results from the interaction of a single mode of the electromagnetic field and an ensemble of two-level atoms (the canonical cavity QED system). This field can exhibit antibunching, squeezing, and can violate inequalities required for a classical field. Entanglement in the steady state of a cavity QED system cannot be measured directly with traditional correlation functions (Hanbury-Brown and Twiss type experiments). Cross-correlations, however, interrogate directly both modes of the entangled pair, the transmitted (cavity) and the fluorescent (atom) intensities, and can act as an entanglement witness. This thesis presents the implementation of a cross-correlation measurement in a cavity QED system. The work has required the construction of an apparatus that incorporates laser cooling and trapping with quantum optics to carefully control both the external (center of mass motion) and internal (atomic state) degrees of freedom of a collection of atoms that interact with a single mode of a high finesse Fabry-Perot cavity. We examine theoretically and experimentally a new intensity cross-correlation function which probes the evolution of the cavity field conditioned on the detection of a fluorescent photon from an atom in the cavity. The results open the possibility to generalize the dynamics of entanglement as a physical resource necessary for the nascent quantum information science.