European Frequency and Time Forum

Fountain clock accuracy

Kurt Gibble

Published Apr 1, 2012• 6 citations
Publisher

Abstract

We give a review of recent advances in the accuracy of atomic fountain clocks. The new features are improved experimental and theoretical treatments of distributed cavity phase shifts and a full modeling of microwave lensing. Here we highlight that state selection is often highly non-uniform when Rabi flopping is used instead of an interrupted adiabatic frequency chirp. We show that detuning the state-selection microwave field as well as changing its amplitude can give a much more homogeneous state selection. A spatially inhomogeneous state selection corrupts the density extrapolation because the density distribution changes, which also mixes effects from distributed cavity phase and microwave lensing. This is expected to be important for the microgravity clock PHARAO on ACES, and can also improve fountain clocks.

DOI
10.1109/eftf.2012.6502323

Related papers

Distributed cavity phase and the associated power dependence

Ruoxin Li, Kurt Gibble

We discuss the power dependence of distributed cavity phase errors for cylindrical TE011cavities in laser-cooled atomic fountain clocks. The azimuthally symmetric phase variations produce a surprisingly large distributed cavity phase error for two 2pi, 4pi, and 6pi pulses. This is due to the correlation between the transverse variation of the Rabi frequency over the cavity aperture and a quadratic density variation of the atomic sample, along with the symmetry of the longitudinal phase variation in the cavity. We show that the large azimuthally symmetric fields and phase shifts near the walls of the endcap holes produce very small errors at optimal power for a uniform wall resistance. We also show the power variation for higher order azimuthal variations m=1, 2, and 4. These may be caused by fountain tilts, nonuniform detection of atoms, and asymmetries in the laser trapping and cooling of the atoms. We demonstrate that distributed cavity phase errors in physical cavities may have no variation with the microwave power. A combination of rigorous calculations of cavity losses, measurements of power dependence, the atomic distributions, and fountain tilts, and electrical measurements that show the lower limit of the cavity Q and the cavity symmetry, should provide stringent limits on distributed cavity phase errors for current atomic clocks

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jan 18, 2006•9 citations

ATOMIC CLOCKS AND COLD ATOM SCATTERING

Chad Fertig, Ronald Legere, J. IRFON REES +3 more

We demonstrate a Rb fountain clock which has a small cold collision shift that is cancelled by detuning the microwave cavity. To further enhance the stability and accuracy, we are currently developing a new state detection technique that directly measures population differences and are juggling atoms in the fountain. Fountain clocks also enable a novel quantum atom-optics precision scattering measurement.

Laser Spectroscopy•Jun 1, 2002•1 citation

Atomic Fountain Microwave Clock.

Steven Chu

Abstract : The grant as in support of a research program to explore the possibility of a microwave atomic clock based on an atomic fountain of cesium atoms. During the two year granting period, the following work was done: A large magneto-optic trap in a vapor cell was constructed where over 4x 10(exp 10) atoms were trapped at a density on the order of 10(exp 11) atoms/cu cm. This work increased the number of atoms optically trapped by a factor of -400 compared to previous work. The optical density of the atoms in this trap has a peak attenuation of e(-175). In an invited review article we examined the prospects for slow atom frequency standards. Most of the systematic effects that limit the current accuracy today's frequency standards decrease as the velocity of the atoms is reduced. We identified the one possible exception: collisions between ultra-cold atom in an atomic fountain could induce a phase shift that would ultimately limit the accuracy of the fountain clock. We brought the problem to the attention of B. Verhaar, who began a series of calculations on the effects of low energy collisions. jg p.4

•Jul 7, 1994•0 citations

Beyond Fountain

Jingbiao Chen, Xiaoji Zhou, Xuzong Chen

Our recent work showed the atomic microwave clock configuration beyond fountain is possible by trapped Rb or Cs atoms in optical lattice formed by trapping laser operating at magic wavelength for microwave clock transition where light shifts on both clock levels are matching exactly, and an accuracy of 2 times 10-17at this clock configuration is expected. In this report, we analyze the possibility of 20 s coherent interrogation time of stable Rb or Cs clock transition, which corresponds to a 2 km height atomic fountain. We propose a simple experimental scheme to measure the needed magic wavelengths for atomic microwave clocks in conventional fountain configuration. Moreover, we discuss a new clock scheme combining fountain and lattice configurations, thus provide an easy way to improve fountain clock performance by adding a trapping laser beam in conventional fountain system without any further complicated modifications

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jun 1, 2006•0 citations

Juggling atomic clocks

Chad Fertig, Kurt Gibble

We demonstrate a prototype of a laser-cooled 87Rb fountain clock and measure the frequency shift due to cold collisions. The shift is 30 times smaller than that in a laser-cooled Cs clock. We observe a density dependent pulling by the microwave cavity and use it to cancel the collision shift. We have also demonstrated a juggling atomic fountain to study cold collisions and we discuss the importance ofjuggling for future fountain clocks.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Dec 15, 2000•0 citations

A juggling fountain clock and distributed cavity phase shifts

Chad Fertig, Ruoxin Li, J. Irfon Rees +1 more

We have demonstrated a juggling /sup 87/Rb fountain clock. The juggling frequency shift is a particularly interesting measurement. We expect to report measurements of the Ramsey fringe contrast and a comparison to calculations that include photon recoils. We will also present results of calculations of distributed cavity phase shifts.

Conference on Precision Electromagnetic Measurements•Jun 25, 2003•0 citations
We give a review of recent advances in the accuracy of atomic fountain clocks. The new features are improved experimental and theoretical treatments of distributed cavity phase shifts and a full modeling of microwave lensing. Here we highlight that state selection is often highly non-uniform when Rabi flopping is used instead of an interrupted adiabatic frequency chirp. We show that detuning the state-selection microwave field as well as changing its amplitude can give a much more homogeneous state selection. A spatially inhomogeneous state selection corrupts the density extrapolation because the density distribution changes, which also mixes effects from distributed cavity phase and microwave lensing. This is expected to be important for the microgravity clock PHARAO on ACES, and can also improve fountain clocks.
We discuss the power dependence of distributed cavity phase errors for cylindrical TE011cavities in laser-cooled atomic fountain clocks. The azimuthally symmetric phase variations produce a surprisingly large distributed cavity phase error for two 2pi, 4pi, and 6pi pulses. This is due to the correlation between the transverse variation of the Rabi frequency over the cavity aperture and a quadratic density variation of the atomic sample, along with the symmetry of the longitudinal phase variation in the cavity. We show that the large azimuthally symmetric fields and phase shifts near the walls of the endcap holes produce very small errors at optimal power for a uniform wall resistance. We also show the power variation for higher order azimuthal variations m=1, 2, and 4. These may be caused by fountain tilts, nonuniform detection of atoms, and asymmetries in the laser trapping and cooling of the atoms. We demonstrate that distributed cavity phase errors in physical cavities may have no variation with the microwave power. A combination of rigorous calculations of cavity losses, measurements of power dependence, the atomic distributions, and fountain tilts, and electrical measurements that show the lower limit of the cavity Q and the cavity symmetry, should provide stringent limits on distributed cavity phase errors for current atomic clocks
Abstract : The grant as in support of a research program to explore the possibility of a microwave atomic clock based on an atomic fountain of cesium atoms. During the two year granting period, the following work was done: A large magneto-optic trap in a vapor cell was constructed where over 4x 10(exp 10) atoms were trapped at a density on the order of 10(exp 11) atoms/cu cm. This work increased the number of atoms optically trapped by a factor of -400 compared to previous work. The optical density of the atoms in this trap has a peak attenuation of e(-175). In an invited review article we examined the prospects for slow atom frequency standards. Most of the systematic effects that limit the current accuracy today's frequency standards decrease as the velocity of the atoms is reduced. We identified the one possible exception: collisions between ultra-cold atom in an atomic fountain could induce a phase shift that would ultimately limit the accuracy of the fountain clock. We brought the problem to the attention of B. Verhaar, who began a series of calculations on the effects of low energy collisions. jg p.4
Our recent work showed the atomic microwave clock configuration beyond fountain is possible by trapped Rb or Cs atoms in optical lattice formed by trapping laser operating at magic wavelength for microwave clock transition where light shifts on both clock levels are matching exactly, and an accuracy of 2 times 10-17at this clock configuration is expected. In this report, we analyze the possibility of 20 s coherent interrogation time of stable Rb or Cs clock transition, which corresponds to a 2 km height atomic fountain. We propose a simple experimental scheme to measure the needed magic wavelengths for atomic microwave clocks in conventional fountain configuration. Moreover, we discuss a new clock scheme combining fountain and lattice configurations, thus provide an easy way to improve fountain clock performance by adding a trapping laser beam in conventional fountain system without any further complicated modifications